Main Page/SlicerCommunity/2020

From Slicer Wiki
Jump to: navigation, search
Home < Main Page < SlicerCommunity < 2020

Go to 2022 :: 2021 :: 2020 :: 2019 :: 2018 :: 2017 :: 2016 :: 2015 :: 2014-2011 :: 2010-2000



The community that relies on 3D Slicer is large and active: (numbers below updated on December 1st, 2023)

  • 2,147+ papers on PubMed citing the Slicer platform paper
    • Fedorov A., Beichel R., Kalpathy-Cramer J., Finet J., Fillion-Robin J-C., Pujol S., Bauer C., Jennings D., Fennessy F.M., Sonka M., Buatti J., Aylward S.R., Miller J.V., Pieper S., Kikinis R. 3D Slicer as an Image Computing Platform for the Quantitative Imaging Network. Magnetic Resonance Imaging. 2012 Nov;30(9):1323-41. PMID: 22770690. PMCID: PMC3466397.


The following is a sample of the research performed using 3D Slicer outside of the group that develops it. in 2020

We monitor PubMed and related databases to update these lists, but if you know of other research related to the Slicer community that should be included here please email: marianna (at) bwh.harvard.edu.

Contents

2020

Quantitative Chest CT Analysis in COVID-19 to Predict the Need for Oxygenation Support and Intubation

Publication: Eur Radiol. 2020 Dec;30(12):6770-8. PMID: 32591888 | PDF


Authors: Lanza E, Muglia R, Bolengo I, Santonocito OG, Lisi C, Angelotti G, Morandini P, Savevski V, Politi LS, Balzarini L.

Institution: Department of Diagnostic and Interventional Radiology, Humanitas Clinical and Research Center - IRCCS, Milan, Italy.

Abstract: We performed a single-centre retrospective study on COVID-19 patients hospitalised from January 25, 2020, to April 28, 2020, who received CT at admission prompted by respiratory symptoms such as dyspnea or desaturation. QCT was performed using a semi-automated method (3D Slicer). Lungs were divided by Hounsfield unit intervals. Compromised lung (%CL) volume was the sum of poorly and non-aerated volumes (- 500, 100 HU). We collected patient's clinical data including oxygenation support throughout hospitalisation.

Prospective Analysis Using a Novel CNN Algorithm to Distinguish Atypical Ductal Hyperplasia From Ductal Carcinoma in Situ in Breast

Publication: Clin Breast Cancer. 2020 Dec;20(6):e757-e760. PMID: 32680766 | PDF

Authors: Mutasa S, Chang P, Nemer J, Van Sant EP, Sun M, McIlvride A, Siddique M, Ha R.

Institution: Department of Radiology, Columbia University Medical Center, New York, NY, USA.

Abstract: In this institutional review board-approved study, a new dataset composed of 280 unique mammographic images from 140 patients was used to test our CNN algorithm. All patients underwent stereotactic-guided biopsy of calcifications and underwent surgical excision with available final pathology. The ADH group consisted of 122 images from 61 patients with the highest pathology diagnosis of ADH. The DCIS group consisted of 158 images from 79 patients with the highest pathology diagnosis of DCIS. Two standard mammographic magnification views (craniocaudal and mediolateral/lateromedial) of the calcifications were used for analysis. Calcifications were segmented using an open source software platform 3D Slicer and resized to fit a 128 × 128 pixel bounding box. Our previously developed CNN algorithm was used. Briefly, a 15 hidden layer topology was used. The network architecture contained 5 residual layers and dropout of 0.25 after each convolution. Diagnostic performance metrics were analyzed including sensitivity, specificity, accuracy, and area under the receiver operating characteristic curve. The "positive class" was defined as the pure ADH group in this study and thus specificity represents minimizing the amount of falsely labeled pure ADH cases.

3D Reconstruction of Wilms' Tumor and Kidneys in Children: Variability, Usefulness and Constraints

Publication: J Pediatr Urol. 2020 Dec;16(6):830.e1-830.e8. PMID: 32893166

Authors: Chaussy Y, Vieille L, Lacroix E, Lenoir M, Marie F, Corbat L, Henriet J, Auber F.

Institution: Department of Pediatric Surgery, CHU Besançon, Besançon, France.

Abstract: 14 scans from 12 patients were manually or semi-automatically segmented by 2 teams using 3D Slicer software. Inter-individual variability of 3D reconstructions was measured based on the Dice index. The utility of 3D reconstructions for the surgical planning was evaluated by 4 pediatric surgeons using a 5-point Likert scale. The possibility of undertaking NSS was evaluated according to the criteria defined in the Umbrella SIOP-RTSG 2016 protocol.

Digital Three-Dimensional Visualization of Intrabony Periodontal Defects for Regenerative Surgical Treatment Planning

Publication: BMC Oral Health. 2020 Dec 1;20(1):351. PMID: 33261592 | PDF

Authors: Palkovics D, Mangano FG, Nagy K, Windisch P.

Institution: Department of Periodontology, Semmelweis University, Budapest, Hungary.

Abstract: Four patients with a total of six intrabony periodontal defects were enrolled in the present study. Two months following initial periodontal treatment, a CBCT scan was taken. The novel semi-automatic segmentation method was performed in an open-source medical image processing software, 3D Slicer to acquire virtual 3D models of alveolar and dental structures. Intrasurgical and digital measurements were taken, and results were compared to validate the accuracy of the digital models. Defect characteristics were determined prior to surgery with conventional diagnostic methods and 3D virtual models. Diagnostic assessments were compared to the actual defect morphology during surgery.


Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia

Publication: J Vis Exp. 2020 Dec 19;(166). PMID: 33393515 Authors: Cattabriga A, Cocozza MA, Vara G, Coppola F, Golfieri R.

Institution: Department of Diagnostic and Specialty Medicine, Policlinico Sant'Orsola-Malpighi, University of Bologna, Bologna, Italy.

Abstract: Segmentation is a complex task, faced by radiologists and researchers as radiomics and machine learning grow in potentiality. The process can either be automatic, semi-automatic, or manual, the first often not being sufficiently precise or easily reproducible, and the last being excessively time consuming when involving large districts with high-resolution acquisitions. A high-resolution CT of the chest is composed of hundreds of images, and this makes the manual approach excessively time consuming. Furthermore, the parenchymal alterations require an expert evaluation to be discerned from the normal appearance; thus, a semi-automatic approach to the segmentation process is, to the best of our knowledge, the most suitable when segmenting pneumonias, especially when their features are still unknown. For the studies conducted in our institute on the imaging of COVID-19, we adopted 3D Slicer, a freeware software produced by the Harvard University, and combined the threshold with the paint brush instruments to achieve fast and precise segmentation of aerated lung, ground glass opacities, and consolidations. When facing complex cases, this method still requires a considerable amount of time for proper manual adjustments, but provides an extremely efficient mean to define segments to use for further analysis, such as the calculation of the percentage of the affected lung parenchyma or texture analysis of the ground glass areas.

Feasibility of MRI Radiomics for Predicting KRAS Mutation in Rectal Cancer

Publication: Curr Med Sci. 2020 Dec;40(6):1156-60. PMID: 33428144

Authors: Guo XF, Yang WQ, Yang Q, Yuan ZL, Liu YL, Niu XH, Xu HB.

Institution: Department of Radiology, Zhongnan Hospital of Wuhan University, Wuhan, China.

Abstract: The mutation status of KRAS is a significant biomarker in the prognosis of rectal cancer. This study investigated the feasibility of MRI-based radiomics in predicting the mutation status of KRAS with a composite index which could be an important criterion for KRAS mutation in clinical practice. In this retrospective study, a total of 127 patients with rectal cancer were enrolled. 3D Slicer was used to extract the radiomics features from the MRI images, and sparse support vector machine (SVM) with linear kernel was applied for feature reduction. The radiomics classifier for predicting the KRAS status was then constructed by Linear Discriminant Analysis (LDA) and its performance was evaluated. The composite index was determined with LDA model. Out of 127 rectal cancer subjects, there were 44 KRAS mutation cases and 83 wild cases. A total of 104 radiomics features were extracted, 54 features were filtered by linear SVM with L1-norm regularization and 6 features that had no significant correlations within them were finally selected. The radiomics classifier constructed using the 6 features featured an AUC value of 0.669 (specificity: 0.506; sensitivity: 0.773) with LDA. Furthermore, the composite index (Radscore) had statistically significant difference between the KRAS mutation and wild groups. It is suggested that the MRI-based radiomics has the potential in predicting the KRAS status in patients with rectal cancer, which may enhance the diagnostic value of MRI in rectal cancer.

Using Individualized Three-Dimensional Printed Airway Models to Guide Airway Stent Implantation

Publication: Interact Cardiovasc Thorac Surg. 2020 Dec 7;31(6):900-3. PMID: 33150423

Authors: Xu J, Sullivan C, Ong HX, Williamson JP, Traini D, Hersch N, Byrom M, Young PM.

Institution: Respiratory Technology Group, Woolcock Institute of Medical Research, Sydney, NSW, Australia.

Abstract: Airway stents are used to manage central airway obstructions by restoring airway patency. Current manufactured stents are limited in shape and size, which pose issues in stent fenestrations needed to be manually created to allow collateral ventilation to airway branches. The precise location to place these fenestrations can be difficult to predict based on 2-dimensional computed tomography images. Inspiratory computed tomography scans were obtained from 3 patients and analysed using 3D Slicer™, Blender™ and AutoDesk® Meshmixer™ programmes to obtain working 3D-airway models, which were 3D printed. Stent customizations were made based on 3D-model dimensions, and fenestrations into the stent were cut. The modified stents were then inserted as per usual technique. Two patients reported improved airway performance; however, stents were later removed due to symptoms related to in-stent sputum retention. In a third patient, the stent was removed a few weeks later due to the persistence of fistula leakage. The use of a 3D-printed personalized airway model allowed for more precise stent customization, optimizing stent fit and allowing for cross-ventilation of branching airways. We determine that an airway model is a beneficial tool for stent optimization but does not prevent the development of some stent-related complications such as airway secretions.

A 3D-CT Analysis of Femoral Symmetry-Surgical Implications

Publication: J Clin Med. 2020 Nov 3;9(11):3546. PMID: 33153138 | PDF

Authors: Ferràs-Tarragó J, Sanchis-Alfonso V, Ramírez-Fuentes C, Roselló-Añón A, Baixauli-García F.

Institution: Department of Orthopaedic Surgery, Hospital Universitario y Politécnico La Fe, València, Spain.

Abstract: The 3D biomodel of both femurs was rendered to obtain the volumetric values with the Threshold Effect tool based on the Hounsfield units and using the same value for both femurs, 3D Slicer


Automatic Machine Learning to Differentiate Pediatric Posterior Fossa Tumors on Routine MR Imaging

Publication: Front Surg. 2020 Nov 12;7:587790. PMID: 32661052 | PDF

Authors: Zhou H, Hu R, Tang O, Hu C, Tang L, Chang K, Shen Q, Wu J, Zou B, Xiao B, Boxerman J, Chen W, Huang RY, Yang L, Bai HX, Zhu C.

Institution: Department of Neurology, Xiangya Hospital of Central South University, Changsha, Hunan, China.

Abstract: MR images of all patients were loaded into 3D Slicer software v.4.10, which was used as a user-driven manual active contour-segmentation tool to segment tumor volumes. ROIs were manually drawn section by section on the T2WI, T1WI contrast-enhanced sequence, and ADC images by 2 authors (H.Z., with 7 years of clinical experience in neuroradiology, and L.T., with 5 years of clinical experience in neuroradiology). The ROIs defined in our study include both the enhancing and nonenhancing components of tumor as well as peritumoral edema. On-line Figure 1 shows an example of ROI delineation on a T1WI contrast-enhanced sequence, T2WI, and ADC maps. The intraclass correlation coefficient value was used to assess interobserver reproducibility of generated masks.

