Difference between revisions of "Documentation:Nightly:Registration:RegistrationLibrary:RegLib C12"
From Slicer Wiki
Line 17: | Line 17: | ||
== Download (from NAMIC MIDAS) == | == Download (from NAMIC MIDAS) == | ||
<small>''Why 2 sets of files? The "input data" mrb includes only the unregistered data to try the method yourself from start to finish. The full dataset includes intermediate files and results (transforms, resampled images etc.). If you use the full dataset we recommend to choose different names for the images/results you create yourself to distinguish the old data from the new one you generated yourself. ''</small> | <small>''Why 2 sets of files? The "input data" mrb includes only the unregistered data to try the method yourself from start to finish. The full dataset includes intermediate files and results (transforms, resampled images etc.). If you use the full dataset we recommend to choose different names for the images/results you create yourself to distinguish the old data from the new one you generated yourself. ''</small> | ||
− | *[http://slicer.kitware.com/midas3/download/?items=95490 ''' | + | *[http://slicer.kitware.com/midas3/download/?items=95490 '''RegLib_12.mrb''': input data only, use this to run the tutorial from the start <small>(Slicer mrb file. 35 MB). </small>] |
− | *[http://slicer.kitware.com/midas3/download/?items=95491 ''' | + | *[http://slicer.kitware.com/midas3/download/?items=95491 '''RegLib_C12_full.mrb''': includes raw data + all solutions and intermediate files, use to browse/verify <small>(Slicer mrb file. 68 MB). </small>] |
===Objective / Background === | ===Objective / Background === |
Revision as of 18:29, 30 June 2013
Home < Documentation:Nightly:Registration:RegistrationLibrary:RegLib C12Contents
Slicer Registration Library Case #12: Liver Tumor Cryoablation
Input
fixed image/target | moving image |
Slicer4 Modules used
Download (from NAMIC MIDAS)
Why 2 sets of files? The "input data" mrb includes only the unregistered data to try the method yourself from start to finish. The full dataset includes intermediate files and results (transforms, resampled images etc.). If you use the full dataset we recommend to choose different names for the images/results you create yourself to distinguish the old data from the new one you generated yourself.
- RegLib_12.mrb: input data only, use this to run the tutorial from the start (Slicer mrb file. 35 MB).
- RegLib_C12_full.mrb: includes raw data + all solutions and intermediate files, use to browse/verify (Slicer mrb file. 68 MB).
Objective / Background
We seek to align a pre-operative MRI with a contrast enhanced CT for surgical guidance.
Keywords
MRI, CT, IGT, intra-operative, liver, cryoablation, change detection, non-rigid registration
Input Data
- reference/fixed : pr-op CT, 0.95 x 0.95 x 5 mm voxel size
- moving: intra-op MRI, 0.78 x 0.78 x 2.5 mm axial,