Difference between revisions of "Documentation/4.8/Modules/GeodesicSlicer"
(24 intermediate revisions by the same user not shown) | |||
Line 19: | Line 19: | ||
* Dr. Olivier Etard, M.D., Ph.D., CHU de Caen. | * Dr. Olivier Etard, M.D., Ph.D., CHU de Caen. | ||
* Dr. Clément Nathou, M.D., Ph.D., CHU de Caen. | * Dr. Clément Nathou, M.D., Ph.D., CHU de Caen. | ||
+ | * Dr. Nicolas Delcroix, Ph.D., UMS 3408. | ||
* Dr. Sonia Dollfus, M.D., Ph.D., CHU de Caen, header of [http://www.ists.cyceron.fr/spip.php?rubrique17 ISTS]. | * Dr. Sonia Dollfus, M.D., Ph.D., CHU de Caen, header of [http://www.ists.cyceron.fr/spip.php?rubrique17 ISTS]. | ||
* Dr. Csaba Pinter, MSc, Queen's University. | * Dr. Csaba Pinter, MSc, Queen's University. | ||
* Dr. Andras Lasso, Ph.D., Queen's University. | * Dr. Andras Lasso, Ph.D., Queen's University. | ||
− | If you use this module, please cite the following article: <ref name="Briend 2018">Briend F. et al., | + | ''If you use this module, please cite the following article: <ref name="Briend 2018">Briend F. et al., Repetitive transcranial magnetic stimulation (rTMS) treatment for auditory hallucinations: personalized or standardized targets? Brain Stimulation, submitted</ref>.'' |
__TOC__ | __TOC__ | ||
Line 29: | Line 30: | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|Module Description}} | {{documentation/{{documentation/version}}/module-section|Module Description}} | ||
− | This module calculates geodesic path in 3D structure. Thanks to this geodesic path, this module can draw an EEG 10-20 system, determine the projected scalp | + | This module calculates geodesic path in 3D structure. Thanks to this geodesic path, this module can draw an EEG 10-20 system, determine the projected scalp stimulation site (MRI guided brain stimulation without the use of a neuronavigation System) and correct the rTMS resting motor threshold by correction factor. |
'''Terminology''' | '''Terminology''' | ||
Line 35: | Line 36: | ||
*'''''Shortest path''''' In graph theory, the shortest path problem is the problem of finding a path between two vertices (or nodes) in a graph such that the sum of the weights of its constituent edges is minimized. | *'''''Shortest path''''' In graph theory, the shortest path problem is the problem of finding a path between two vertices (or nodes) in a graph such that the sum of the weights of its constituent edges is minimized. | ||
*'''''10-20 EEG system''''' The International 10-20 system is commonly used for electroencephalogram (EEG) electrode placement and to correlate external skull locations with underlying cortical areas.<ref name="Jasper 1958">Jasper, H. (1958). The ten twenty electrode system of the international federation. Electroencephalography and Clinical Neurophysiology, 10, 371‑375.</ref> | *'''''10-20 EEG system''''' The International 10-20 system is commonly used for electroencephalogram (EEG) electrode placement and to correlate external skull locations with underlying cortical areas.<ref name="Jasper 1958">Jasper, H. (1958). The ten twenty electrode system of the international federation. Electroencephalography and Clinical Neurophysiology, 10, 371‑375.</ref> | ||
+ | |||
+ | <!-- ---------------------------- --> | ||
+ | {{documentation/{{documentation/version}}/module-section|Installation (in progress)}} | ||
+ | # First, open 3D Slicer | ||
+ | # Open the Slicer Extensions from the icon on the menu bar | ||
+ | # Choose "Geodesic Slicer" module from the list of extensions and click "INSTALL" button. | ||
+ | # Once you restart 3D Slicer, the Geodesic Slicer module should show up on the Modules menu (under Informatics->Geodesic Slicer) | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|Use Cases}} | {{documentation/{{documentation/version}}/module-section|Use Cases}} | ||