3D Slicer and Sina Appilication for Surgical Planning of Giant Invasive Spinal Schwannoma With Scoliosis: A Case Report and Literature Review

Publication: Neurochirurgie. 2020 Nov;66(5):396-399. PMID: 32777234

Authors: Hou X, Yang DD, Li D, Zeng L, Li C.

Institution: School of Clinical Medicine, Chengdu University of TCM, Hospital of Chengdu University of Traditional Chinese Medicine, Chengdu, China.

Abstract: The surgical management of giant invasive spinal schwannomas (GISSs) has been discussed previously, and most cases are treated via the posterior approach. However, when the tumor grows beyond the spine and greatly pushes the surrounding tissues, the combined anterior-posterior approach may be a better choice. However, the anterior approach can be challenging when there is a lack of knowledge regarding the surrounding abdominal structures. Case description: A 67-year-old male suffered from slight scoliosis and an unstable spine due to GISS, which led to a long history of lower back pain and abnormal gait. Here, we report a novel method combining the use of 3D Slicer and the Sina application to help surgeons locate such lesions and better understand the three-dimensional (3D) relationship between the tumor and surrounding tissues. The proposed method promotes complete excision, shortens operation time, and reduces related complications. Conclusion: We recommend using the combination of 3D Slicer and Sina to assist surgeons in handling accurate 3D information of GISS while simultaneously simulating the surgery.

A Novel CNN Algorithm for Pathological Complete Response Prediction Using an I-SPY TRIAL Breast MRI Database

Publication: Magn Reson Imaging. 2020 Nov;73:148-51. PMID: 32889091 | PDF

Authors: Liu MZ, Mutasa S, Chang P, Siddique M, Jambawalikar S, Ha R.

Institution: Department of Medical Physics, Columbia University Medical Center, New York, NY, USA.

Abstract: From the I-SPY TRIAL breast MRI database, 131 patients from 9 institutions were successfully downloaded for analysis. First post-contrast MRI images were used for 3D segmentation using 3D Slicer. Our CNN was implemented entirely of 3 × 3 convolutional kernels and linear layers. The convolutional kernels consisted of 6 residual layers, totaling 12 convolutional layers. Dropout with a 0.5 keep probability and L2 normalization was utilized. Training was implemented by using the Adam optimizer. A 5-fold cross validation was used for performance evaluation. Software code was written in Python using the TensorFlow module on a Linux workstation with one NVidia Titan X GPU.

Funding: R38 CA231577/CA/NCI NIH HHS/United States

Versatile Low-Cost Volumetric 3D Ultrasound Imaging Using Gimbal-Assisted Distance Sensors and an Inertial Measurement Unit

Publication: [https://pubmed.ncbi.nlm.nih.gov/33227915 Sensors (Basel) . 2020 Nov 19;20(22):6613. PMID: 33227915] | PDF

Authors: Kim T, Kang DH, Shim S, Im M, Seo BK, Kim H, Lee BC.

Institution: Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, Korea.

Abstract: The tracked images combined with the ultrasound images and the transformed data were sent from PLUS to the 3D Slicer to observe the movement in real time. The scanning data around the area of interest were recorded to create a meta-image file that contained the sequence, and a 3D volume was then formed using the file via PLUS.


DRRGenerator: A Three-dimensional Slicer Extension for the Rapid and Easy Development of Digitally Reconstructed Radiographs

Publication: J Clin Imaging Sci. 2020 Oct 29;10:69. PMID: 33194311 | PDF

Authors: Czeibert K, Sommese A, Petneházy Ö, Csörgő T, Kubinyi E.

Institution: University of Miami Miller School of Medicine, Miami, FL, USA.

Abstract: As the interest in image-guided medical interventions has increased, so too has the necessity for open-source software tools to provide the required capabilities without exorbitant costs. A common issue encountered in these procedures is the need to compare computed tomography (CT) data with X-ray data, for example, to compare pre-operative CT imaging with intraoperative X-rays. A software approach to solve this dilemma is the production of digitally reconstructed radiographs (DRRs) which computationally simulate an X-ray-type image from CT data. The resultant image can be easily compared to an X-ray image and can provide valuable clinical information, such as small anatomical changes that have occurred between the pre-operative and operative imaging (i.e., vertebral positioning). To provide an easy way for clinicians to make their own DRRs, we propose DRR generator, a customizable extension for the open-source medical imaging application 3D Slicer. DRR generator provides rapid computation of DRRs through a highly customizable user interface. This extension provides end-users a free, open-source, and reliable way of generating DRRs. This program is integrated within 3D Slicer and thus can utilize its powerful imaging tools to provide a comprehensive segmentation and registration application for clinicians and researchers. DRR generator is available for download through 3D Slicer's in-app extension manager and requires no additional software.

The Effect of Registration on Voxel-Wise Tofts Model Parameters and Uncertainties from DCE-MRI of Early-Stage Breast Cancer Patients Using 3DSlicer

Publication: J Digit Imaging. 2020 Oct;33(5):1065-72. PMID: 32748300

Authors: Mouawad M, Biernaski H, Brackstone M, Lock M, Kornecki A, Shmuilovich O, Ben-Nachum I, Prato FS, Thompson RT, Gaede S, Gelman N.

Institution: Medical Biophysics, Western University, London, ON, Canada.

Abstract: We quantitatively investigate the influence of image registration, using open-source software (3DSlicer), on kinetic analysis (Tofts model) of dynamic contrast enhanced MRI of early-stage breast cancer patients. We also show that registration computation time can be reduced by reducing the percent sampling (PS) of voxels used for estimation of the cost function. DCE-MRI breast images were acquired on a 3T-PET/MRI system in 13 patients with early-stage breast cancer who were scanned in a prone radiotherapy position. Images were registered using a BSpline transformation with a 2 cm isotropic grid at 100, 20, 5, 1, and 0.5PS (BRAINSFit in 3D Slicer). Signal enhancement curves were analyzed voxel-by-voxel using the Tofts kinetic model. Comparing unregistered with registered groups, we found a significant change in the 90th percentile of the voxel-wise distribution of Ktrans. We also found a significant reduction in the following: (1) in the standard error (uncertainty) of the parameter value estimation, (2) the number of voxel fits providing unphysical values for the extracellular-extravascular volume fraction (ve > 1), and (3) goodness of fit. We found no significant differences in the median of parameter value distributions (Ktrans, ve) between unregistered and registered images. Differences between parameters and uncertainties obtained using 100PS versus 20PS were small and statistically insignificant. As such, computation time can be reduced by a factor of 2, on average, by using 20PS while not affecting the kinetic fit. The methods outlined here are important for studies including a large number of post-contrast images or number of patient images.

3D Slicer Craniomaxillofacial Modules Support Patient-Specific Decision-Making for Personalized Healthcare in Dental Research

Publication: Multimodal Learn Clin Decis Support Clin Image Based Proc (2020). 2020 Oct;12445:44-53. PMID: 33415323 | PDF

Authors: Bianchi J, Paniagua B, De Oliveira Ruellas AC, Fillion-Robin JC, Prietro JC, Gonçalves JR, Hoctor J, Yatabe M, Styner M, Li T, Gurgel ML, Chaves CM, Massaro C, Garib DG, Vilanova L, Castanha Henriques JF, Aliaga-Del Castillo A, Janson G, Iwasaki LR, Nickel JC, Evangelista K, Cevidanes L.

Institution: University of Michigan, 1011 North University Ave, Ann Arbor, USA.

Abstract: The biggest challenge to improve the diagnosis and therapies of Craniomaxillofacial conditions is to translate algorithms and software developments towards the creation of holistic patient models. A complete picture of the individual patient for treatment planning and personalized healthcare requires a compilation of clinician-friendly algorithms to provide minimally invasive diagnostic techniques with multimodal image integration and analysis. We describe here the implementation of the open-source Craniomaxillofacial module of the 3D Slicer software, as well as its clinical applications. This paper proposes data management approaches for multisource data extraction, registration, visualization, and quantification. These applications integrate medical images with clinical and biological data analytics, user studies, and other heterogeneous data.

Funding: R01 DE024450/DE/NIDCR NIH HHS/United States

GeodesicSlicer: a Slicer Toolbox for Targeting Brain Stimulation

Publication: Neuroinformatics. 2020 Oct;18(4):509-516. PMID: 32125609

Authors: Briend F, Leroux E, Nathou C, Delcroix N, Dollfus S, Etard O.

Institution: Normandie University, Caen, France.

Abstract: NonInvasive Brain Stimulation (NIBS) is a potential therapeutic tool with growing interest, but neuronavigation-guided software and tools available for the target determination are mostly either expensive or closed proprietary applications. To address these limitations, we propose GeodesicSlicer, a customizable, free, and open-source NIBS therapy research toolkit. GeodesicSlicer is implemented as an extension for the widely used 3D Slicer medical image visualization and analysis application platform. GeodesicSlicer uses cortical stimulation target from either functional or anatomical images to provide functionality specifically designed for NIBS therapy research. The provided algorithms are tested and they are accessible through a convenient graphical user interface. Modules have been created for NIBS target determination according to the position of the electrodes in the 10-20 system electroencephalogram and calculating correction factors to adjust the repetitive Transcranial Magnetic Stimulation (rTMS) dose for the treatment. Two illustrative examples are processing with the module. This new open-source software has been developed for NIBS therapy: GeodesicSlicer is an alternative for laboratories that do not have access to neuronavigation system. The triangulation-based MRI-guided method presented here provides a reproducible and inexpensive way to position the TMS coil that may be used without the use of a neuronavigation system.

Size of Pelvic Bone Metastasis as a Significant Prognostic Factor for Metastatic Prostate Cancer Patients

Publication: Jpn J Radiol. 2020 Oct;38(10):993-6. PMID: 32537698

Authors: Hayakawa T, Tabata KI, Tsumura H, Kawakami S, Katakura T, Hashimoto M, Watanabe Y, Iwamura M, Hasegawa T, Ishiyama H.

Institution: Department of Radiation Oncology, Kitasato University School of Medicine, Sagamihara, Japan.

Abstract: Data from 69 patients with both bone scintigraphy and pelvic CT images were selected for this analysis. Open source software (3D Slicer v.4.8.1.) was used for image analysis. Metastatic pelvic bone lesions were manually contoured, and radiomic features were extracted. As risk factors for overall survival (OS) and cause-specific survival (CSS), 105 radiomic features and clinical risk factors including age, initial prostate-specific antigen, Gleason score, TNM stage, lactate dehydrogenase (LDH), hemoglobin (Hb), alkaline phosphatase, extent of disease, visceral metastases, and radiotherapy were assessed by uni- and multivariate analyses.

Digital Endocasting in Comparative Canine Brain Morphology

Publication: Front Vet Sci. 2020 Oct 6;7:565315. PMID: 33134351 | PDF

Authors: Czeibert K, Sommese A, Petneházy Ö, Csörgő T, Kubinyi E.

Institution: Department of Ethology, Institute of Biology, ELTE Eötvös Loránd University, Budapest, Hungary.

Abstract: Computed tomography (CT) is one of the most useful techniques for digitizing bone structures and making endocranial models from the neurocranium. The resulting digital endocasts reflect the morphology of the brain and the associated structures. Our first aim was to document the methodology behind creating detailed digital endocasts of canine skulls. We created digital endocasts of the skulls of 24 different dog breeds and 4 wild canids for visualization and teaching purposes. We used CT scanning with 0.323 mm × 0.322 mm × 0.6 mm resolution. The imaging data were segmented with 3D Slicer software and refined with Autodesk Meshmixer. Images were visualized in 3D Slicer and surface models were converted to 3D PDFs to provide easier interactive access, and 3D prints were also generated for visualization purposes. Our second aim was to analyze how skull length and width relate to the surface areas of the prepiriform rhinencephalic, prefrontal, and non-prefrontal cerebral convexity areas of the endocasts. The rhinencephalic area ratio decreased with a larger skull index. Our results open the possibility to analyze the relationship between the skull and brain morphology, and to link certain features to behavior, and cognition in dogs.

