Difference between revisions of "Documentation/Nightly/Extensions/SlicerRT"
From Slicer Wiki
(4.1 -> Nightly) |
(Copied from 4.2 (which was just updated)) |
||
Line 18: | Line 18: | ||
{{documentation/{{documentation/version}}/extension-section|Modules}} | {{documentation/{{documentation/version}}/extension-section|Modules}} | ||
− | |||
− | |||
− | |||
− | |||
*[[Documentation/{{documentation/version}}/Modules/DicomRtImport|DICOM-RT import]] | *[[Documentation/{{documentation/version}}/Modules/DicomRtImport|DICOM-RT import]] | ||
+ | *[[Documentation/{{documentation/version}}/Modules/Contours|Contours]] | ||
*[[Documentation/{{documentation/version}}/Modules/DoseVolumeHistogram|Dose volume histogram]] | *[[Documentation/{{documentation/version}}/Modules/DoseVolumeHistogram|Dose volume histogram]] | ||
*[[Documentation/{{documentation/version}}/Modules/DoseAccumulation|Dose accumulation]] | *[[Documentation/{{documentation/version}}/Modules/DoseAccumulation|Dose accumulation]] | ||
− | *[[Documentation/{{documentation/version}}/Modules/DoseComparison|Dose comparison | + | *[[Documentation/{{documentation/version}}/Modules/DoseComparison|Dose comparison]] |
− | *[[Documentation/{{documentation/version}}/Modules/Isodose|Isodose line and surface display ( | + | *[[Documentation/{{documentation/version}}/Modules/Isodose|Isodose line and surface display]] |
+ | |||
+ | |||
+ | * Modules from [[Documentation/{{documentation/version}}/Extensions/Plastimatch|Plastimatch]] (Greg Sharp) | ||
+ | **[[Documentation/{{documentation/version}}/Modules/PlmBSplineDeformableRegistration|Plastimatch Automatic deformable image registration]] (Greg Sharp) | ||
+ | **[[Documentation/{{documentation/version}}/Modules/PlmDICOMRTImport|Plastimatch DICOM-RT import]] (Greg Sharp) | ||
+ | **[[Documentation/{{documentation/version}}/Modules/PlmDICOMRTExport|Plastimatch DICOM-RT export]] (Greg Sharp)[[image:UnderConstruction.png|tumb|10px]] | ||
+ | **[[Documentation/{{documentation/version}}/Modules/PlmLANDWARP|Plastimatch LANDWARP Landmark]] (Greg Sharp) | ||
+ | **[[Documentation/{{documentation/version}}/Modules/PlmXFORMWARP|Plastimatch XFORMWARP]] (Greg Sharp)[[image:UnderConstruction.png|tumb|10px]] | ||
+ | <!-- | ||
+ | **[[Documentation/{{documentation/version}}/Modules/PlmDoseComparison|Plastimatch Dose Comparison]] (Greg Sharp)[[image:UnderConstruction.png|tumb|10px]] | ||
+ | **[[Documentation/{{documentation/version}}/Modules/PlmDoseVolumeHistogram|Plastimatch Dose Volume Histogram]] (Greg Sharp)[[image:UnderConstruction.png|tumb|10px]] | ||
+ | **[[Documentation/{{documentation/version}}/Modules/PlmSyntheticImageGeneration|Plastimatch Synthetic Image Generation]] (Greg Sharp)[[image:UnderConstruction.png|tumb|10px]] | ||
+ | **[[Documentation/{{documentation/version}}/Modules/PlmThreshBox|Plastimatch Threshold in a box]] (Greg Sharp)[[image:UnderConstruction.png|tumb|10px]] | ||
--> | --> | ||
Revision as of 20:57, 2 November 2012
Home < Documentation < Nightly < Extensions < SlicerRTIntroduction and Acknowledgements
Authors: Csaba Pinter (PerkLab, Queen's University), Andras Lasso (PerkLab, Queen's University), Kevin Wang (Radiation Medicine Program, Princess Margaret Hospital, University Health Network Toronto)
Contact: Andras Lasso, <email>lasso@cs.queensu.ca</email>
Website: https://www.assembla.com/spaces/slicerrt
License: Slicer license
Extension Description
SlicerRT is one of the themes of the SparKit (Software Platform and Adaptive Radiotherapy Kit) project with the goal of making 3D Slicer a powerful radiotherapy research platform. SparKit is a project funded by Cancer Care Ontarioand the Ontario Consortium for Adaptive Interventions in Radiation Oncology (OCAIRO) to provide free, open-source toolset for radiotherapy and related image-guided interventions.
Modules
- DICOM-RT import
- Contours
- Dose volume histogram
- Dose accumulation
- Dose comparison
- Isodose line and surface display
- Modules from Plastimatch (Greg Sharp)
- Plastimatch Automatic deformable image registration (Greg Sharp)
- Plastimatch DICOM-RT import (Greg Sharp)
- Plastimatch DICOM-RT export (Greg Sharp)
- Plastimatch LANDWARP Landmark (Greg Sharp)
- Plastimatch XFORMWARP (Greg Sharp)
Use Cases
- Comparison of dose maps and dose volume histograms from various treatment planning systems
- Evaluation the effect of image-based non-rigid patient motion compensation
- Dose accumulation with motion compensation
Tutorials
- Tutorial presentation: available on the SlicerRT website
- Sample data: available on the SlicerRT website
Similar Extensions
- Plastimatch: SlicerRT and Plastimatch are complementary software libraries. Plastimatch focuses on delivering new computational methods radiotherapy, while SlicerRT aims for providing an easy-to-use interface for a wide range of stable, well-tested radiotherapy related features. SlicerRT uses Plastimatch internally for certain operations.
References
Information for Developers
Section under construction. |