Difference between revisions of "Documentation/4.2/Modules/DoseComparison"

From Slicer Wiki
Jump to: navigation, search
(Page created)
 
(Updated according to nightly)
Line 1: Line 1:
This module computes and displays dose comparison metrics.
+
<!-- ---------------------------- -->
 +
{{documentation/{{documentation/version}}/module-header}}
 +
<!-- ---------------------------- -->
  
 +
<!-- ---------------------------- -->
 +
{{documentation/{{documentation/version}}/module-section|Introduction and Acknowledgements}}
 +
{{documentation/{{documentation/version}}/module-introduction-start|{{documentation/modulename}}}}
 +
{{documentation/{{documentation/version}}/module-introduction-row}}
 +
This work is part of the SparKit project, funded by An Applied Cancer Research Unit of Cancer Care Ontario with funds provided by the Ministry of Health and Long-Term Care and the Ontario Consortium for Adaptive Interventions in Radiation Oncology (OCAIRO) to provide free, open-source toolset for radiotherapy and related image-guided interventions.<br>
 +
Author: Csaba Pinter (PerkLab, Queen's University)<br>
 +
Contributor: Greg Sharp (Massachusetts General Hospital)<br>
 +
Contact: Csaba Pinter, <email>pinter@cs.queensu.ca</email><br>
 +
{{documentation/{{documentation/version}}/module-introduction-row}}
 +
{{documentation/{{documentation/version}}/module-introduction-logo-gallery
 +
|{{collaborator|logo|cco}}|{{collaborator|longname|cco}}
 +
|{{collaborator|logo|sparkit}}|{{collaborator|longname|sparkit}}
 +
}}
 +
{{documentation/{{documentation/version}}/module-introduction-end}}
  
[[image:UnderConstruction.png|Under construction|10px]]'''This page is under construction'''[[image:UnderConstruction.png|Under construction|10px]]
+
<!-- ---------------------------- -->
 +
{{documentation/{{documentation/version}}/module-section|Module Description}}
 +
The {{documentation/modulename}} module computes the difference between two co-registered dose volumes using the gamma dose distribution comparison method. This module uses the gamma Plastimatch algorithm internally.
 +
 
 +
<!-- ---------------------------- -->
 +
{{documentation/{{documentation/version}}/module-section|Use Cases}}
 +
Comparing dose distributions
 +
 
 +
{|align="center"
 +
|[[File:SlicerRT0.4 Screenshot Gamma.png|thumb|720px| Dose comparison]]
 +
|}
 +
 
 +
<!-- ---------------------------- -->
 +
{{documentation/{{documentation/version}}/module-section|Tutorials}}
 +
N/A
 +
 
 +
<!-- ---------------------------- -->
 +
{{documentation/{{documentation/version}}/module-section|Panels and their use}}
 +
* Current contour(s): Currently selected contour node (vtkMRMLContourNode) or conotur hierarchy node (vtkMRMLContourHierarchyNode)
 +
* Active representation: The active representation ('''Ribbon model / Indexed labelmap / Closed surface model''') of the selected contour. If a hierarchy is selected in which the active representations of the contained contours do not match, '''Various''' is indicated
 +
* Change active representation: This box contains controls to convert from one representation to another
 +
<!--
 +
{{documentation/{{documentation/version}}/module-parametersdescription}}
 +
-->
 +
 
 +
<!-- ---------------------------- -->
 +
{{documentation/{{documentation/version}}/module-section|Similar Modules}}
 +
N/A
 +
 
 +
<!-- ---------------------------- -->
 +
{{documentation/{{documentation/version}}/module-section|References}}
 +
* Low, D. A.; Harms, W. B.; Mutic, S. & Purdy, J. A. A technique for the quantitative evaluation of dose distributions Med. Phys, 1998, 25 (5), 656/6
 +
* Low, D. A. & Dempsey, J. F. Evaluation of the gamma dose distribution comparison method Med. Phys, 2003, 30 (9), 2455/10
 +
 
 +
<!-- ---------------------------- -->
 +
{{documentation/{{documentation/version}}/module-section|Information for Developers}}
 +
{{documentation/{{documentation/version}}/module-developerinfo}}
 +
 
 +
 
 +
<!-- ---------------------------- -->
 +
{{documentation/{{documentation/version}}/module-footer}}
 +
<!-- ---------------------------- -->

Revision as of 21:52, 8 November 2012

Home < Documentation < 4.2 < Modules < DoseComparison


Introduction and Acknowledgements

This work is part of the SparKit project, funded by An Applied Cancer Research Unit of Cancer Care Ontario with funds provided by the Ministry of Health and Long-Term Care and the Ontario Consortium for Adaptive Interventions in Radiation Oncology (OCAIRO) to provide free, open-source toolset for radiotherapy and related image-guided interventions.
Author: Csaba Pinter (PerkLab, Queen's University)
Contributor: Greg Sharp (Massachusetts General Hospital)
Contact: Csaba Pinter, <email>pinter@cs.queensu.ca</email>

Cancer Care Ontario  
Software Platform and Adaptive Radiotherapy Kit  

Module Description

The DoseComparison module computes the difference between two co-registered dose volumes using the gamma dose distribution comparison method. This module uses the gamma Plastimatch algorithm internally.

Use Cases

Comparing dose distributions

Dose comparison

Tutorials

N/A

Panels and their use

  • Current contour(s): Currently selected contour node (vtkMRMLContourNode) or conotur hierarchy node (vtkMRMLContourHierarchyNode)
  • Active representation: The active representation (Ribbon model / Indexed labelmap / Closed surface model) of the selected contour. If a hierarchy is selected in which the active representations of the contained contours do not match, Various is indicated
  • Change active representation: This box contains controls to convert from one representation to another

Similar Modules

N/A

References

  • Low, D. A.; Harms, W. B.; Mutic, S. & Purdy, J. A. A technique for the quantitative evaluation of dose distributions Med. Phys, 1998, 25 (5), 656/6
  • Low, D. A. & Dempsey, J. F. Evaluation of the gamma dose distribution comparison method Med. Phys, 2003, 30 (9), 2455/10

Information for Developers