A Novel Open-Source Software-Based High-Precision Workflow for Target Definition in Cardiac Radioablation

Publication: J Cardiovasc Electrophysiol. 2020 Oct;31(10):2689-95. PMID: 32648343

Authors: Hohmann S, Henkenberens C, Zormpas C, Christiansen H, Bauersachs J, Duncker D, Veltmann C.

Institution: Hannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Hannover, Germany.

Abstract: Using the free open-source 3D Slicer software platform we established a workflow for high-precision target definition based on electroanatomic maps. An import plug-in for 3D Slicer has been designed that reads electroanatomic maps generated with three mapping systems in widespread clinical use. Using our proposed workflow in a real-world patient case we were able to align the map to the computed tomography (CT) with a mean distance of 3.1 mm. Thus, points defined on the map were translated into CT space with high accuracy and a radiotherapy treatment volume was defined in CT space based on these map-derived points.

A Novel Method for Observing Tumor Margin in Hepatoblastoma Based on Microstructure 3D Reconstruction

Publication: Fetal Pediatr Pathol. 2020 Sep 24:1-10. PMID: 32969743

Authors: Liu J, Wu X, Xu C, Ma M, Zhao J, Li M, Yu Q, Hao X, Wang G, Wei B, Xia N, Dong Q.

Institution: Department of Pediatric Surgery, Affiliated Hospital of Qingdao University, Qingdao University, China.

Abstract: We investigated three-dimensional (3 D) reconstruction for the assessment of the tumor margin microstructure of hepatoblastoma (HB). Methods: Eleven surgical resections of childhood hepatoblastomas obtained between September 2018 and December 2019 were formalin-fixed, paraffin-embedded, serially sectioned at 4 μm, stained with hematoxylin and eosin (every 19th and 20th section stained with alpha-fetoprotein and glypican 3), and the digital images of all sections were acquired at 100× followed by image registration using the B-spline based method with modified residual complexity. Reconstruction was performed using 3D Slicer software. Results: The reconstructed orthogonal 3 D images clearly presented the internal microstructure of the tumor margin. The rendered 3 D image could be rotated at any angle. Conclusions: Microstructure 3 D reconstruction is feasible for observing the pathological structure of the HB tumor margin.

Setting Up 3D Printing Services for Orthopaedic Applications: A Step-by-Step Guide and an Overview of 3DBioSphere

Publication: Indian J Orthop. 2020 Sep 15;54(Suppl 2):217-27. PMID: 33194095

Authors: Shah D, Naik L, Paunipagar B, Rasalkar D, Chaudhary K, Bagaria V.

Institution: Department of Orthopaedics, Sir HN Reliance Foundation Hospital, Mumbai, India.

Abstract: Introduction: 3D printing has widespread applications in orthopaedics including creating biomodels, patient-specific instruments, implants, and developing bioprints. 3DGraphy or printing 3D models enable the surgeon to understand, plan, and simulate different procedures on it. Despite widespread applications in non-healthcare specialties, it has failed to gain traction in healthcare settings. This is perhaps due to perceived capital expenditure cost and the lack of knowledge and skill required to execute the process.

Purpose: This article is written with an aim to provide step-by-step instructions for setting up a cost-efficient 3D printing laboratory in an institution or standalone radiology centre. The article with the help of video modules will explain the key process of segmentation, especially the technique of edge detection and thresholding which are the heart of 3D printing.

Conclusion: This is likely to enable the practising orthopaedician and radiologist to set up a 3D printing unit in their departments or even standalone radiology centres at minimal startup costs. This will enable maximal utilisation of this technology that is likely to bring about a paradigm shift in planning, simulation, and execution of complex surgeries.

Keywords: 3D materials; 3D model; 3D printers; 3D printing; 3D Slicer; 3DGraphy; Patient-specific instruments; STL; Segmentation; Thresholding.

SlicerArduino: A Bridge between Medical Imaging Platform and Microcontroller

Publication: Bioengineering (Basel). 2020 Sep 11;7(3):109. PMID: 32932840 | PDF

Authors: Zaffino P, Merola A, Leuzzi D, Sabatino V, Cosentino C, Spadea MF.

Institution: Department of Clinical and Experimental Medicine, University "Magna Graecia" of Catanzaro, Catanzaro, Italy.

Abstract: Interaction between medical image platform and external environment is a desirable feature in several clinical, research, and educational scenarios. In this work, the integration between 3D Slicer package and Arduino board is introduced, enabling a simple and useful communication between the two software/hardware platforms. The open source extension, programmed in Python language, manages the connection process and offers a communication layer accessible from any point of the medical image suite infrastructure. Deep integration with 3D Slicer code environment is provided and a basic input-output mechanism accessible via GUI is also made available. To test the proposed extension, two exemplary use cases were implemented: (1) INPUT data to 3D Slicer, to navigate on basis of data detected by a distance sensor connected to the board, and (2) OUTPUT data from 3D Slicer, to control a servomotor on the basis of data computed through image process procedures. Both goals were achieved and quasi-real-time control was obtained without any lag or freeze, thus boosting the integration between 3D Slicer and Arduino. This integration can be easily obtained through the execution of few lines of Python code. In conclusion, SlicerArduino proved to be suitable for fast prototyping, basic input-output interaction, and educational purposes. The extension is not intended for mission-critical clinical tasks.

Quantification of Nasal Septal Deviation With Computed Tomography Data

Publication: J Craniofac Surg. 2020 Sep;31(6):1659-1663. PMID: 32502103

Authors: Denour E, Roussel LO, Woo AS, Boyajian M, Crozier J.

Institution: Department of Molecular Pharmacology, Physiology, and Biotechnology, Brown University, Providence, RI, USA.

Abstract: A retrospective study was conducted at a large academic center. One hundred four patients who underwent CT scans of the face were selected from a computer imaging database. Demographic variables were screened to ensure an equal number of men and women in different age groups. Digital Imaging and Communications in Medicine files were imported for 3D nasal cavity segmentation using 3D Slicer software. A volumetric analysis was performed to determine 3D NSD ratios. These values were compared to previously reported methods of obtaining objective 2D NSD measures using OsiriX and MATLAB software. Maximum deviation values were calculated using OsiriX, while the root mean square values were retrieved using MATLAB. Deviation area and curve to line ratios were both quantified using OsiriX and MATLAB.

Individual Dose Planning in Radiosynoviorthesis Treatment: Step by Step

Publication: Appl Radiat Isot. 2020 Sep;163:109177. PMID: 32392162

Authors: Torres Berdeguez MB, Thomas S, Oliveira SM, Vasconcellos de Sá L, Lopes de Souza SA, Milián FM, Xavier da Silva A.

Institution: Department of Nuclear Engineering, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil.

Abstract: Radiosynoviorthesis (RSO) is a minimally invasive treatment aiming for the necrosis of the pannus tissue by the use of radionuclide. The method suggested here starts with the segmentation of the joint effusion, synovial thickness, and area of the synovial membrane using the 3D Slicer software. The last step is the estimated value of the activity to be injected without considering the leakage of the radiopharmaceutical into the articular cavity. It includes the S-values obtained by Monte Carlo simulation coupled with the calculated therapeutic distance (ST90).

A Patient-Specific Numerical Model of the Ankle Joint for the Analysis of Contact Pressure Distribution

Publication: Proc Inst Mech Eng H. 2020 Sep;234(9):909-20. PMID: 32580651

Authors: Muralidharan L, Cardiff P, Fitzgerald K, Flavin R, Ivanković A.

Institution: School of Mechanical and Materials Engineering, University College Dublin, Dublin, Ireland.

Abstract: A patient-specific numerical model of the ankle joint has been developed using open-source software with realistic material properties that mimics the physiological movement of the foot during the stance phase of the gait cycle. The patient-specific ankle geometry has been segmented as a castellated surface using 3D Slicer from the computed tomography image scans of a subject with no congenital or acquired pathology; subsequently, the bones are smoothed, and cartilage is included as a uniform thickness extruded layer. A high-resolution Cartesian mesh has been generated using cfMesh. The material properties are assigned in the model based on the CT image Hounsfield intensities and compared to a sandwich-based material model. Gait data of the same subject was obtained and used to relatively position the tibia, talus, and calcaneus bones in the model. The stance phase of the gait cycle is simulated using a cell-centred finite-volume method implemented in open-source software OpenFOAM. The predicted peak contact pressures occur in the range of 4.85-5.53 MPa with average pressures in the range of 1.56-1.95 MPa, and the contact area ranges between 429 and 707.8 mm2 for the entire stance phase with the mid-stance phase predicting the maximum contact area. These predictions are in agreement with results from the literature. The effect of arthritis on the contact characteristics of the ankle joint has also been examined. A concentrated increase in pressure was predicted that could be manifested as pain, thereby leading to reduced motion in the ankle. The model, with continued development, has the capability to understand the effect of joint degradation and furthermore, could help provide a tool to predict the efficiency of therapeutic surgical procedures as well as guide the development of next generation ankle prostheses. The work would be made available in the University College Dublin depository (https://github.com/laxmimurali/anklejoint) as well as research gate once the article has been published.

FSRT vs. SRS in Brain Metastases-Differences in Local Control and Radiation Necrosis-A Volumetric Study

Publication: Front Oncol. 2020 Sep 30;10:559193. PMID: 33102223 | PDF

Authors: Putz F, Weissmann T, Oft D, Schmidt MA, Roesch J, Siavooshhaghighi H, Filimonova I, Schmitter C, Mengling V, Bert C, Frey B, Lettmaier S, Distel LV, Semrau S, Fietkau R.

Institution: Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.

Abstract: Segmentation was performed using the open-source software 3D Slicer (v.4.5.0). 3D Slicer is supported by the National Institutes of Health (NIH) (20) and offers different modules for segmentation, volume statistics and image coregistration. A custom-developed module was used that utilizes the built-in modules but accelerates the segmentation process by automating steps that do not require user interaction.


CroSSED Sequence, a New Tool for 3D Processing in Geosciences Using the Free Software 3DSlicer

Publication: Sci Data. 2020 Aug 14;7(1):270. PMID: 32796857 | PDF

Authors: Dorador J, Rodríguez-Tovar FJ.

Institution: Department of Earth Sciences, Royal Holloway University of London, Egham, UK.

Abstract: The scientific application of 3D imaging has evolved significantly over recent years. These techniques make it possible to study internal features by non-destructive analysis. Despite its potential, the development of 3D imaging in the Geosciences is behind other fields due to the high cost of commercial software and the scarce free alternatives. Most free software was designed for the Health Sciences, and the pre-settled workflows are not suited to geoscientific materials. Thus, an outstanding challenge in the Geosciences is to define workflows using free alternatives for Computed Tomography (CT) data processing, promoting data sharing, reproducibility, and the development of specific extensions. We present CroSSED, a processing sequence for 3D reconstructions of CT data, using 3D Slicer, a popular application in medical imaging. Its usefulness is exemplified in the study of burrows that have low-density contrast with respect to the host sediment. For geoscientists who have access to CT data and wish to reconstruct 3D structures, this method offers a wide range of possibilities and contributes to open-science and applied CT studies.

Anatomical Investigation of Middle Mesial Canals of Mandibular Molars in a Middle Eastern Population: A Cross-sectional Cone-beam Computed Tomography Study

Publication: J Contemp Dent Pract. 2020 Aug 1;21(8):910-5. PMID: 33568614

Authors: Inaty E, Jabre C, Haddad G, Nehme W, Khalil I, Naaman A, Zogheib C.

