Difference between revisions of "Documentation/Nightly/Modules/LAScarSegmenter"
Liangjiazhu (talk | contribs) |
Liangjiazhu (talk | contribs) |
||
Line 43: | Line 43: | ||
The IO section has two input (Original Image and Endocardium Label Image) and one output. | The IO section has two input (Original Image and Endocardium Label Image) and one output. | ||
+ | |||
+ | <!-- ---------------------------- --> | ||
+ | {{documentation/{{documentation/version}}/module-section|References}} | ||
+ | *Y. Gao, L. Zhu, A. Yezzi, S. Bouix , A. Tannenbaum. Scar Segmentation in DE-MRI, IEEE International Symposium on Biomedical Imaging (ISBI) , 2012. | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|Information for Developers}} | {{documentation/{{documentation/version}}/module-section|Information for Developers}} | ||
{{documentation/{{documentation/version}}/module-developerinfo}} | {{documentation/{{documentation/version}}/module-developerinfo}} | ||
− | |||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-footer}} | {{documentation/{{documentation/version}}/module-footer}} | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> |
Revision as of 03:09, 15 June 2013
Home < Documentation < Nightly < Modules < LAScarSegmenter
For the latest Slicer documentation, visit the read-the-docs. |
Introduction and Acknowledgements
This work is part of the National Alliance for Medical Image Computing (NA-MIC), funded by the National Institutes of Health through the NIH Roadmap for Medical Research, Grant U54 EB005149. Information on NA-MIC can be obtained from the NA-MIC website. Contributor: LiangJia Zhu, University of Alabama at Birmingham | |||||||||
|
Tutorials
- Load source image
- Load endocardium label image. Pulmonary veins need to be excluded from this label image
- Select Segmentation->Left Atrial Segmentation module
- Choose the source and label image. Create/select an output image.
- Press the Apply button
Panels and their use
The panel of this module is as follows:
The IO section has two input (Original Image and Endocardium Label Image) and one output.
References
- Y. Gao, L. Zhu, A. Yezzi, S. Bouix , A. Tannenbaum. Scar Segmentation in DE-MRI, IEEE International Symposium on Biomedical Imaging (ISBI) , 2012.
Information for Developers
Section under construction. |