Difference between revisions of "Modules:PlastimatchDICOMRT"
Line 6: | Line 6: | ||
{| | {| | ||
|[[Image:plastimatch_dicomrt_ss.png|thumb|280px|DICOM-RT Structure Set]] | |[[Image:plastimatch_dicomrt_ss.png|thumb|280px|DICOM-RT Structure Set]] | ||
− | |[[Image:plastimatch_dicomrt_dose.png|thumb|280px|DICOM-RT Dose | + | |[[Image:plastimatch_dicomrt_dose.png|thumb|280px|DICOM-RT Dose]] |
|} | |} | ||
Revision as of 20:13, 8 June 2010
Home < Modules:PlastimatchDICOMRTReturn to Slicer 3.6 Documentation
Plastimatch > DICOM-RT Import
General Information
Module Type & Category
Type: CLI
Category: Plastimatch
Authors, Collaborators & Contact
- Authors: See AUTHORS.TXT contained within the package
- Contact: Greg Sharp, Department of Radiation Oncology, Massachusetts General Hospital (gcsharp@partners.org)
- Web page: http://plastimatch.org
Module Description
This is the DICOM-RT structure set import module. It allows you to select a file containing DICOM-RT structure sets, and it creates a 3D Slicer labelmap volume.
Note: In a Slicer labelmap, a voxel can only belong to one structure. However, DICOM-RT allows a region to belong to any number of strucutres. Therefore, importing DICOM-RT structure sets as Slicer labelmaps will usually result in a loss of data. This module uses a "last structure wins" strategy for assigning labels to overlapping volumes.
Note: Because DICOM-RT structures are specified as polylines, there is a small loss of fidelity when they are converted into rasterized volumes. You may minimizing this effect by creating high resolution lablemaps, such as with 1 mm voxels.
Usage
Tutorials
Quick Tour of Features and Use
|
Development
Notes from the Developer(s)
Developer-oriented documentation is found on the plastimatch web site: http://plastimatch.org
Dependencies
This module has no dependencies.
Tests
Plastimatch features approximately 100 test cases.
Known bugs
Usability issues
Please report usability issues to the bug tracker.
Source code & documentation
We recommended to download the latest source code from subversion:
Documentation:
More Information
Acknowledgment
National Institutes of Health
NIH / NCI 6-PO1 CA 21239
Federal share of program income earned by MGH on C06CA059267
Progetto Rocca Foundation
A collaboration between MIT and Politecnico di Milano
References
- G Sharp et al. "Plastimatch - An open source software suite for radiotherapy image processing," Proceedings of the XVIth International Conference on the use of Computers in Radiotherapy, May, 2010.