The overall goal is to allow users to find the shortest paths between nodes in a graph and via the Dijkstra's algorithm to make 10-20 system. This module can be used for: | The overall goal is to allow users to find the shortest paths between nodes in a graph and via the Dijkstra's algorithm to make 10-20 system. This module can be used for: | ||
− | *Stimulation in psychiatry | + | *Stimulation in psychiatry: MRI guided brain stimulation without the use of a neuronavigation system. |
− | *Surgery measurement | + | *Surgery measurement. |
− | *3D printing | + | *3D printing. |
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
Line 51: | Line 59: | ||
A typical straightforward Geodesic Slicer workflow for consists of the following steps: | A typical straightforward Geodesic Slicer workflow for consists of the following steps: | ||
− | # Load a volume.nii. | + | # Load a volume.nii (by Drag & Drop or the Add Data dialogue). |
# Enter in the Geodesic Slicer module using either the toolbar or the Modules menu button. | # Enter in the Geodesic Slicer module using either the toolbar or the Modules menu button. | ||
− | # Press the button "Create a mesh". | + | # Press the button "Create a quick mesh" or "Create a mesh" (with filling holes smoothing, better for the next part but longer). |
#*Wait a moment. | #*Wait a moment. | ||
− | |||
− | |||
#Go to '''Parameters to find the shortest path''' or '''Make 10-20 EEG system electrode''' section. | #Go to '''Parameters to find the shortest path''' or '''Make 10-20 EEG system electrode''' section. | ||
Line 63: | Line 69: | ||
# Source points: The list of fiducial points on the curve, since the "Create-and-place Fiducial" button (in green in the figure above). | # Source points: The list of fiducial points on the curve, since the "Create-and-place Fiducial" button (in green in the figure above). | ||
− | # Input STL model: The model you use (after "use this mesh", the | + | # Input STL model: The model you use (after "use this mesh", the T1.stl created). |
#* Find the shortest path: Calculate in centimeter the geodesic (shortest) path via the Dijkstra's algorithm. | #* Find the shortest path: Calculate in centimeter the geodesic (shortest) path via the Dijkstra's algorithm. | ||
#* Draw the shortest path: Draw the Dijkstra's algorithm shortest path. | #* Draw the shortest path: Draw the Dijkstra's algorithm shortest path. | ||
Line 69: | Line 75: | ||
====10-20 system electrode==== | ====10-20 system electrode==== | ||
− | Run the Dijkstra's algorithm to make the 10-20 system electrode | + | *Run the Dijkstra's algorithm to '''make the 10-20 system electrode'''. |
[[File:4 landmarks.png|thumb|right|Four anatomical landmarks are used for the essential positioning of the electrodes: the nasion, the inion, the pre auricular to the left ear and the pre auricular to the right ear. ]] | [[File:4 landmarks.png|thumb|right|Four anatomical landmarks are used for the essential positioning of the electrodes: the nasion, the inion, the pre auricular to the left ear and the pre auricular to the right ear. ]] | ||
− | # | + | # 4 anatomical landmarks: (Sources Points) The list of fiducial points on the curve, since the "Create-and-place Fiducial" button (in green in the figure above). Four anatomical landmarks are used for the essential positioning of the electrodes (in this order!): |
− | #* 1/ | + | #* 1/ The nasion |
− | #* 2/ | + | #* 2/ The inion |
− | #* 3/ | + | #* 3/ The pre auricular to the left ear |
− | #* 4/ | + | #* 4/ The pre auricular to the right ear |
− | # Input STL model: The model you use (after "use this mesh", the | + | # Input STL model: The model you use (after "use this mesh", the T1.stl created). |