Institution: Department of Endodontics, Saint Joseph University, Faculty of Dentistry, Riad el Solh, Beirut, Lebanon.

Abstract: The presence of MMC in the mesial roots of 505 mandibular molars of 200 patients was analyzed using cone-beam computed tomography (CBCT). Then, the position of the MMC orifices with respect to the pulpal floor and the main canals orifices, and the width of dentin along the canal toward the furcation were determined using 3D Slicer v.4.10.1.

Radiomic Features of Primary Tumor by Lung Cancer Stage: Analysis in BRAF Mutated Non-Small Cell Lung Cancer

Publication: Transl Lung Cancer Res. 2020 Aug;9(4):1441-51. PMID: 32953516 | PDF

Authors: Padole A, Singh R, Zhang EW, Mendoza DP, Dagogo-Jack I, Kalra MK, Digumarthy SR.

Institution: Division of Thoracic Imaging, Massachusetts General Hospital, Boston, MA, USA.

Abstract: Our IRB approved study included 62 patients with BRAF mutations (V600 in 27 and non-V600 in 35 patients), who underwent contrast-enhanced chest CT. Tumor stage was determined based on the 8th edition of TNM staging. Two thoracic radiologists assessed the primary tumor imaging features such, including tumor size (maximum and minimum dimensions) and density (Hounsfield units, HU). De-identified transverse CT images (DICOM) were processed with 3D Slicer v.4.7 for manual lesion segmentation and estimation of radiomic features. Descriptive statistics, multivariate logistic regression, and receiver operating characteristics (ROC) were performed.

New Classification of Cochlear Hypoplasia Type Malformation: Relevance in Cochlear Implantation

Publication: J Int Adv Otol. 2020 Aug;16(2):153-7. PMID: 32784151 | PDF

Authors: Halawani RT, Dhanasingh A.

Institution: Ohud General Hospital, Ministry of Health, AL Medina, Kingdom of Saudi Arabia.

Abstract: Preoperative computed-tomography (CT) scans of cochlear implant (CI) candidates (N=31) from various clinics across the world with CH type malformation were taken for analysis. CT dataset were loaded into 3D Slicer freeware for three-dimensional (3D) segmentation of the inner-ear by capturing complete inner-ear structures from the entire dataset. Cochlear size in terms of diameter of available cochlear basal turn and length of cochlear lumen was measured from the dataset. In addition, structural connection between IAC and cochlear portions was scrutinized, which is highly relevant to the proposed CH classification in this study.

Assessment of the Severity of Coronavirus Disease: Quantitative Computed Tomography Parameters versus Semiquantitative Visual Score

Publication: Korean J Radiol. 2020 Aug;21(8):998-1006. PMID: 32677384 | PDF

Authors: Yin X, Min X, Nan Y, Feng Z, Li B, Cai W, Xi X, Wang L.

Institution: Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.

Abstract: We retrospectively enrolled 187 patients with COVID-19 treated at Tongji Hospital of Tongji Medical College from February 15, 2020, to February 29, 2020. Demographic data, imaging characteristics, and clinical data were collected, and based on the clinical classification of severity, patients were divided into groups 1 (mild) and 2 (severe/critical). A semiquantitative visual score was used to estimate the lesion extent. 3D Slicer was used to precisely quantify the volume and CT value of the lung and lesions. Correlation coefficients of the quantitative CT parameters, semiquantitative visual score, and clinical classification were calculated using Spearman's correlation. A receiver operating characteristic curve was used to compare the accuracies of quantitative and semi-quantitative methods.

Cost-Effective Method for 3-Dimensional Printing Dynamic Multiobject and Patient-Specific Brain Tumor Models: Technical Note

Publication: World Neurosurg. 2020 Aug;140:173-9. PMID: 32360916

Authors: Damon A, Clifton W, Valero-Moreno F, Quinones-Hinojosa A.

Institution: Department of Neurological Surgery, Mayo Clinic Florida, Jacksonville, FL, USA.

Abstract: Three-dimensional (3D) printing is a powerful tool for replicating patient-specific anatomic features for education and surgical planning. The advent of "desktop" 3D printing has created a cost-effective and widely available means for institutions with limited resources to implement a 3D-printing workflow into their clinical applications. The ability to physically manipulate the desired components of a "dynamic" 3D-printed model provides an additional dimension of anatomic understanding. There is currently a gap in the literature describing a cost-effective and time-efficient means of creating dynamic brain tumor 3D-printed models.

Methods: Using free, open-access software, 3D Slicer for patient imaging to Standard Tessellation Language file conversion, as well as open access Standard Tessellation Language editing software (Meshmixer), both intraaxial and extraaxial brain tumor models of patient-specific pathology are created.

Accuracy of Implant Placement Position Using Nondental Open-Source Software: An In Vitro Study

Publication: J Prosthodont. 2020 Aug;29(7):604-610. PMID: 32495453 | PDF

Authors: Talmazov G, Bencharit S, Waldrop TC, Ammoun R.

Institution: Department of General Practice, School of Dentistry, Virginia Commonwealth University, Richmond, VA, USA.

Abstract: A set of Digital Imaging and Communications in Medicine (DICOM) files from a cone beam computed tomography of a patient missing maxillary right first premolar was used. Implant planning was done using two open-source programs: A nondental 3D Slicer/Blender (3DSB) software and a commercial dental implant treatment planning program: Blue Sky Plan 4 (BSP4). An intraoral scan of the same patient was used to create a standard tessellation language (STL) file of the maxillary arch and later printed into 20 identical casts. Ten surgical guides were printed for each group as well. A dental implant (3.8 mm × 12 mm, Biohorizons) was placed into each cast using fully guided surgical protocol. The horizontal displacements at the implant cervical platform and at the implant apex as well as the angulation displacements were measured using digital scanning of the implant scan bodies and were analyzed using a 3D compare software. Statistical analyses were conducted (⍺ = 0.05) using t-test and F-test to examine differences in trueness and precision, respectively.

Timing of Ossification of the Anterior Skull Base in Syndromic Synostosis

Publication: J Craniofac Surg. 2020 Jul-Aug;31(5):1256-1260. PMID: 32282683

Authors: Nassar AH, Mercan E, Massenburg BB, Lee A, Brown J, Skladman R, Guo Y, Hopper RA.

Institution: Department of Neurological Surgery, University of Washington, Seattle, WA, USA.

Abstract: The anterior skull base undergoes a progressive ossification after birth. This has implications on the epidural dissection of early trans-craniofacial osteotomy procedures such as monobloc advancements. Our purpose was to determine the rate of ossification in syndromic synostosis patients relative to a normal cohort to establish when maturation of the anterior skull base is complete. The authors analyzed CT scans from 35 patients with Crouzon, Apert or Pfeiffer syndrome, and 84 patients without any craniofacial anomaly between the ages of 0 and 6 years. The non-ossified anterior skull base area was measured using 3D Slicer. The authors compared the sizes of the defects at different ages between the three syndromes and with the control group using Mann-Whitney test. Significance was set at P < 0.05. All patients less than 12 months of age had a measurable defect anterior to the cribriform whereas patients greater than five years of age had full ossification of the anterior skull base with no evidence of defect. The relationship of defect size and age at scan was non-linear, with most defects closing rapidly in the first six months. The temporal closure pattern of the defect was similar between the three syndromes and the control group with no significant difference. Our findings indicate that syndromic children undergo skull base maturation at the same rate as non-syndromic cases, with the majority ossified by three years of age. Anterior skull base surgeries performed before three years should optimize visualization of this area during dissection.

Long-Term Stability of Vascularized Adipofascial Flaps in Facial Reconstruction

Publication: Facial Plast Surg Aesthet Med. 2020 Jul/Aug;22(4):262-7. PMID: 32250652

Authors: Strohl MP, Junn JC, House AE, Heaton CM, Seth R, Park AM, Knott PD.

Institution: Division of Neuroradiology, Department of Radiology, University of California, San Francisco, San Francisco, CA, USA.

Abstract: Objectives: To determine the quantitative volume change over time of vascularized adipofascial anterolateral thigh (AFALT) free flaps in facial reconstruction, and to evaluate patient factors that are associated with changes in volume. Methods: A retrospective review was performed on patients who underwent AFALT reconstruction for large volume parotid and midface defects after head and neck cancer surgery at a single tertiary care hospital from 2011 to 2018. Flap volume was measured at different time points using 3D Slicer, a free open source software for medical image computing. Trends in volume change over time were evaluated. A multiple linear regression model was used to analyze patient factors associated with mean final volume change. Results: Twenty-one patients were included. The median follow-up period from surgery was 17 months (interquartile range [IQR] = 9-25 months). The first imaging study was obtained a median of 3 months after surgery (IQR = 1-4 months). The majority of patients underwent postoperative radiation (20/21, 95%). Mean final total volume percentage change over time was 96.6% (standard deviation = 21.7%). After controlling for age, smoking history, recurrence, and length of follow-up, a reduction in body mass index (BMI) ≥1.5 U from baseline had the greatest association with mean final volume percentage change (β -31, 95% confidence interval: -52 to -11, p = 0.005). Conclusions: Free tissue transfer using AFALT flaps in the head and neck provided relatively stable volume maintenance over time, even after postoperative radiation. The volume of transplanted fat can change depending on patient factors, such as BMI.

Three-Dimensional Volumetric Changes in Posterior Vault Distraction With Distraction Osteogenesis

Publication: J Craniofac Surg. 2020 Jul-Aug;31(5):1301-6. PMID: 32282486

Authors: Thatikunta M, Pearson L, Nguyen C, John K, Abolfotoh M, Mutchnick I, Gump W, Chariker M, Moriarty T, Rapp SJ.


Institution: Pediatric Plastic Surgery, Norton Children's Hospital, Louisville, KY.

Abstract: From 2007 to 2019, a single institution retrospective review revealed 232 craniosynostosis patients. Fourteen demonstrated lambdoid synostosis (6%), and of those, 11 patients were included in the study due to treatment with PVDO or representative sample. Six patients had unilateral synostosis and 5 had bilateral synostosis. Imaging protocol for PVDO patients included preoperative head CT within 1 month of surgery and 8 weeks following distraction cessation with weekly skull plain films. 3D volumetric analyses were performed on pre and postoperative head CT using 3D Slicer software.

Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandibular Condyle. A Comparative Study Using a Surface-to-Surface Matching Technique

Publication: Int J Environ Res Public Health. 2020 Jul 3;17(13):4789. PMID: 32635238 | PDF

Authors: Lo Giudice A, Quinzi V, Ronsivalle V, Farronato M, Nicotra C, Indelicato F, Isola G.

Institution: Department of General Surgery and Surgical-Medical Specialties, Section of Orthodontics, School of Dentistry, University of Catania, Catania, Italy.

Abstract: The aim of this study was to assess the accuracy of 3D rendering of the mandibular condylar region obtained from different semi-automatic segmentation methodology. A total of 10 Cone beam computed tomography (CBCT) were selected to perform semi-automatic segmentation of the condyles by using three free-source software (Invesalius, version 3.0.0, Centro de Tecnologia da Informação Renato Archer, Campinas, SP, Brazil; ITK-Snap, version2.2.0; 3D Slicer, version 4.10.2) and one commercially available software Dolphin 3D (Dolphin Imaging, version 11.0, Chatsworth, CA, USA). The same models were also manually segmented (Mimics, version 17.01, Materialise, Leuven, Belgium) and set as ground truth. The accuracy of semi-automatic segmentation was evaluated by (1) comparing the volume of each semi-automatic 3D rendered condylar model with that obtained with manual segmentation, (2) deviation analysis of each 3D rendered mandibular models with those obtained from manual segmentation. No significant differences were found in the volumetric dimensions of the condylar models among the tested software (p > 0.05). However, the color-coded map showed underestimation of the condylar models obtained with ITK-Snap and Slicer 3D, and overestimation with Dolphin 3D and Invesalius. Excellent reliability was found for both intra-observer and inter-observer readings. Despite the excellent reliability, the present findings suggest that data of condylar morphology obtained with semi-automatic segmentation should be taken with caution when an accurate definition of condylar boundaries is required.

