Difference between revisions of "Modules:RegistrationMetrics-Documentation-3.6"

From Slicer Wiki
Jump to: navigation, search
Line 64: Line 64:
 
** '''Second output'''
 
** '''Second output'''
 
* '''Viewing panel:'''
 
* '''Viewing panel:'''
|[[Image:SlicerPanel.PNG|thumb|280px|Screen shot of panel for Registration Metrics Module]]]
+
|[[Image:SlicerPanel.PNG|thumb|280px|Screen shot of panel for Registration Metrics Module]]
 
|}
 
|}
  

Revision as of 18:12, 27 April 2010

Home < Modules:RegistrationMetrics-Documentation-3.6

Return to Slicer 3.6 Documentation

Gallery of New Features


Registration Metrics

Screen shot of Registration Metrics module showing an axial slice with a color map representing alignment error between the two label map images
Screen shot of panel for Registration Metrics Module

General Information

Module Type & Category

Type: CLI

Category: Registration

Authors, Collaborators & Contact

  • Haytham Elhawary: Brigham and Women's Hospital, SPL
  • Sota Oguro: Brigham and Women's Hospital, SPL
  • Nobuhiko Hata: Brigham and Women's Hospital, SPL
  • Contact: Nobuhiko Hata, hata [at] bwh.harvard.edu or Haytham Elhawary, elhawary [at] bwh.harvard.edu

Module Description

This module is capable of calculating the 95% Hausdorff distance (HD) and the Dice Similarity Coefficient (DSC) between two label map images. If the two label map images represent registered segmented structures then the 95% HD and DSC will provide a measure of contour and volumetric alignment between the images. The HD is the maximum distance of a set to the nearest point in another set and gives a measure of contour alignment between structures. The DSC gives a measure of the volumetric overlap between the two segmented structures, and indicates twice the number of voxels which are shared by or are common to both structures divided by the total number of non-zero voxels in both structures. The DSC can range from zero to one, where zero is no alignment between images and one is perfect alignment. These two metrics are explained more formally in papers presented in the References section.

Usage

  • Image Volume 1 and Image Volume 2 are two label map images which you wish to load and compare
  • The module will provide the DSC and 95% HD between the two images, and will also provide an output volume. The output volume represents the contour of one of the images with each pixel value representing the Hausdorff Distance to the contour of the other image. Both the DSC and 95% HD will be printed onto the Log viewer in Slicer (can be accessed by clicking on the "X" icon that is located at the bottom right hand corner of the Slicer window) and on the Terminal for operating systems other than Windows.
  • For improved visualization, the output image should be viewed with a color map. The code provides a color map entitled "Matlab_colormap.txt" which should be used for visualization of the output volume. Change the lower bound of the Threshold in the Display panel of the Volume Module to 0.01.

Use Cases, Examples

  • Here are two example label map images, CTlabel.nrrd and Defolabel.nrrd: ExampleData
  • Load them into the RegistrationMetrics Module, which can be found under the Registration category in the Modules menu.
  • The DSC should be 0.959906 and the 95% HD is 3.66408mm, which is printed into the Log Viewer in Slicer and the Terminal
  • An output volume named "Registration Metrics Volume" should be created, which shows the contour of one of the input images.
  • Go to the Module named "Color" and load the text file named "Matlab_colormap.txt", which is provided with the source code of the RegistrationMetrics Module.
  • Go to the Volumes tab, choose "Registration Metrics Volume" as the Active Volume and then in the Display panel, choose "Matlab_colormap.txt" in the Color Select menu.
  • Change threshold to "manual" and make the lower bound of the interval 0.01. Change the Window/Level to make the output volume take on the range of colors from blue to red.
  • The red pixels represent the pixels that have the highest HD with respect to the contour of the other input image. The pixel value shows the HD. This shows which part of the contour is further away (i.e. have highest grade of misalignment) from the contour of the other input image.

Tutorials

There are no tutorials for this module, since it is quite self-explanatory with the information in this wiki page.

Quick Tour of Features and Use

A list panels in the interface, their features, what they mean, and how to use them. For instance:

  • Input panel:
    • First input
    • Second input
  • Parameters panel:
    • First parameter
    • Second parameter
  • Output panel:
    • First output
    • Second output
  • Viewing panel:
Screen shot of panel for Registration Metrics Module

Development

Notes from the Developer(s)

Algorithms used, library classes depended upon, use cases, etc.

Dependencies

Other modules or packages that are required for this module's use.

Tests

On the Dashboard, these tests verify that the module is working on various platforms:

Known bugs

Links to known bugs in the Slicer3 bug tracker


Usability issues

Follow this link to the Slicer3 bug tracker. Please select the usability issue category when browsing or contributing.

Source code & documentation

Links to the module's source code:

Source code:

Doxygen documentation:

More Information

Acknowledgment

Include funding and other support here.

References

Publications related to this module go here. Links to pdfs would be useful.