# Press the button "Make 10-20 EEG system electrode" to draw the 10-20 EEG system via the Dijkstra's algorithm. | # Press the button "Make 10-20 EEG system electrode" to draw the 10-20 EEG system via the Dijkstra's algorithm. | ||
#* The traditional T3P3 site according to the International 10–20 system of electroencephalogram was identified. | #* The traditional T3P3 site according to the International 10–20 system of electroencephalogram was identified. | ||
− | *Project the stimulation site on the 10-20 system electrode distances and characterize it. | + | *'''Project the stimulation site''' on the 10-20 system electrode distances and characterize it. |
# Stimulation Site placed: Place on the T1-weighted anatomical image the stimulation point that you want since the "Create-and-place Fiducial" button. Once this point given, click on 'Yes'. | # Stimulation Site placed: Place on the T1-weighted anatomical image the stimulation point that you want since the "Create-and-place Fiducial" button. Once this point given, click on 'Yes'. | ||
− | # Press the button "Project the stimulation site" to project the stimulation point on the scalp and find the | + | # Press the button "Project the stimulation site" to project the stimulation point on the scalp and find the 3 nearest electrodes around it. |
#* Nearest electrode 1: The distance in centimeter between the first nearest electrode and the projected stimulation site. | #* Nearest electrode 1: The distance in centimeter between the first nearest electrode and the projected stimulation site. | ||
#* Nearest electrode 2: The distance in centimeter between the second nearest electrode and the projected stimulation site. | #* Nearest electrode 2: The distance in centimeter between the second nearest electrode and the projected stimulation site. | ||
Line 92: | Line 98: | ||
Calculate correction factors to adjust the rTMS dose for the treatment (according to the depth of the stimulation site). | Calculate correction factors to adjust the rTMS dose for the treatment (according to the depth of the stimulation site). | ||
− | # M1 Point Placed: Place on the T1-weighted anatomical image a point targeting the human motor cortex since the "Create-and-place Fiducial" button. Once this point given, click on 'Yes'. | + | [[File:M1.png|thumb|Localization of the motor hand area via a knob on the precentral gyrus]] |
+ | |||
+ | # M1 Point Placed: Place on the T1-weighted anatomical image a point targeting the human [https://en.wikipedia.org/wiki/Motor_cortex|motor motor cortex] since the "Create-and-place Fiducial" button. Once this point given, click on 'Yes'. Help via the [https://pdfs.semanticscholar.org/ba38/045e9f01ec4d128c5fbe5a46dc209fccaac4.pdf Yousry's method]. | ||
# Set the stimulation intensity of the resting motor threshold. | # Set the stimulation intensity of the resting motor threshold. | ||
# Press the button "Correct the motor threshold" to correct the unadjusted motor threshold (rMT) in % stimulator output. | # Press the button "Correct the motor threshold" to correct the unadjusted motor threshold (rMT) in % stimulator output. | ||
− | #* Two adjusted motor threshold (AdjMT%) in % stimulator output are given | + | #* Two adjusted motor threshold (AdjMT%) in % stimulator output are given where SCDx is the scalp-to-cortex distance between the scalp and and the Stimulation Site, SCDm is the scalp-to-cortex distance between the scalp and M1. |
− | #* 1/ The first according to Stokes et al. Clin Neurophysiol 2007 <ref name="Stokes 2007">Stokes, M. G., Chambers, C. D., Gould, I. C., English, T., McNaught, E., McDonald, O., & Mattingley, J. B. (2007). Distance-adjusted motor threshold for transcranial magnetic stimulation. Clinical Neurophysiology, 118(7), 1617‑1625.</ref> , where [AdjMT% = 2,7 | + | #* 1/ The first according to Stokes et al. Clin Neurophysiol 2007 <ref name="Stokes 2007">Stokes, M. G., Chambers, C. D., Gould, I. C., English, T., McNaught, E., McDonald, O., & Mattingley, J. B. (2007). Distance-adjusted motor threshold for transcranial magnetic stimulation. Clinical Neurophysiology, 118(7), 1617‑1625.</ref> , where [AdjMT% = 2,7*(SCDx - SCDm) + rMT] |