Impact of Local Left Atrial Wall Thickness on the Incidence of Acute Pulmonary Vein Reconnection After Ablation Index-Guided Atrial Fibrillation Ablation

Publication: Int J Cardiol Heart Vasc. 2020 Jul 3;29:100574. PMID: 32642554 | PDF

Authors: Mulder MJ, Kemme MJB, Hagen AMD, Hopman LHGA, van de Ven PM, Hauer HA, Tahapary GJM, Götte MJW, van Rossum AC, Allaart CP.


Institution: Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam Cardiovascular Sciences Amsterdam, The Netherlands.

Abstract: CT image analysis was performed blinded to ablation data using open-source software, (3D Slicer. LA diameter was measured in the anteroposterior direction on axial non-reformatted images. LA wall thickness measurements were performed similarly as described previously [18], and as depicted in Fig. 1. Two separate circular regions of interest were drawn on coronal images inside the LA (blood pool) and inside the ventricular myocardium. Intensity histograms were constructed from the regions of interest to define mean and standard deviation HU for blood pool and myocardium.

Surgical Tracking, Registration, and Navigation Characterization for Image-guided Renal Interventions

Publication: Annu Int Conf IEEE Eng Med Biol Soc. 2020 Jul;2020:5081-4. PMID: 33019129 | PDF

Authors: Jackson P, Simon R, Linte C.

Institution: DCenter for Imaging Science, Rochester Institute of Technology Rochester, NY, USA.

Abstract: All image-guided navigation experiments were conducted using the 3D Slicer IGT platform [8] [9]. We conducted several experiments using both a custom-developed calibration device of known geometry, as well as a patient-specific 3D printed model of a kidney generated from a MR image. The calibration device consisted of a rectangular tile featuring 30 3-mm dia. hemispherical landmarks distributed in a non-symmetric pattern.


Can Surgeons Identify ACL Femoral Ridges Landmark and Optimal Tunnel Position? A 3D Model Study

Publication: Arthrosc Sports Med Rehabil. 2020 Jul 29;2(4):e361-e368. PMID: 32875301 | PDF

Authors: Laverdiere C, Schupbach D, Schupbach J, Harvey E, Boily M, Burman M, Martineau PA.


Institution: Department of Orthopedic Surgery, McGill University Health Centre, Montreal, Canada.

Abstract: The 3D MRI Digital Imaging and Communications in Medicine scans were imported in The 3D MRI Digital Imaging and Communications in Medicine scans were imported in 3D slicer software. This software enables segmentation of the Digital Imaging and Communications in Medicine scans to create a 3D model that mimics the native anatomy. software. This software enables segmentation of the Digital Imaging and Communications in Medicine scans to create a 3D model that mimics the native anatomy.

Potential Role of Convolutional Neural Network Based Algorithm in Patient Selection for DCIS Observation Trials Using a Mammogram Dataset

Publication: Acad Radiol. 2020 Jun;27(6):774-9. PMID: 31526687

Authors: Mutasa S, Chang P, Van Sant EP, Nemer J, Liu M, Karcich J, Patel G, Jambawalikar S, Ha R.

Institution: Department of Medical Physics and Radiology, Columbia University Medical Center, New York, NY, USA.

Abstract: An IRB-approved retrospective study was performed. 246 unique images from 123 patients were used for our CNN algorithm. In total, 164 images in 82 patients diagnosed with DCIS by stereotactic-guided biopsy of calcifications without any upgrade at the time of surgical excision (pure DCIS group). A total of 82 images in 41 patients with mammographic calcifications yielding occult invasive carcinoma as the final upgraded diagnosis on surgery (occult invasive group). Two standard mammographic magnification views (CC and ML/LM) of the calcifications were used for analysis. Calcifications were segmented using an open source software platform 3D Slicer and resized to fit a 128 × 128 pixel bounding box. A 15 hidden layer topology was used to implement the neural network. The network architecture contained five residual layers and dropout of 0.25 after each convolution. Five-fold cross validation was performed using training set (80%) and validation set (20%). Code was implemented in open source software Keras with TensorFlow on a Linux workstation with NVIDIA GTX 1070 Pascal GPU.


Free-to-Use DIR Solutions in Radiotherapy: Benchmark Against Commercial Platforms Through a Contour-Propagation Study

Publication: Phys Med. 2020 Jun;74:110-7. PMID: 32464468

Authors: Scaggion A, Fiandra C, Loi G, Vecchi C, Fusella M.

Institution: Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Italy.

Abstract: ElastiX, BRAINS and Plastimach, available as modules in the open source platform 3D Slicer, were tested as the recent AAPM Task group 132 guidelines proposes. The overlap of the DIR-mapped ROIs in four computational anthropomorphic phantoms was measured. To avoid bias every algorithm was left to run without any human interaction nor particular registration strategy. The accuracy of the algorithms was measured using the Dice Similarity Coefficient (DSC) and Mean Distance to Conformity (MDC) metrics. The registration quality was compared to the recommended geometrical accuracy suggested by AAPM TG132 and to the results of a large population-based study performed with commercial DIR solutions.

Combining Stereoscopic Video and Virtual Reality Simulation to Maximize Education in Lateral Skull Base Surgery

Publication: Otolaryngol Head Neck Surg. 2020 Jun;162(6):922-5. PMID: 32180502

Authors: Barber SR, Jain S, Mooney MA, Almefty KK, Lawton MT, Son YJ, Stevens SM.

Institution: Department of Otolaryngology-Head and Neck Surgery, University of Arizona College of Medicine, Tucson, AZ, USA.

Abstract: Mastery of lateral skull base (LSB) surgery requires thorough knowledge of complex, 3-dimensional (3D) microanatomy and techniques. While supervised operation under binocular microscopy remains the training gold standard, concerns over operative time and patient safety often limit novice surgeons' stereoscopic exposure. Furthermore, most alternative educational resources cannot meet this need. Here we present proof of concept for a tool that combines 3D-operative video with an interactive, stereotactic teaching environment. Stereoscopic video was recorded with a microscope during translabyrinthine approaches for vestibular schwannoma. Digital imaging and communications in medicine (DICOM) temporal bone computed tomography images were segmented using 3D Slicer. Files were rendered using a game engine software built for desktop virtual reality. The resulting simulation was an interactive immersion combining a 3D operative perspective from the lead surgeon's chair with virtual reality temporal bone models capable of hands-on manipulation, label toggling, and transparency modification. This novel tool may alter LSB training paradigms.

Is Full Endoscopic Lumbar Discectomy Less Invasive Than Conventional Surgery? A Randomized MRI Study

Publication: World Neurosurg. 2020 Jun;138:e867-e875. PMID: 32251813

Authors:Tacconi L, Signorelli F, Giordan E.

Institution: Neurosurgical Department, Azienda Sanitaria Universitaria Integrata di Trieste, Trieste, Italy.

Abstract: We prospectively collected the data from 50 patients with a single-level lumbar foraminal herniation, invalidating radicular pain, and adequate imaging studies available (postoperative magnetic resonance imaging [MRI] <24 hours). These patients had been randomly assigned to FELD (n = 25) or OD (n = 25). Data were collected on age, sex, leg and back pain, complications, and follow-up time. Muscle segmentations were performed manually using 3D Slicer software on postoperative isovolumetric T1-weighted contrast-enhanced and T2-weighted short tau inversion recovery MRI scans. Both sequences were processed using multiplanar reconstruction in orthogonal planes. The clinical and demographic characteristics and volumetric data were then compared between the 2 groups.

One Step Before 3D Printing-Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandible: A Comparative Study Using a Surface-to-Surface Matching Technique

Publication: Materials (Basel). 2020 Jun 21;13(12):2798. PMID: 32575875 | PDF

Authors: Lo Giudice A, Ronsivalle V, Grippaudo C, Lucchese A, Muraglie S, Lagravère MO, Isola G.

Institution: Department of Orthodontics, University of Sacred Heart of Rome, Rome, Italy.

Abstract: The accuracy of 3D reconstructions of the craniomaxillofacial region using cone beam computed tomography (CBCT) is important for the morphological evaluation of specific anatomical structures. Moreover, an accurate segmentation process is fundamental for the physical reconstruction of the anatomy (3D printing) when a preliminary simulation of the therapy is required. In this regard, the objective of this study is to evaluate the accuracy of four different types of software for the semiautomatic segmentation of the mandibular jaw compared to manual segmentation, used as a gold standard. Twenty cone beam computed tomography (CBCT) with a manual approach (Mimics) and a semi-automatic approach (Invesalius, ITK-Snap, Dolphin 3D, 3D Slicer) were selected for the segmentation of the mandible in the present study. The accuracy of semi-automatic segmentation was evaluated: (1) by comparing the mandibular volumes obtained with semi-automatic 3D rendering and manual segmentation and (2) by deviation analysis between the two mandibular models. An analysis of variance (ANOVA) was used to evaluate differences in mandibular volumetric recordings and for a deviation analysis among the different software types used. Linear regression was also performed between manual and semi-automatic methods. No significant differences were found in the total volumes among the obtained 3D mandibular models (Mimics = 40.85 cm3, ITK-Snap = 40.81 cm3, Invesalius = 40.04 cm3, Dolphin 3D = 42.03 cm3, Slicer 3D = 40.58 cm3). High correlations were found between the semi-automatic segmentation and manual segmentation approach, with R coefficients ranging from 0,960 to 0,992. According to the deviation analysis, the mandibular models obtained with ITK-Snap showed the highest matching percentage (Tolerance A = 88.44%, Tolerance B = 97.30%), while those obtained with Dolphin 3D showed the lowest matching percentage (Tolerance A = 60.01%, Tolerance B = 87.76%) (p < 0.05). Colour-coded maps showed that the area of greatest mismatch between semi-automatic and manual segmentation was the condylar region and the region proximate to the dental roots. Despite the fact that the semi-automatic segmentation of the mandible showed, in general, high reliability and high correlation with the manual segmentation, caution should be taken when evaluating the morphological and dimensional characteristics of the condyles either on CBCT-derived digital models or physical models (3D printing).

Pre-Clinical Evaluation of an Image-Guided In-Situ Raman Spectroscopy Navigation System for Targeted Prostate Cancer Interventions

Publication: Int J Comput Assist Radiol Surg. 2020 May;15(5):867-76. PMID: 32227280

Authors: Shams R, Picot F, Grajales D, Sheehy G, Dallaire F, Birlea M, Saad F, Trudel D, Menard C, Leblond F, Kadoury S.

Institution: Centre Hospitalier de l'Universite de Montreal Research Center, Montreal, Canada.

Abstract: The proposed system developed in 3D Slicer includes an electromagnetically tracked Raman spectroscopy probe, along with tracked TRUS imaging automatically registered to diagnostic MRI. The proposed system is tested on both custom gelatin tissue-simulating optical phantoms and biological tissue phantoms. A random-forest classifier was then trained on optical spectrums from ex-vivo prostates following prostatectomy using our optical probe. Preliminary in-human results are presented with the Raman spectroscopy instrument to detect malignant tissue in-situ with histopathology confirmation.

The Impact of Intracortical Lesions on Volumes of Subcortical Structures in Multiple Sclerosis.

Publication: AJNR Am J Neuroradiol. 2020 May;41(5):804-8. PMID: 32381540 | PDF

Authors: Kalinin I, Makshakov G, Evdoshenko E.

