Difference between revisions of "Documentation/4.2/Extensions/SlicerRT"
(Plastimatch modules added) |
|||
Line 25: | Line 25: | ||
*[[Documentation/{{documentation/version}}/Modules/Isodose|Isodose line and surface display]] | *[[Documentation/{{documentation/version}}/Modules/Isodose|Isodose line and surface display]] | ||
+ | <!-- ---------------------------- --> | ||
+ | {{documentation/{{documentation/version}}/extension-section|Plastimatch}} | ||
+ | |||
+ | Plastimatch is an open source software with focus is high-performance volumetric registration of medical images. Plastimatch extensions are delivered together with SlicerRt. | ||
− | + | *[[Documentation/{{documentation/version}}/Modules/PlmBSplineDeformableRegistration|Deformable image registration]] | |
− | + | *[[Documentation/{{documentation/version}}/Modules/PlmDICOMRTImport|Plastimatch DICOM-RT import]] | |
− | + | *[[Documentation/{{documentation/version}}/Modules/PlmDICOMRTExport|Plastimatch DICOM-RT export]] [[image:UnderConstruction.png|tumb|10px]] | |
− | + | *[[Documentation/{{documentation/version}}/Modules/PlmLANDWARP|Landmark-based deformable image registration]] | |
− | + | *[[Documentation/{{documentation/version}}/Modules/PlmXFORMWARP|Image warping]] [[image:UnderConstruction.png|tumb|10px]] | |
− | |||
<!-- | <!-- | ||
**[[Documentation/{{documentation/version}}/Modules/PlmDoseComparison|Plastimatch Dose Comparison]] (Greg Sharp)[[image:UnderConstruction.png|tumb|10px]] | **[[Documentation/{{documentation/version}}/Modules/PlmDoseComparison|Plastimatch Dose Comparison]] (Greg Sharp)[[image:UnderConstruction.png|tumb|10px]] | ||
Line 53: | Line 56: | ||
* Tutorial presentation: [https://www.assembla.com/spaces/slicerrt/documents/aAuMq81Eqr4ztvacwqjQXA/download/aAuMq81Eqr4ztvacwqjQXA available on the SlicerRT website] | * Tutorial presentation: [https://www.assembla.com/spaces/slicerrt/documents/aAuMq81Eqr4ztvacwqjQXA/download/aAuMq81Eqr4ztvacwqjQXA available on the SlicerRT website] | ||
* Sample data: [https://www.assembla.com/spaces/slicerrt/documents/bMuwgYTKur4yP-acwqjQWU/download/bMuwgYTKur4yP-acwqjQWU available on the SlicerRT website] | * Sample data: [https://www.assembla.com/spaces/slicerrt/documents/bMuwgYTKur4yP-acwqjQWU/download/bMuwgYTKur4yP-acwqjQWU available on the SlicerRT website] | ||
− | |||
− | |||
− | |||
− | |||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/extension-section|References}} | {{documentation/{{documentation/version}}/extension-section|References}} | ||
* [https://www.assembla.com/spaces/slicerrt/wiki/SlicerRt_users_guide SlicerRT users guide pages] | * [https://www.assembla.com/spaces/slicerrt/wiki/SlicerRt_users_guide SlicerRT users guide pages] | ||
+ | * [https://plastimatch.org/contents.html Plastimatch documentation] | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> |
Revision as of 02:48, 6 November 2012
Home < Documentation < 4.2 < Extensions < SlicerRT
Introduction and Acknowledgements
Authors: Csaba Pinter (PerkLab, Queen's University), Andras Lasso (PerkLab, Queen's University), Kevin Wang (Radiation Medicine Program, Princess Margaret Hospital, University Health Network Toronto)
Contact: Andras Lasso, <email>lasso@cs.queensu.ca</email>
Website: https://www.assembla.com/spaces/slicerrt
License: Slicer license
Extension Description
SlicerRT is one of the themes of the SparKit (Software Platform and Adaptive Radiotherapy Kit) project with the goal of making 3D Slicer a powerful radiotherapy research platform. SparKit is a project funded by Cancer Care Ontarioand the Ontario Consortium for Adaptive Interventions in Radiation Oncology (OCAIRO) to provide free, open-source toolset for radiotherapy and related image-guided interventions.
Modules
- DICOM-RT import
- Contours
- Dose volume histogram
- Dose accumulation
- Dose comparison
- Isodose line and surface display
Plastimatch
Plastimatch is an open source software with focus is high-performance volumetric registration of medical images. Plastimatch extensions are delivered together with SlicerRt.
- Deformable image registration
- Plastimatch DICOM-RT import
- Plastimatch DICOM-RT export
- Landmark-based deformable image registration
- Image warping
Use Cases
- Comparison of dose maps and dose volume histograms from various treatment planning systems
- Evaluation the effect of image-based non-rigid patient motion compensation
- Dose accumulation with motion compensation
Tutorials
- Tutorial presentation: available on the SlicerRT website
- Sample data: available on the SlicerRT website
References
Information for Developers
Section under construction. |