Introduction and Acknowledgements
Authors: Csaba Pinter (PerkLab, Queen's University), Andras Lasso (PerkLab, Queen's University), Kevin Wang (Radiation Medicine Program, Princess Margaret Hospital, University Health Network Toronto)
Contributors: Greg Sharp (Massachusetts General Hospital), Steve Pieper (Isomics)
Contacts:
- Andras Lasso, <email>lasso@cs.queensu.ca</email>
- Mailing list, <email>slicerrt@alerts.assembla.com</email> (need to register to Assembla using the email address from which the email is sent)
- How to report an error
Website: http://www.slicerrt.org
License: Slicer license
Extension Description
SlicerRT is one of the themes of the SparKit (Software Platform and Adaptive Radiotherapy Kit) project with the goal of making 3D Slicer a powerful radiotherapy research platform. SparKit is a project funded by Cancer Care Ontarioand the Ontario Consortium for Adaptive Interventions in Radiation Oncology (OCAIRO) to provide free, open-source toolset for radiotherapy and related image-guided interventions. The SlicerRT extension incorporates Plastimatch modules and algorithms. |
Modules
- DICOM-RT import
- Contours
- Dose volume histogram
- Dose accumulation
- Dose comparison
- Isodose line and surface display
- Contour comparison
- Contour morphology
- Deformation field visualizer
- Modules from Plastimatch (Greg Sharp)
- Plastimatch Automatic deformable image registration (Greg Sharp)
- Plastimatch DICOM-RT import (Greg Sharp)
- Plastimatch DICOM-RT export (Greg Sharp)
- Plastimatch LANDWARP Landmark (Greg Sharp)
- Plastimatch XFORMWARP (Greg Sharp)
Important note: BSpline Deformable registration and LANDWARP modules do not show up for Slicer 4.2 on Mac
Use Cases
- Comparison of dose maps and dose volume histograms from various treatment planning systems
- Evaluation of the effect of image-based non-rigid patient motion compensation
- Dose accumulation with motion compensation
Tutorials
- Summer NA-MIC week 2012 tutorial
- RSNA 2012 tutorial
- Tutorial description: SlicerRT wiki: Slicer tutorials at RSNA 2012
- Sample data: download SlicerRT ART dose verification data from Midas server
- ECR 2013 - Medical University Vienna workshop
- Workshop material: download from NA-MIC.org
Similar Extensions
- Plastimatch: SlicerRT and Plastimatch are complementary software libraries. Plastimatch focuses on delivering new computational methods radiotherapy, while SlicerRT aims for providing an easy-to-use interface for a wide range of stable, well-tested radiotherapy related features. SlicerRT uses Plastimatch internally for certain operations.
References
Information for Developers
Section under construction. |