Institution: From the SPb Center of Multiple Sclerosis and AID (SBIH City Clinical Hospital No. 31), St. Petersburg, Russia.

Abstract: Seventy-one patients with MS were included. The volumes of intracortical lesions and white matter lesions were identified on double inversion recovery and FLAIR, respectively, by using 3D Slicer. Volumes of white matter T1 hypointensities and subcortical gray matter, thalamus, caudate, putamen, and pallidum volumes were calculated using FreeSurfer. Age, MS duration, and the Expanded Disability Status Scale score were assessed.

Unilateral Maxillary Central Incisor Root Resorption After Orthodontic Treatment for Angle Class II, Division 1 Malocclusion With Significant Maxillary Midline Deviation: A Possible Correlation With Root Proximity to the Incisive Canal

Publication: Korean J Orthod. 2020 May 25; 50(3):216–26. PMID: 32475849 | PDF

Authors: Imamura T, Uesugi S, Ono T.


Institution: Department of Orthodontic Science, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan.

Abstract: The CBCT images acquired before and after active treatment were superimposed according to methods reported in a previous study. In addition, using Mimics software (version 18.0; Materialise, Leuven, Belgium) and 3D Slicer v.4.7.0, we confirmed the 3D configuration, amount of tooth displacement before and after treatment, and amount of root resorption by extracting and creating models of the maxillary central incisors (1,200–5,000 Hounsfield unit [HU]), incisive canal (−800 to 400 HU), and cortical bone around the incisive canal (660–2,000 HU. The periodontal ligament and root apex were relatively clear, and segregation of the root and alveolar bone could be easily performed.

Assisting Vascular Surgery with Smartphone Augmented Reality

Publication: Cureus. 2020 May 8;12(5):e8020. PMID: 32528759 | PDF

Authors: Aly O.


Institution: General Surgery, Queen Alexandra Hospital, Portsmouth, UK.

Abstract: The workflow for preoperative planning utilizes cross-sectional imaging in the form of computed tomography angiogram (CTA) Digital Imaging and Communications in Medicine (DICOM®) images (National Electrical Manufacturers Association, Rosslyn, VA). These images were loaded into the 3D Slicer (a free open-source software application for medical image computing) to allow examination and annotation of the patient’s anatomy. Important landmarks and structures, such as the inguinal ligament and common femoral vein, were annotated using the 3D Slicer software. Tracking markers were placed on the skin to highlight optimal skin incisions that were tailored to the patient.

Accuracy of the Freehand (Fennell) Technique Using a Uniform Entry Point and Sagittal Trajectory for Insertion of Thoracic Pedicle Screws: A Computed Tomography-Based Virtual Simulation Study

Publication: Neurol India. 2020 Mar-Apr;68(2):468-71. PMID: 32415026

Authors: Swaminathan G, Muralidharan V, Devakumar D, Joseph BV.

Institution: Department of Neurological Sciences, Christian Medical College, Vellore, Tamil Nadu, India.

Abstract: Normal CT thoracic spine obtained from CT thorax data of five patients were used in the 3D Slicer environment using PSS for simulation. Entry points and axial trajectory as described by Fennell et al. and a sagittal trajectory parallel to the superior endplate were used for simulating the freehand technique using EA (entry angle) mode in the PSS. An ideal trajectory through the midsection of the pedicle from the same entry point and a sagittal trajectory parallel to the superior endplate were simulated using the ET (Entry Target) mode. Angle predicted by the software for an ideal axial trajectory was compared with the Fennell technique and this angle difference was noted at all the levels. Presence of pedicle breach was noted while simulating the Fennell technique.

New, Simple and Reliable Volumetric Calculation Technique in Incisional Hernias With Loss of Domain

Publication: Hernia. 2020 Apr;24(2):403-9. PMID: 31218439

Authors: Martre P, Sarsam M, Tuech JJ, Coget J, Schwarz L, Khalil H.

Institution: Department of Digestive Surgery, Rouen University Hospital, 1 rue de Germont, 76000, Rouen, France.

Abstract: The management of hernias with loss of domain is a challenging problem. It has been shown that the volume of the incisional hernia/peritoneal volume ratio < 20% was a predictive factor for tension-free fascia closure, after pre-operative pneumoperitoneum preparation (Goni Moreno technique). In this study, we propose an easy, reliable and fast technique to perform volumetric calculation, by the surgeon alone.

Materials and methods: 3D Slicer software (free open-source software) was used to calculate with precision the intra-peritoneal and intra-hernia volumes, and to create a 3D reconstruction of both volumes. The measurement technique is described step by step using detailed figures and videos.

Computed Tomographic Portography with Esophageal Variceal Measurements in the Evaluation of Esophageal Variceal Severity and Assessment of Esophageal Variceal Volume Efficacy

Publication: Acad Radiol. 2020 Apr;27(4):528-35. PMID: 31303576

Authors: Wan S, Wei Y, Yu H, Li Y, Yao S, Song B.

Institution: Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan Province, China.

Abstract: A total of 53 EV patients examined by CTP within 4 weeks of upper endoscopy were evaluated, the patients were divided into a nonconspicuous EV group (mild-to-moderate EV, n = 28) and a conspicuous EV group (severe EV, n = 25) according to endoscopy results. The diameter, cross-sectional surface area (CSA), and volume of EV were measured independently using 3D Slicer (Boston) by two experienced abdominal radiologists blinded to endoscopy findings. The averaged values measured by the two observers were used in the final dataset, these indicators' predictive performances were studied by using receiver operating characteristic curve analysis, and the area under the curve (Az) and the cutoff values were calculated to distinguish mild-to-moderate from severe EV.

The Dynamics of Hematoma Surface Regularity and Hematoma Expansion in Acute Intracerebral Hemorrhage

Publication: J Clin Neurosci. 2020 Apr;74:160-3. PMID: 32089386

Authors: Oge DD, Topcuoglu MA, Gocmen R, Arsava EM.

Institution: Department of Neurology, Faculty of Medicine, Hacettepe University, Ankara, Turkey.

Abstract: The clarification of factors that contribute to hematoma expansion in the setting of intracerebral hemorrhage (ICH) and the relevant physical dynamics are implemental for development of management strategies. Herein, we assessed the interplay between hematoma expansion and surface regularity of intracerebral bleeds. To do so, hematoma contours were outlined on admission and follow-up computed tomography (CT) studies using semi-automated thresholding algorithms in 133 ICH patients. Hematoma volume, surface area and surface regularity [SR=6√πvolumesurfacearea3, ranging from 0 (very irregular surface) to 1 (perfectly regular surface suggestive of 3D spherical structure)] were determined by 3D Slicer software . Hematoma growth was defined as ≥33% relative growth, or ≥ 6 mL absolute growth. Our results are as follows: The median (IQR) hematoma volume was 14.2 (6.0-34.9) mL on admission CT obtained 2.4 (1.5-4.4) hours after symptom onset; the mean ± SD SR value was calculated as 0.62 ± 0.14. Patients who underwent imaging at earlier time points were more likely to have higher SR (r = 0.18; p = 0.035). The median hematoma volume at follow-up, 35 (21-47) hours after the initial scan, was 19.7 (6.9-44.4) mL. The regularity index decreased significantly at this time point to 0.58 ± 0.13 (p < 0.001) and corresponding increase of surface irregularity was independent of change in hematoma volume. Baseline hematoma volume, INR, and time to initial imaging were significant predictors of hematoma expansion. In conclusion, our findings suggest that hematomas evolve into more irregular 3D shapes during follow-up. These observations are consistent with the 'domino' hypothesis put forward for ICH expansion.

The Study of Self-Constructed Brainstem Fiber Bundle by Neurosurgeon Through Using 3D-Slicer Software

Publication: Zhonghua Yi Xue Za Zhi. 2020 Mar 3;100(8):604-9. PMID: 32164115

Authors: Yang J, Wu YT, Dong K, Jiang H, Yang R, Wu Y, Xia HJ, Sun XC, Zhong D.

Institution: Department of Neurosurgery, the First Affiliated Hospital of Chongqing Medical University, Chongqing, China.

Abstract: To explore the methods and appliaction value for self-constructing brainstem fiber bundles by neurosurgeon through 3D Slicer software in neurosurgical preoperative planning. Methods: The DCIOM format imaging data of 31 patients with neurosurgical brainstem lesions were collected who admitted to Neurosurgery Department at the First Affiliated Hospital of Chongqing Medical University from June 2018 to May 2019 and imported into the 3D Slicer software system. The neurosurgery specialists independently constructed the fiber bundles to generate two-dimensional Fraction Anisotropy maps, Directionally Encoded Color maps and three-dimensional fiber bundle tracing maps. Building a preopertive virtual pathological anatomical imaging system and understanding the three-dimensional pathological anatomical relationship between lesions and brain stem fiber bundles to develop an accurate surgical approach and simulate surgicalprocedures before surgery.

Sex Estimation Using Subpubic Angle From Reconstructed Three-Dimensional Computed Tomography Pelvic Model in a Contemporary Malaysian Population

Publication: Anat Cell Biol. 2020 Mar;53(1):27-35. PMID: 32274246 | PDF

Authors: Mohd Ali SH, Omar N, Shafie MS, Nik Ismail NA, Hadi H, Nor FM.

Institution: Forensic Unit, Department of Pathology, Universiti Kebangsaan Malaysia Medical Centre, Kuala Lumpur, Malaysia.

Abstract: Research in forensic anthropology is recent in Malaysia due to limited access to documented skeletal collections. However, advanced imaging techniques provide virtual bone samples for use in morphometric studies to establish population-specific standards by virtual anthropology. This study examined sexual dimorphism in the subpubic angle using a three-dimensional computed tomography model of the pelvis, in a contemporary Malaysian population. The sample comprised multidetector computed tomography (MDCT) scans of 50 male and 50 female adults. Segmentation of the MDCT scans was performed using 3D Slicer, and four landmarks were acquired using Stratovan Checkpoint for the subpubic angle measurement. The technical error of measurement (TEM), relative TEM, and coefficient of reliability (R) exhibited high reliability in measurements. Results showed that the subpubic angle in males was 68.6°±7.6° and in females 87.4°±6.5°. The subpubic angle in females was significantly larger than in males (P<0.001). Inverse correlation was found between the subpubic angle and age, in both males (r=-0.449, P<0.01) and females (r=-0.385, P<0.01). The overall accuracy of sex estimation using the subpubic angle was 94% (P<0.001). The subpubic angle, with a demarcating point of 78.6°, showed a sensitivity and specificity of 94% in the classification of female individuals. In conclusion, sex estimation using the subpu bic angle is highly accurate, with a high degree of expected sensitivity and specificity in the Malaysian population.

Association between Maxillary Sinus Dimensions and Midface Width: 2-D and 3-D Volumetric Cone-beam Computed Tomography Cross-sectional Study

Publication: J Contemp Dent Pract. 2020 Mar 1;21(3):317-21. PMID: 32434981

Authors: Alhazmi A.

Institution: Department of Preventive Dental Science, Division of Orthodontics, Jazan University, College of Dentistry, Jazan, Kingdom of Saudi Arabia.

Abstract: A cross-sectional observational study was conducted using 54 cone-beam computed tomography scans obtained from patients starting their treatment in dental clinics of dental college, Jazan University. Maximal vertical diameter (maximal height) of the maxillary sinus (MSH), maximal horizontal diameter (maximal width) of the maxillary sinus (MSW), maximal anteroposterior diameter (maximal length) of the maxillary sinus (MSL), MAW, and maxillary sinus volume (MSV) were measured and recorded using 3D Slicer software. The Spearman's rank correlation coefficient (rho-ρ) was used to analyze the strength and type of the relationship between variables.

