Difference between revisions of "Slicer3:UIDesign:WorkingProblems:BCAnalysis:Volumetric"
From Slicer Wiki
Line 28: | Line 28: | ||
* Segment largest diameter tumor in baseline '''Question:''' multiple tumors ok? | * Segment largest diameter tumor in baseline '''Question:''' multiple tumors ok? | ||
** Manual or automatic segmentation OK | ** Manual or automatic segmentation OK | ||
− | * Segment tumor in followup '''Questions:''' Must be same tumor, or largest diameter in followup? multiple tumors ok? | + | * Segment tumor in followup '''Questions:''' Must be same tumor, or largest diameter in followup? multiple tumors ok? (same tumor) |
** Manual or automatic segmentation OK -- but use same method | ** Manual or automatic segmentation OK -- but use same method | ||
* Measure: | * Measure: | ||
− | ** Volume(t1) and Volume(t2) '''Question:''' which is preferred, mm^3 | + | ** Volume(t1) and Volume(t2) '''Question:''' which is preferred, mm^3! |
** Relative % difference | ** Relative % difference | ||
** Absolute change (same units as above) | ** Absolute change (same units as above) |
Revision as of 13:14, 6 August 2009
Home < Slicer3:UIDesign:WorkingProblems:BCAnalysis:VolumetricBack to Project Overview
Contents
Volumetric Tumor Analysis for Breast Cancer
Goal
Goal is to accommodate basic RECIST assessment for breast cancer (Response Evaluation Criteria In Solid Tumors). (RECIST is a set of published rules that define when cancer patients improve ("respond"), stay the same ("stable") or worsen ("progression") during treatments).
- Determine features that currently exist in Slicer
- Develop features that don't
- Provide a framework that knits features together in a comfortable workflow.
Linear Measurements Workflow
- Scroll through baseline
- Find the tumor's longest diameter (no reformat, just on orig acquisition)
- Measure the longest diameter D1(t1)
- Measure the orthogonal diameter D2(t1)
- If there are multiple tumors, measure both diams in each tumor and sum to get relative D1(t1) and relative D2(t1)
- Perform same measurements D1(t2) and D2(t2)
- Specific results to report:
- Percent change
- Absolute change
- Question: units for these values -- mm!
Volume Measurements Workflow
- Scroll through dataset and determine tumor with largest diameter.
- Segment largest diameter tumor in baseline Question: multiple tumors ok?
- Manual or automatic segmentation OK
- Segment tumor in followup Questions: Must be same tumor, or largest diameter in followup? multiple tumors ok? (same tumor)
- Manual or automatic segmentation OK -- but use same method
- Measure:
- Volume(t1) and Volume(t2) Question: which is preferred, mm^3!
- Relative % difference
- Absolute change (same units as above)