Module Description
T1 mapping estimates effective tissue parameter maps (T1) from multi-spectral FLASH MRI scans with different flip angles. T1 mapping can be used to optimize parameters for a sequence, monitor diseased tissue, measure Ktrans in DCE-MRI and etc.
The method and equations for Variable Flip Angle T1 Mapping are available here: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3620726/pdf/nihms-423474.pdf
Use Cases
- Take multi-spectral FLASH images with an arbitrary number of flip angles as input, and estimate the T1 values of the data for each voxel.
- Read repetition time(TR), echo time(TE) and flip angles from the Dicom header directly.
- Prostate, brain, head & neck, cervix, breast and etc.
Sample Results of T1 Mapping
|
Comparison of Different T1 Mapping Tools
|
Tutorials
Panels and their use
|
- Input
- Input image: Multivolume node containing multiple flip angles image loaded using DICOM module
- Model: VFA, Variable Flip Angle
- Input mask: Segmentation of the region of interest (optional); if specified, model fitting will be performed only within the specified mask
- Flip Angles to include: List of Flip Angles that should be used in the fitting process (optional); this parameter is used only if not empty
- Flip Angles to exclude: List of Flip Angles that should NOT be used in the fitting process (optional); this parameter is used only if not empty
- Output common to all models
- Fitted volume: Multi-volume containing the fitted model sampled at the Flip Angles of the input dataset (optional)
- Quality of fit volume: R-squared (optional)
- VFA model output
- T1 Map: T1 mapping result calculated at each voxel
|
Similar Modules
References
Information for Developers
Source code: https://github.com/QIICR/T1Mapping