Three-Dimensional Cone Beam Computed Tomography Analysis of Temporomandibular Joint Response to the Twin-Block Functional Appliance

Publication: Korean J Orthod. 2020 Mar;50(2):86-97. PMID: 32257934 | PDF

Authors: Jiang YY, Sun L, Wang H, Zhao CY, Zhang WB.

Institution: Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University, Nanjing, China.

Abstract: Seventeen patients with Class II division 1 malocclusion treated using Twin-block and nine untreated patients with a similar malocclusion were included in this research. We collected their cone beam computed tomography (CBCT) data from before and 8 months after treatment. Segmentations were constructed using ITK-SNAP. Condylar volume and superficial area were measured using 3D Slicer. The 3D landmarks were identified on CBCT images by using Dolphin software to assess the condylar positional relationship. 3D models of the mandible and glenoid fossa of the patients were constructed and registered via voxel-based superimposition using 3D Slicer. Thereafter, skeletal changes could be visualized using 3DMeshMetric in any direction of the superimposition on a color-coded map. All the superimpositions were measured using the same scale on the distance color-coded map, in which red color represents overgrowth and blue color represents resorption.

Evaluation of the Heart and Lung Dosimetric Parameters in Deep Inspiration Breath Hold Using 3D Slicer

Publication: Radiat Oncol J. 2020 Mar;38(1):68-76. PMID: 32229811 | PDF

Authors: Eskandari A, Nasseri S, Gholamhosseinian H, Hosseini S, Farzaneh MJK, Keramati A, Naji M, Rostami A, Momennezhad M.

Institution: Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.

Abstract: The present study was conducted to compare dosimetric parameters for the heart and left lung between free breathing (FB) and deep inspiration breath hold (DIBH) and determine the most important potential factors associated with increasing the lung dose for left-sided breast radiotherapy using image analysis with 3D Slicer software.

Materials and methods: Computed tomography-simulation scans in FB and DIBH were obtained from 17 patients with left-sided breast cancer. After contouring, three-dimensional conformal plans were generated for them. The prescribed dose was 50 Gy to the clinical target volume. In addition to the dosimetric parameters, the irradiated volumes and both displacement magnitudes and vectors for the heart and left lung were assessed using 3D Slicer software.


Comprehensive Review of 3D Segmentation Software Tools for MRI Usable for Pelvic Surgery Planning

Publication: J Digit Imaging. 2020 Feb;33(1):99-110. PMID: 31236743 | PDF

Authors: Virzì A, Muller CO, Marret JB, Mille E, Berteloot L, Grévent D, Boddaert N, Gori P, Sarnacki S, Bloch I.

Institution: LTCI, Télécom Paris, Institut Polytechnique de Paris, Paris, France.

Abstract: Patient-specific 3D modeling is the first step towards image-guided surgery, the actual revolution in surgical care. Pediatric and adolescent patients with rare tumors and malformations should highly benefit from these latest technological innovations, allowing personalized tailored surgery. This study focused on the pelvic region, located at the crossroads of the urinary, digestive, and genital channels with important vascular and nervous structures. The aim of this study was to evaluate the performances of different software tools to obtain patient-specific 3D models, through segmentation of magnetic resonance images (MRI), the reference for pediatric pelvis examination. Twelve software tools freely available on the Internet and two commercial software tools were evaluated using T2-w MRI and diffusion-weighted MRI images. The software tools were rated according to eight criteria, evaluated by three different users: automatization degree, segmentation time, usability, 3D visualization, presence of image registration tools, tractography tools, supported OS, and potential extension (i.e., plugins). A ranking of software tools for 3D modeling of MRI medical images, according to the set of predefined criteria, was given. This ranking allowed us to elaborate guidelines for the choice of software tools for pelvic surgical planning in pediatric patients. The best-ranked software tools were Myrian Studio, ITK-SNAP, and 3D Slicer, the latter being especially appropriate if nerve fibers should be included in the 3D patient model. To conclude, this study proposed a comprehensive review of software tools for 3D modeling of the pelvis according to a set of eight criteria and delivered specific conclusions for pediatric and adolescent patients that can be directly applied to clinical practice.

Temporomandibular Joint Damage in K/BxN Arthritic Mice

Publication: Int J Oral Sci. 2020 Feb 6;12(1):5. PMID: 32024813 | PDF

Authors: Kuchler-Bopp S, Mariotte A, Strub M, Po C, De Cauwer A, Schulz G, Van Bellinghen X, Fioretti F, Clauss F, Georgel P, Benkirane-Jessel N, Bornert F.

Institution: INSERM (French National Institute of Health and Medical Research), UMR 1260, Regenerative NanoMedicine (RNM), FMTS, Strasbourg, France.

Abstract: Rheumatoid arthritis (RA) is an autoimmune disease affecting 1% of the world population and is characterized by chronic inflammation of the joints sometimes accompanied by extra-articular manifestations. K/BxN mice, originally described in 1996 as a model of polyarthritis, exhibit knee joint alterations. The aim of this study was to describe temporomandibular joint (TMJ) inflammation and damage in these mice. We used relevant imaging modalities, such as micro-magnetic resonance imaging (μMRI) and micro-computed tomography (μCT), as well as histology and immunofluorescence techniques to detect TMJ alterations in this mouse model. Histology and immunofluorescence for Col-I, Col-II, and aggrecan showed cartilage damage in the TMJ of K/BxN animals, which was also evidenced by μCT but was less pronounced than that seen in the knee joints. μMRI observations suggested an increased volume of the upper articular cavity, an indicator of an inflammatory process. Fibroblast-like synoviocytes (FLSs) isolated from the TMJ of K/BxN mice secreted inflammatory cytokines (IL-6 and IL-1β) and expressed degradative mediators such as matrix metalloproteinases (MMPs). K/BxN mice represent an attractive model for describing and investigating spontaneous damage to the TMJ, a painful disorder in humans with an etiology that is still poorly understood.

The volume estimation and 3D reconstructions were obtained with 3D Slicer.

Comparison of synovial fluid volume of K/BxN and control TMJs. Magnetic resonance imaging (MRI) and 3D reconstructions of the TMJ of a K/BxN mouse (a) and a control mouse (b). c Volume measurement of the upper articular cavity of seven K/BxN mice and three control mice. The orange square represents the K/BxN mouse shown in a, and the green circle represents the control mouse shown in b.

Synchrotron Radiation-Based Reconstruction of the Human Spiral Ganglion: Implications for Cochlear Implantation

Publication: Ear Hear. 2020 Jan/Feb;41(1):173-81. PMID: 31008733

Authors: Li H, Schart-Morén N, Rohani SA, Ladak HM, Rask-Andersen H, Agrawal S.

Institution: Department of Surgical Sciences, Head and Neck Surgery, Section of Otolaryngology, Uppsala University Hospital, Uppsala, Sweden.

Abstract:

OBJECTIVE: To three-dimensionally reconstruct Rosenthal's canal (RC) housing the human spiral ganglion (SG) using synchrotron radiation phase-contrast imaging (SR-PCI). Straight cochlear implant electrode arrays were inserted to better comprehend the electro-cochlear interface in cochlear implantation (CI).

DESIGN: SR-PCI was used to reconstruct the human cochlea with and without cadaveric CI. Twenty-eight cochleae were volume rendered, of which 12 underwent cadaveric CI with a straight electrode via the round window (RW). Data were input into the 3D Slicer software program and anatomical structures were modeled using a threshold paint tool.

RESULTS: The human RC and SG were reproduced three-dimensionally with artefact-free imaging of electrode arrays. The anatomy of the SG and its relationship to the sensory organ (Corti) and soft and bony structures were assessed.

CONCLUSIONS: SR-PCI and computer-based three-dimensional reconstructions demonstrated the relationships among implanted electrodes, angular insertion depths, and the SG for the first time in intact, unstained, and nondecalcified specimens. This information can be used to assess stimulation strategies and future electrode designs, as well as create place-frequency maps of the SG for optimal stimulation strategies of the human auditory nerve in CI.

Visualization of Mucosal Field in HPV Positive and Negative Oropharyngeal Squamous Cell Carcinomas: Combined Genomic and Radiology Based 3D Model

Publication: Sci Rep. 2020 Jan 8;10(1):40. PMID: 31913295 | PDF

Authors: Orosz E, Gombos K, Petrevszky N, Csonka D, Haber I, Kaszas B, Toth A, Molnar K, Kalacs K, Piski Z, Gerlinger I, Burian A, Bellyei S, Szanyi I.

Institution: University of Pécs, Medical School, Department of Otorhinolaryngology, Pécs, Hungary.

Abstract: The aim of this study was to visualize the tumor propagation and surrounding mucosal field in radiography-based 3D model for advanced stage HNSCC and combine it with HPV genotyping and miRNA expression characterization of the visualized area. 25 patients with T1-3 clinical stage HNSCC were enrolled in mapping biopsy sampling. Biopsy samples were evaluated for HPV positivity and miR-21-5p, miR-143, miR-155, miR-221-5p expression in Digital Droplet PCR system. Significant miRNA expression differences of HPV positive tumor tissue biopsies were found for miR-21-5p, miR-143 and miR-221-5p compared to the HPV negative tumor biopsy series. Peritumoral mucosa showed patchy pattern alterations of miR-21-5p and miR-155 in HPV positive cases, while gradual change of miR-21-5p and miR-221-5p was seen in HPV negative tumors. In our study we found differences of the miRNA expression patterns among the HPV positive and negative tumorous tissues as well as the surrounding mucosal fields. The CT based 3D models of the cancer field and surrounding mucosal surface can be utilized to improve proper preoperative planning. Complex evaluation of HNSCC tissue organization field can elucidate the clinical and molecular differentiation of HPV positive and negative cases, and enhance effective organ saving therapeutic strategies.
"Using the segment editor module of 3D Slicer 4.1 sofware 3D segmentation of the tumor was created according to the delineation. Using the same module, the 3D segmentation of the air inside the pharynx was created as well. Using the margin and hollow tools a 1mm thick boundary was created from the segmentation of the air in order to model the mucous membrane."

HR CT image and 3D model of a HPV negative stage T3 tonsillar squamous cell carcinoma. Tumor mass is marked red on the horizontal, sagittal and frontal planes in all sections and a 3D model is built up based on the CT segments on the upper right quarter of the picture.

Using of a Dismountable 3D-model of the Collecting System with Color Segmentation to Improve the Learning Curve of Residents

Publication: Urologiia. 2020 Jan;(6):21-5. PMID: 32003162

Authors: Guliev BG, Komyakov BK, Talyshinskiy AE, Stetsik EO.

Institution: Department of Urology of FGBOU VO North-Western State Medical University named after I.I. Mechnikov, Saint Petersburg, Russia.

Abstract:

AIM: to determine the efficiency of using a non-biological dismountable 3D-model of the collecting system with color segmentation for better understanding of its anatomy by residents and to determine the optimal tactics of percutaneous nephrolithotomy (PNL).

MATERIALS AND METHODS: 3D-models of the collecting system were developed based on CT data of 5 patients with staghorn stones, for whom PNL was planned. CT images were obtained in the Dicom format. RadiAnt DICOM Viewer was used for delineation and segmentation of the collecting system with 3D visualization. Using 3D Slicer v.4.8.1 software, virtual models were processed to convert DICOM files to STL format. Then, virtual color extraction of each group of calyxes was performed for convenient disassembling and intraluminal study of the anatomy of the collecting system. The final stage included the printing of each area by the method of layer-by-layer deposition using a 3D printer Picaso designer X. To assess the efficiency of the dismountable 3D-model that simulates a certain collecting system, a questionnaire was used. It allowed to evaluate the understanding of the anatomy of the collecting system by residents, as well as the ability to determine the optimal calyx for PNL by comparing the answers with the result of a survey of practicing urologists who had performed more than 50 cases.