− | #* 2/ The second according to Hoffman et al. Biol Psychiatry 2013 <ref name="Hoffman 2013">Hoffman, R. E., Wu, K., Pittman, B., Cahill, J. D., Hawkins, K. A., Fernandez, T., & Hannestad, J. (2013). Transcranial magnetic stimulation of Wernicke’s and Right homologous sites to curtail « voices »: a randomized trial. Biological Psychiatry, 73(10), 1008‑1014. </ref> , where [AdjMT% | + | #* 2/ The second according to Hoffman et al. Biol Psychiatry 2013 <ref name="Hoffman 2013">Hoffman, R. E., Wu, K., Pittman, B., Cahill, J. D., Hawkins, K. A., Fernandez, T., & Hannestad, J. (2013). Transcranial magnetic stimulation of Wernicke’s and Right homologous sites to curtail « voices »: a randomized trial. Biological Psychiatry, 73(10), 1008‑1014. </ref> , where [AdjMT% = 0.90*rMT*e0.036*(SCDx-SCDm)] |
<!-- ---------------------------- --> | <!-- ---------------------------- --> |
Latest revision as of 18:12, 7 January 2019
Home < Documentation < 4.8 < Modules < GeodesicSlicer
For the latest Slicer documentation, visit the read-the-docs. |
Introduction and Acknowledgements
|
The module has been developed based on ideas and feedbacks from the community. We would like to especially thank:
- Dr. Olivier Etard, M.D., Ph.D., CHU de Caen.
- Dr. Clément Nathou, M.D., Ph.D., CHU de Caen.
- Dr. Nicolas Delcroix, Ph.D., UMS 3408.
- Dr. Sonia Dollfus, M.D., Ph.D., CHU de Caen, header of ISTS.
- Dr. Csaba Pinter, MSc, Queen's University.
- Dr. Andras Lasso, Ph.D., Queen's University.
If you use this module, please cite the following article: [1].
Contents
Module Description
This module calculates geodesic path in 3D structure. Thanks to this geodesic path, this module can draw an EEG 10-20 system, determine the projected scalp stimulation site (MRI guided brain stimulation without the use of a neuronavigation System) and correct the rTMS resting motor threshold by correction factor.
Terminology
- Mesh A mesh or polygon mesh is a collection of vertices, edges and faces that defines the shape of a polyhedral object in 3D computer graphics and solid modeling.
- Shortest path In graph theory, the shortest path problem is the problem of finding a path between two vertices (or nodes) in a graph such that the sum of the weights of its constituent edges is minimized.
- 10-20 EEG system The International 10-20 system is commonly used for electroencephalogram (EEG) electrode placement and to correlate external skull locations with underlying cortical areas.[2]
Installation (in progress)
- First, open 3D Slicer
- Open the Slicer Extensions from the icon on the menu bar
- Choose "Geodesic Slicer" module from the list of extensions and click "INSTALL" button.
- Once you restart 3D Slicer, the Geodesic Slicer module should show up on the Modules menu (under Informatics->Geodesic Slicer)
Use Cases
The overall goal is to allow users to find the shortest paths between nodes in a graph and via the Dijkstra's algorithm to make 10-20 system. This module can be used for:
- Stimulation in psychiatry: MRI guided brain stimulation without the use of a neuronavigation system.
- Surgery measurement.
- 3D printing.
Panels and their use
Create a mesh
A typical straightforward Geodesic Slicer workflow for consists of the following steps:
- Load a volume.nii (by Drag & Drop or the Add Data dialogue).
- Enter in the Geodesic Slicer module using either the toolbar or the Modules menu button.
- Press the button "Create a quick mesh" or "Create a mesh" (with filling holes smoothing, better for the next part but longer).
- Wait a moment.
- Go to Parameters to find the shortest path or Make 10-20 EEG system electrode section.
