Slicer Registration Library Case #12: Liver Tumor Cryoablation

Input

this is a pre-op CT + contrast reference image. All images are aligned into this space lleft this is the pre-op MRI we seek to align with the CT
fixed image/target moving image

Slicer4 Modules used

Download (from NAMIC MIDAS)

Why 2 sets of files? The "input data" mrb includes only the unregistered data to try the method yourself from start to finish. The full dataset includes intermediate files and results (transforms, resampled images etc.). If you use the full dataset we recommend to choose different names for the images/results you create yourself to distinguish the old data from the new one you generated yourself.

Objective / Background

We seek to align a pre-operative MRI with a contrast enhanced CT for surgical guidance.

Keywords

MRI, CT, IGT, intra-operative, liver, cryoablation, change detection, non-rigid registration

Input Data

  • reference/fixed : pr-op CT, 0.95 x 0.95 x 5 mm voxel size
  • moving: intra-op MRI, 0.78 x 0.78 x 2.5 mm axial,