RESULTS: After studying 3D-models by residents, determination of the number of calyxes in each group was not statistically significantly different from those for practicing urologists who used CT images. The choice of the calyx for primary puncture was not different between groups. However, residents chose the calyx for additional access worse (p=0.009).

CONCLUSION: The dismountable 3D-model of the collecting system is promising for training of residents and planning PNL. Studying the anatomy of a single group of calyxes as well as the entire collecting system allows to choose the optimal calyx for percutaneous puncture during PNL.

Manual and Semiautomatic Segmentation of Bone Sarcomas on MRI Have High Similarity

Publication: Braz J Med Biol Res. 2020 Jan 31;53(2):e8962. PMID: 32022102 | PDF

Authors: Dionísio FCF, Oliveira LS, Hernandes MA, Engel EE, Rangayyan RM, Azevedo-Marques PM, Nogueira-Barbosa MH.

Institution: Departamento de Imagens Médicas, Hematologia e Oncologia Clínica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brasil.

Abstract: The aims of this study were to evaluate the intra- and interobserver reproducibility of manual segmentation of bone sarcomas in magnetic resonance imaging (MRI) studies and to compare manual and semiautomatic segmentation methods. This retrospective study included twelve osteosarcoma and eight Ewing sarcoma MRI studies performed prior to any therapeutic intervention. All cases were histopathologically confirmed. Three radiologists used 3D Slicer software to perform manual segmentation of bone sarcomas in a blinded and independent manner. One radiologist segmented manually and also performed semiautomatic segmentation with the GrowCut tool. Segmentation exercises were timed for comparison. The dice similarity coefficient (DSC) and Hausdorff distance (HD) were used to evaluate similarity between the segmentation results and further statistical analyses were performed to compare DSC, HD, and volumetric results. Manual segmentation was reproducible with intraobserver DSC varying from 0.83 to 0.97 and HD from 3.37 to 28.73 mm. Interobserver DSC of manual segmentation showed variation from 0.73 to 0.97 and HD from 3.93 to 33.40 mm. Semiautomatic segmentation compared to manual segmentation resulted in DSCs of 0.71-0.96 and HDs of 5.38-31.54 mm. Semiautomatic segmentation required significantly less time compared to manual segmentation (P value ≤0.05). Among all situations compared, tumor volumetry did not show significant statistical differences (P value >0.05). We found excellent intra- and interobserver agreement for manual segmentation of osteosarcoma and Ewing sarcoma. There was high similarity between manual and semiautomatic segmentation, with a significant reduction of segmentation time using the semiautomatic method.

3D Slicer’s GrowCut semiautomatic segmentation steps of a femoral osteosarcoma magnetic resonance imaging case. In the first column (A, B, and C), the T1WI sequence images are on the left and the T1WI FS GD sequence images are on the right. In the second (D, E, and F) and third columns (G and H), there are only T1WI FS GD sequence images. A, Yellow rectangular area of background tissue beyond the inferior margin of tumor. B and C, Area of interest from the tumor tissue within green mark and background tissue within yellow mark in the extremities of the tumor (B) and in the middle portion of the tumor on the longitudinal axis (C). D, E, and F, Segmented volume of interest within green mark after GrowCut tool processing in coronal (D), axial (E), and sagittal (F) planes. G and H, Manual editing of GrowCut tool excluding areas from the volume of interest (within green mark) that do not contain tumor tissue, as indicated with the blue arrow in (G), and including areas with tumor tissue in the volume of interest, as shown in area marked in red (H).

Measurement Error and Reliability of Three Available 3D Superimposition Methods in Growing Patients

Publication: Head Face Med. 2020 Jan 27;16(1):1. PMID: 31987041 | PDF

Authors: Ponce-Garcia C, Ruellas ACO, Cevidanes LHS, Flores-Mir C, Carey JP, Lagravere-Vich M.

Institution: Division of Orthodontics, School of Dentistry, University of Alberta, Edmonton, Canada.

Abstract: Cone-Beam Computed Tomography (CBCT) images can be superimposed, allowing three-dimensional (3D) evaluation of craniofacial growth/treatment effects. Limitations of 3D superimposition techniques are related to imaging quality, software/hardware performance, reference areas chosen, and landmark points/volumes identification errors. The aims of this research are to determine/compare the intra-rater reliability generated by three 3D superimposition methods using CBCT images, and compare the changes observed in treated cases by these methods.

METHODS: Thirty-six growing individuals (11-14 years old) were selected from patients that received orthodontic treatment. Before and after treatment (average 24 months apart) CBCTs were analyzed using three superimposition methods. The superimposed scans with the two voxel-based methods were used to construct surface models and quantify differences using 3D SlicerCMF software, while distances in the landmark-derived method were calculated using Excel. 3D linear measurements of the models superimposed with each method were then compared.

RESULTS: Repeated measurements with each method separately presented good to excellent intraclass correlation coefficient (ICC ≥ 0.825). ICC values were the lowest when comparing the landmark-based method and both voxel-based methods. Moderate to excellent agreement was observed when comparing the voxel-based methods against each other. The landmark-based method generated the highest measurement error.

CONCLUSIONS: Findings indicate good to excellent intra-examiner reliability of the three 3D superimposition methods when assessed individually. However, when assessing reliability among the three methods, ICC demonstrated less powerful agreement. The measurements with two of the three methods (CMFreg/3D Slicer and Dolphin) showed similar mean differences; however, the accuracy of the results could not be determined.

Color-coded map with CMFreg/3D Slicer method for visualization purposes only, not quantitative assessment. Frontal (4a) and 45 degrees (4b) views of the 3D color-coded maps showing the change in mm.

Prostate Multiparametric Magnetic Resonance Imaging Features Following Partial Gland Cryoablation

Publication: Urology. Urology. 2020 Apr;138:98-105. PMID: 31954170

Authors: Al Awamlh BAH, Margolis DJ, Gross MD, Natarajan S, Priester A, Hectors S, Ma X, Mosquera JM, Liao J, Hu JC.

Institution: Department of Urology, New York Presbyterian Hospital, Weill Cornell Medicine, New York, NY.

Abstract: OBJECTIVES: To assess the qualitative and quantitative changes on prostate multiparametric magnetic resonance imaging (mpMRI) following partial gland ablation (PGA) with cryotherapy and correlate with histopathology.

METHODS: We used 3D Slicer to generate prostate models and segment ipsilateral (treated) and contralateral peripheral and transition zones in ten men who underwent MRI/transrectal ultrasound fusion-guided PGA during 2017-2018. Pre and post-PGA volumes of prostate segments were compared. Post-PGA mpMRI were categorized according to PI-RADS v2 and treatment response on mpMRI was assessed in a manner similar to the radiology evaluation framework following liver lesion ablation.

RESULTS: Median volume of ipsilateral peripheral and transition zones decreased from 10.9 mL and 13.0 mL to 7.2 mL and 10.8 mL (p=0.005), respectively. Median volume of contralateral peripheral and transition zones also decreased from 12.1 mL and 12.5 mL to 9.9 mL to 10.4 mL (p=0.005), respectively. Five men had clinically significant disease (Grade group ≥2) on post-PGA biopsy (three within treatment field and two outside). Of the men with clinically significant prostate cancer, mpMRI revealed PI-RADS 3 lesions in two. However, the treatment response framework did not detect residual disease.

CONCLUSION: PGA results in asymmetric and significant reductions in prostate volume. Our results highlight the need for a separate assessment framework to enable standardization of the interpretation and reporting of post-PGA surveillance mpMRI. Moreover, our findings have significant implications for MRI-targeted surveillance biopsy following PGA with cryotherapy.

3D Printing Method for Next-Day Acetabular Fracture Surgery Using a Surface Filtering Pipeline: Feasibility and 1-Year Clinical Results

Publication: Int J Comput Assist Radiol Surg. 2020 Jan 2. PMID: 31897965

Authors: Weidert S, Andress S, Linhart C, Suero EM, Greiner A, Böcker W, Kammerlander C, Becker CA.

Institution: Department of General, Trauma and Reconstructive Surgery, University Hospital, LMU Munich, Campus Großhadern, Munich, Germany.

Abstract:

INTRODUCTION: In orthopedic surgery, 3D printing is a technology with promising medical applications. Publications show promising results in acetabular fracture surgery over the last years using 3D printing. However, only little information about the workflow and circumstances of how to properly derive the 3D printed fracture model out of a CT scan is published.

MATERIALS AND METHODS: We conducted a retrospective analysis of patients with acetabular fractures in a level 1 trauma center. DICOM data were preoperatively used in a series of patients with acetabular fractures. The 3D mesh models were created using 3D Slicer with a newly introduced surface filtering method. The models were printed using PLA material with FDM printer. After reduction in the printed model, the acetabular reconstruction plate was bent preoperatively and sterilized. A clinical follow-up after 12 months in average was conducted with the patients.

RESULTS: In total, 12 patients included. Mean printing time was 8:40 h. The calculated mean printing time without applying the surface filter was 25:26 h. This concludes an average printing time reduction of 65%. Mean operation time was 3:16 h, and mean blood loss was 853 ml. Model creation time was about 11 min, and mean printing time of the 3D model was 8:40 h, preoperative model reduction time was 5 min on average, and preoperative bending of the plate took about 10 min. After 12 months, patients underwent a structured follow-up. Harris Hip Score was 75.7 points, the Modified Harris Hip Score 71.6 points and the Merle d'Aubigne Score 11.1 points on average.

CONCLUSIONS: We presented the first clinical practical technique to use 3D printing in acetabular fracture surgery. By introducing a new surface filtering pipeline, we reduced printing time and cost compared to the current literature and the state of the art. Low costs and easy handling of the 3D printing workflow make it usable in nearly every hospital setting for acetabular fracture surgery.

Funding:

  • FöFoLe Reg.Nr.. 935/Medizinischen Fakultät, Ludwig-Maximilians-Universität München

Convolutional Neural Network-based MR Image Analysis for Alzheimer's Disease Classification

Publication: Curr Med Imaging Rev. 2020;16(1):27-35. PMID: 31989891

Authors: Choi BK, Madusanka N, Choi HK, So JH, Kim CH, Park HG, Bhattacharjee S, Prakash D.

Institution: Department of Digital Anti-Aging Healthcare, u-AHRC, Inje University, Gimhae, Korea.

Abstract:

BACKGROUND: In this study, we used a convolutional neural network (CNN) to classify Alzheimer's disease (AD), mild cognitive impairment (MCI), and normal control (NC) subjects based on images of the hippocampus region extracted from magnetic resonance (MR) images of the brain.

METHODS: The datasets used in this study were obtained from the Alzheimer's Disease Neuroimaging Initiative (ADNI). To segment the hippocampal region automatically, the patient brain MR images were matched to the International Consortium for Brain Mapping template (ICBM) using 3D-Slicer software. Using prior knowledge and anatomical annotation label information, the hippocampal region was automatically extracted from the brain MR images.

RESULTS: The area of the hippocampus in each image was preprocessed using local entropy minimization with a bi-cubic spline model (LEMS) by an inhomogeneity intensity correction method. To train the CNN model, we separated the dataset into three groups, namely AD/NC, AD/MCI, and MCI/NC. The prediction model achieved an accuracy of 92.3% for AD/NC, 85.6% for AD/MCI, and 78.1% for MCI/NC.

CONCLUSION: The results of this study were compared to those of previous studies, and summarized and analyzed to facilitate more flexible analyses based on additional experiments. The classification accuracy obtained by the proposed method is highly accurate. These findings suggest that this approach is efficient and may be a promising strategy to obtain good AD, MCI and NC classification performance using small patch images of hippocampus instead of whole slide images.


Go to 2020 :: 2019 :: 2018 :: 2017 :: 2016 :: 2015 :: 2014-2011:: 2010-2005