Register Images
General Information
Module Type & Category
Type: CLI Module calling ITK functions
Category: Registration
Authors, Collaborators & Contact
- Author1: Stephen Aylward, Kitware
- Author2: Casey Goodlett, Kitware
- Contributor1: Ron Kikinis (copying documentation)
- Contact: Casey Goodlett, Kitware
Module Description
This Module is an integrated framework providing access to ITK registration technologies. Algorithms can be run in single mode or pipelined. Depending on the size of the data sets, a significant amount of memory is needed. There is an option to trade off speed for memory. Most of the code is parallelized and will take advantage of multicore capabilities, if available.
New Features in 3.6
- Integration of transform nodes instead of reading/writing to files
- Integration of landmark module for specifying initialization
- Ability to specify a label mask on the fixed image for limiting regions of metric calculation
- Exposed metrics besides Mutual Information
- Simplified parameters
- Ability to include parameter presets distributed with Slicer
Major Features
The major features of the module include:
- Default parameters register many full-head and skull-stripped MRI: rigid, affine, and BSpline
- Offers a complete, pipeline-based registration solution
- Load and apply existing transforms
- Compute rigid, affine, and bspline transforms in sequence with a single command
- Intuitive parameters
- Instead of setting obscure "scales" for parameters, you set global values for "Expected Offset", "Expected Rotation", ... to indicate how much mis-registration is anticipated in the data being registered
- MinimizeMemory option provides a way to compute bspline registrations using a dense set of control points and a large number of samples on "normal" computers (albeit computation time increases)
- SampleFromOverlap option allows images of vastly different sizes to be registered
- Helps to avoid (but does not completely eliminate) the annoying ITK exception, "too many samples falls outside of the image"
- Based on an extensible and re-usable class structure.
Usage
- If you have a large data set or little memory, select the minimize memory option
- If you are planning to use the b-spline registration, be sure to read the discussion of parameter setting in the section below.
Use Cases, Examples
See Registration Use Case project
Quick Tour of Features and Use
See here for more information.
Main Registration Panel
Parameter Choices
- The default parameters should work for a wide range of cases
- In some cases (e.g. unusual acquisition conditions and/or highly inconsistent acquisition protocols) you will need to change the default parameters.
- In other situations, you may wish to tweak parameters to achieve your application-specific speed-vs-accuracy trade-off
See also this page on the NA-MIC wiki about parameter tuning for this module.
Overview
- Step 1: Loaded transform
- You may load a pre-computed transform to initialize the registration.
- If one is loaded, it is immediately applied (i.e., the moving image is resampled)
- Step 2: Initial registration
- Options are:
- None (sets the center of rotation to the center of the moving image)
- Landmark (uses N-pairs of landmarks (passed as vectors) and a least-squared error metric to register the images using a rigid transform
- Image Centers (shifts the images to align their centers)
- Centers of Mass (shifts the images to align their centers of mass)
- Second Moments (shifts and rotates the images to align the 1st and 2nd moments)
- Options are:
- Step 3: Registration
- Options are:
- None (applies the loaded transforms)
- Initial
- computes and applies the initial transform to the loaded registrations)
- Rigid
- computes a rigid transform and then applies it to the loaded registrations
- Affine
- computes an affine transform and then applies it to the loaded registrations
- BSpline
- computes a bspline transform and then applies it to the loaded registrations
- PipelineRigid
- computes a rigid transform (initialized using the results from the initial registration) and then applies it to the loaded registrations
- PipelineAffine
- computes a rigid transform (initialized using the results from the initial registration), uses those results to initialize and compute an affine transform, and then applies it to the loaded registrations
- PipelineBSpline
- computes a rigid transform (initialized using the results from the initial registration), uses those results to initialize and compute an affine transform, and then applies it to the loaded registrations, THEN computes and applies a BSpline transform
- Options are:
Detailed Information
IO Tab
|
Registration Parameters Tab
|
Advanced Registration Parameters Tab
|
Advanced Initial Registration Parameters
|
Advanaced Rigid and Affine Parameters
|
Advanced BSpline Parameters
|
Use Cases
Example 2: Affine Registration
- Task:
- Affine registration of head MRI from two different subjects
- Data:
- Using cases UNC-Healthy-Normal002 (fixed) and UNC-Healthy-Normal004 (moving)
- Data provided by Dr. Bullitt at UNC.
- Data is available from Kitware's MIDAS archive at http://hdl.handle.net/1926/542
- Data can be automatically downloaded into ${RegisterImages_BINARY_DIR}/Testing/Data directory by enabling the CMake variable "BUILD_REGISTER_IMAGES_REAL_WORLD_TESTING"
- Warning this also enables additional tests that can take 4+ hours to complete.
- To see the code for automatically downloading from MIDAS (via svn), see Slicer3/Applications/CLI/RegisterImagesModule/Applications/CMakeLists.txt
Example 3: BSpline Registration
- Task:
- BSpline registration of head MRI from two different subjects
- Data:
- Using cases UNC-Healthy-Normal002 (fixed) and UNC-Healthy-Normal004 (moving)
- Data provided by Dr. Bullitt at UNC.
- Data is available from Kitware's MIDAS archive at http://hdl.handle.net/1926/542
- Data can be automatically downloaded into ${RegisterImages_BINARY_DIR}/Testing/Data directory by enabling the CMake variable "BUILD_REGISTER_IMAGES_REAL_WORLD_TESTING"
- Warning this also enables additional tests that can take 4+ hours to complete.
- To see the code for automatically downloading from MIDAS (via svn), see Slicer3/Applications/CLI/RegisterImagesModule/Applications/CMakeLists.txt
Development
Dependencies
This module makes use of GenerateCLP, MRMLIO and ITK.
- GenerateCLP is used to defined the command-line options. GenerateCLP is distributed with Slicer (/Libs/GenerateCLP).
- MRMLIO is used to replace reading/writing images in ITK to instead passing pointers to shared memory. MRMLIO is distributed with Slicer (/Libs/MRMLIO).
- ITK is used to provide the algorithms. ITK must be compiled with the CMake variables USE_REVIEW, USE_TRANSFORM_IO, and USE_OPTIMIZED_REGISTRATION_METHODS enabled. These options are automatically enabled when ITK is build using Slicer's getBuildTest.tcl script.
Known bugs
- Module may fail (and not report a useful error to the console - check the log files) if insufficient memory is available. If so, please consider enabling the MinimizeMemory option in the Advanced Options tab.
Follow this link to the Slicer3 bug tracker.
Usability issues
Follow this link to the Slicer3 bug tracker. Please select the usability issue category when browsing or contributing.
Source code & documentation
Customize following links for your module.
Links to documentation generated by doxygen.
More Information
Acknowledgment
This work is part of the National Alliance for Medical Image Computing (NAMIC), funded by the National Institutes of Health through the NIH Roadmap for Medical Research, Grant U54 EB005149. Information on the National Centers for Biomedical Computing can be obtained from National Centers for Biomedical Computing.
References
Publications related to this module go here. Links to pdfs would be useful.
- some email about initialization
- ITK Registration optimization
- Slicer2 vs Slicer3 registration validation
- Using BatchMake with Slicer RegisterImages module
Wishlist
- include moving filename into default names of results
- display fixed and moving results in compareview with proper LUTs (different colors for fixed and result, apply w/l from moving to results volume
- use in combination with VOI
- more detailed explanation of how to set parameters
- increase number of example solutions