Slicer Registration Library Case #49: Pediatric Brain DTI

Input

this is the fixed DTI FA image. We want to align all images into this space
this is associated B0 image. Aligned with FA. Will use this as registration reference (fixed image)
RegArrow NonRigid.png
this is the moving MR image, to be aligned with the reference on the left
this is the moving MR image, to be aligned with the reference on the left
fixed image/target
DTI (FA)
fixed image/target
DTI (B0)
moving image
T2 MRI
moving image
T1 MRI

Description

Goal is to align the structural T1 and T2 images with the DTI. Particularly the T1, which is associated with additional atlas/segmentation data (not shown). The DTI has strong distortions typical for EPI acquisitions. Note that the T1 image had "defacing" applied for anonymization, but the brain portion of the image is unaffected.
Approach: Because the T2 matches the B0 contrast better than the T1, we will use the T2 as registration target. We will then register the T1 to the T2 and finally to the B0. Since the DTI contains strong distortions, a nonrigid registration is necessary. Workflow:

  1. affine register T2-B0
  2. BSpline register T2-B0, using the above affine as starting point
  3. affine register T1-T2. Apply transform without resampling
  4. resample T1 with nonrigid transform obtained for the T2.

Modules used

Download (from NAMIC MIDAS)

Why 2 sets of files? The "input data" mrb includes only the unregistered data to try the method yourself from start to finish. The full dataset includes intermediate files and results (transforms, resampled images etc.). If you use the full dataset we recommend to choose different names for the images/results you create yourself to distinguish the old data from the new one you generated yourself.

Keywords

MRI, pediatric, brain, intra-subject, diffusion MRI, DWI, DTI

Video Screencasts

  1. RegLib_C49 Registration Screencast (start-finish)

Procedure

  1. Prepare Masks: see also movie above
    1. two masks for the B0 and T2 are already provided with the dataset. For examples on how to obtain masks quickly from your image data see:
    2. We will use these masks for the registration. To ensure sufficient points outside the brain surface can participate in the registration, we dilate the two masks slightly to extend beyond the brain:
    3. go to the Documentation/Nightly/Modules/Editor ''Editor'' module
    4. Master Volume: T2
    5. Merge Volume: T2_mask
    6. click on the Dilation Tool. Set label to 1. Ensure T2_mask is visible in the slice views
    7. click on the "Dilate" button once. You should see the boundary expand. Because there is little interstitial space/cortical CSF, we dilate only little to avoid including the skull in the ROI.
    8. switch MergeVolume to B0 and the Merge Volume to B0_mask
    9. again select the Dilate tool and click "Dilate" 2-3 times. We can afford to dilate more here since the skull is very dark in the B0.
  2. Affine Register T2-B0
    1. go to the General Registration (BRAINS) module
    2. Input Images: Fixed Image Volume: B0
    3. Input Images: Moving Image Volume: T2
    4. Output Settings:
      1. Slicer Linear Transform (create new transform, rename to: "Xf1_T2-B0_Affine")
      2. Output Image Volume none. No resampling required for linear transforms
    5. Registration Phases: select/check Rigid , Rigid+Scale, Affine
    6. Main Parameters:
      1. increase Number Of Samples to 300,000
    7. Mask Option: select ROI button
      1. Masking input fixed: select B0_mask
      2. Masking input moving: select T2_mask
    8. Leave all other settings at default
    9. click: Apply; runtime < 1 min.
  3. BSpline Register T2-B0
    1. leave B0 and T2 as fixed and moving volumes
    2. Output Settings:
      1. Slicer Linear Transform select None
      2. Slicer BSpline Transform create new, rename to "Xf2_T2-B0_BSpline" or similar
      3. Output Image Volume: create new and rename to "T2_Xf2". Resampling is required for nonrigid transforms.
    3. Registration Phases: unchheck Rigid , Rigid+Scale, Affine and check "BSpline" only
    4. Main Parameters:
      1. increase Number Of Samples to at least 300,000
      2. BSpline Grid Size: set to 10,10,5 or similar. Note we have lower resolution in the z-direction, hence we reduce the grid size there.
      3. leave masking settings as before
    5. click: Apply; runtime < 3 min.
    6. we now have the T2 aligned with the DTI. Place T2_Xf2 and B0 in the foreground and background and use the fade slider to view the result
  4. Affine Register T1-T2
    1. go to the General Registration (BRAINS) module
    2. Input Images: Fixed Image Volume: T2
    3. Input Images: Moving Image Volume: T1
    4. Output Settings:
      1. Slicer Linear Transform (create new transform, rename to: "Xf3_T1-T2_Affine")
      2. Output Image Volume none. No resampling required for linear transforms
    5. Registration Phases: select/check Rigid , Rigid+Scale, Affine
    6. Main Parameters:
      1. Number Of Samples to 300,000
    7. Mask Option: select "NOMASK" button
      1. Masking input fixed: select "None"
      2. Masking input moving: select "None"
    8. Leave all other settings at default
    9. click: Apply; runtime < 1 min.
    10. verify the alignment in the Slice views
    11. go to the Data module, note that the T1 has been placed inside the Xf3 transform.
    12. right click on the T1 image inside the transform. From the pop-up menu select Harden Transform. You should see the T1 node move back out to the main hierarchy level. You have now applied the new orientation to the T1 image, so we rename it to document that change:
    13. double click on T1 node, change name to "T1_Xf3" or similar
    14. we now have the T1 aligned with the T2. We can therefore apply the same transform "Xf2_T2-B0_BSpline" from above to the T1:
  5. Resample T1:
    1. Go to the Registration/Resample Image (BRAINS) module
      1. Image To Warp: T1_Xf3
      2. Reference Image: T2_Xf2 or B0
      3. Output Image: create new and rename to "T1_Xf3_Xf2" or similar
      4. Pixel Type: set to short
      5. Warping Parameters / Transform file: select "Xf2_T2-B0_BSpline"
      6. Interpolation Mode: select linear or WindowedSinc
    2. click Apply.
    3. we now have all images in the same orientation as the B0.

Registration Results

RegLib C49 unregistered.gif MR/CT before registration (click to enlarge)
RegLib C49 registered1 T2B0.gif alignment of T2 to B0 (click to enlarge)
RegLib C49 registered2 T1T2.gif preliminary affine alignment of T1 to T2 (click to enlarge)
RegLib C49 registered3 T1B0.gif final alignment of T1 to B0 (click to enlarge)

Acknowledgments

Many thanks to Mojdeh Zamyadi and Dr. E. Widjaja's lab from the Hospital for Sick Children in Toronto, Canada, for sharing the example data.