Difference between revisions of "EMSegmenter-Tasks:MRI-Human-Brain"

From Slicer Wiki
Jump to: navigation, search
Line 20: Line 20:
  
 
==Atlas==
 
==Atlas==
Atlas was generated based on 82 scans and corresponding segmentations provided by [PNL]. We used Warfield et al. 2001 to register the scans to a preselected template.   
+
Atlas was generated based on 82 scans and corresponding segmentations provided by [http://pnl.bwh.harvard.edu/ Psychiatry Neuroimaging Laboratory, BWH]. We registered the scans to a preselected template via Warfield et al. 2001.   
 
Image Dimension = 256 x 256 x 124 <br>
 
Image Dimension = 256 x 256 x 124 <br>
 
Image Spacing  = 0.9375 x 0.9375 x 0.1.5
 
Image Spacing  = 0.9375 x 0.9375 x 0.1.5

Revision as of 18:09, 30 November 2010

Home < EMSegmenter-Tasks:MRI-Human-Brain

MRI Human Brain

Description

Single channel automatic segmentation of t1w-MRI brain scans into the major tissue classes (gray matter, white matter, csf). The task can only be applied to t1w brain scan showing parts of the skull and neck. The pipeline consist of the following steps:

  • Step 1: Perform image inhomogeneity correction of the MRI scan via N4ITKBiasFieldCorrection (Tustison et al 2010)
  • Step 2: Register the atlas to the MRI scan via BRAINSFit (ask Hans for citation)
  • Step 3: Compute the intensity distributions for each structure
  • Step 4: Automatically segment the MRI scan into the structures of interest using the EM Algorithm (Pohl et al 2007)

Anatomical Tree

  • root
    • background (BG)
      • air (AIR)
      • skull (skull)
    • intracranial cavity (ICC)
      • white matter (WM)
      • grey matter (GM)
      • cerebrospinal fluid (CSF)

Atlas

Atlas was generated based on 82 scans and corresponding segmentations provided by Psychiatry Neuroimaging Laboratory, BWH. We registered the scans to a preselected template via Warfield et al. 2001. Image Dimension = 256 x 256 x 124
Image Spacing = 0.9375 x 0.9375 x 0.1.5

Result

MRI-Human-Brain BeforeAfter.png

Acknowledgment

The construction of the pipeline was supported by funding from NIH NCRR 2P41RR013218 Supplement.

Citations

  • Tustison NJ, Avants BB, Cook PA, Zheng Y, Egan A, Yushkevich PA, Gee JC N4ITK: Improved N3 Bias Correction, IEEE Trans Med Imag, 2010
  • Pohl K, Bouix S, Nakamura M, Rohlfing T, McCarley R, Kikinis R, Grimson W, Shenton M, Wells W. A Hierarchical Algorithm for MR Brain Image Parcellation. IEEE Transactions on Medical Imaging. 2007 Sept;26(9):1201-1212.
  • S. Warfield, J. Rexilius, P. Huppi, T. Inder, E. Miller, W. Wells, G. Zientara, F. Jolesz, and R. Kikinis, “A binary entropy measure to assess nonrigid registration algorithms,” in MICCAI, LNCS, pp. 266–274, Springer, October 2001.