Parameters to find the shortest path
- Source points: The list of fiducial points on the curve, since the "Create-and-place Fiducial" button (in green in the figure above).
- Input STL model: The model you use (after "use this mesh", the T1.stl created).
- Find the shortest path: Calculate in centimeter the geodesic (shortest) path via the Dijkstra's algorithm.
- Draw the shortest path: Draw the Dijkstra's algorithm shortest path.
- Length (cm): The length of the current curve is shown in centimeter.
10-20 system electrode
- Run the Dijkstra's algorithm to make the 10-20 system electrode.
- 4 anatomical landmarks: (Sources Points) The list of fiducial points on the curve, since the "Create-and-place Fiducial" button (in green in the figure above). Four anatomical landmarks are used for the essential positioning of the electrodes (in this order!):
- 1/ The nasion
- 2/ The inion
- 3/ The pre auricular to the left ear
- 4/ The pre auricular to the right ear
- Input STL model: The model you use (after "use this mesh", the T1.stl created).
- Press the button "Make 10-20 EEG system electrode" to draw the 10-20 EEG system via the Dijkstra's algorithm.
- The traditional T3P3 site according to the International 10–20 system of electroencephalogram was identified.
- Project the stimulation site on the 10-20 system electrode distances and characterize it.
- Stimulation Site placed: Place on the T1-weighted anatomical image the stimulation point that you want since the "Create-and-place Fiducial" button. Once this point given, click on 'Yes'.
- Press the button "Project the stimulation site" to project the stimulation point on the scalp and find the 3 nearest electrodes around it.
- Nearest electrode 1: The distance in centimeter between the first nearest electrode and the projected stimulation site.
- Nearest electrode 2: The distance in centimeter between the second nearest electrode and the projected stimulation site.
- Nearest electrode 3: The distance in centimeter between the third nearest electrode and the projected stimulation site.
rTMS resting motor threshold- Correction factor
Calculate correction factors to adjust the rTMS dose for the treatment (according to the depth of the stimulation site).
- M1 Point Placed: Place on the T1-weighted anatomical image a point targeting the human motor cortex since the "Create-and-place Fiducial" button. Once this point given, click on 'Yes'. Help via the Yousry's method.
- Set the stimulation intensity of the resting motor threshold.
- Press the button "Correct the motor threshold" to correct the unadjusted motor threshold (rMT) in % stimulator output.
- Two adjusted motor threshold (AdjMT%) in % stimulator output are given where SCDx is the scalp-to-cortex distance between the scalp and and the Stimulation Site, SCDm is the scalp-to-cortex distance between the scalp and M1.
- 1/ The first according to Stokes et al. Clin Neurophysiol 2007 [3] , where [AdjMT% = 2,7*(SCDx - SCDm) + rMT]
- 2/ The second according to Hoffman et al. Biol Psychiatry 2013 [4] , where [AdjMT% = 0.90*rMT*e0.036*(SCDx-SCDm)]
Information for Developers
The code is available at Github.
References
- ↑ Briend F. et al., Repetitive transcranial magnetic stimulation (rTMS) treatment for auditory hallucinations: personalized or standardized targets? Brain Stimulation, submitted
- ↑ Jasper, H. (1958). The ten twenty electrode system of the international federation. Electroencephalography and Clinical Neurophysiology, 10, 371‑375.
- ↑ Stokes, M. G., Chambers, C. D., Gould, I. C., English, T., McNaught, E., McDonald, O., & Mattingley, J. B. (2007). Distance-adjusted motor threshold for transcranial magnetic stimulation. Clinical Neurophysiology, 118(7), 1617‑1625.
- ↑ Hoffman, R. E., Wu, K., Pittman, B., Cahill, J. D., Hawkins, K. A., Fernandez, T., & Hannestad, J. (2013). Transcranial magnetic stimulation of Wernicke’s and Right homologous sites to curtail « voices »: a randomized trial. Biological Psychiatry, 73(10), 1008‑1014.