− | Acknowledgments:
| |
− | This work is part of the National Alliance for Medical Image Computing (NA-MIC), funded by the National Institutes of Health through the NIH Roadmap for Medical Research.<br>
| |
− | Implementation of the pharmacokinetics modeling was contributed by Yingxuan Zhu and Jim Miller from GE Research.<br>
| |
− | Author: Yingxuan Zhu, Jim Miller ({{collaborator|name|ge}})<br>
| |
− | Contact: Yingxuan Zhu, <email>zhuyi@ge.com</email><br>
| |
− | {{documentation/{{documentation/version}}/module-introduction-row}}
| |
− | {{documentation/{{documentation/version}}/module-introduction-logo-gallery
| |
− | |{{collaborator|logo|ge}}|{{collaborator|longname|ge}}
| |
− | |{{collaborator|logo|namic}}|{{collaborator|longname|namic}}
| |
− | }}
| |
− | | |
− | {{documentation/{{documentation/version}}/module-introduction-end}}
| |
− | | |
− | <!-- ---------------------------- -->
| |
− | {{documentation/{{documentation/version}}/module-section|Module Description}}
| |
− | {|
| |
− | |
| |
− | PkModeling (Pharmacokinetics Modeling) calculates quantitative parameters from Dynamic Contrast Enhanced DCE-MRI images. This module performs two operations:
| |
− | # Converts signal intensities to concentration values. The concentration values are used to calculate quantitative parameters.
| |
− | # Calculates quantitative parameters from concentration values. These parameters include:
| |
− | ;Ktrans: Volume transfer constant between blood plasma and EES (extracellular-extravascular space) at each voxel
| |
− | ;Ve: Fractional volume for extracellular space at each voxel
| |
− | ;MaxSlope: Maximum slope in the time series curve of each voxel
| |
− | ;AUC: Area under the curve of each voxel, measured from bolus arrival time to the end time of interval, normalized by the AUC of the AIF
| |
− | | |
− | |}
| |
− | | |
− | <!-- ---------------------------- -->
| |
− | {{documentation/{{documentation/version}}/module-section|Use Cases}}
| |
− | {|
| |
− | |}
| |
− | | |
− | <!-- ---------------------------- -->
| |
− | {{documentation/{{documentation/version}}/module-section|Tutorials}}
| |
− | | |
− | <!-- ---------------------------- -->
| |
− | {{documentation/{{documentation/version}}/module-section|Panels and their use}}
| |
− | | |
− | {|
| |
− | |[[Image:PkModelingUI061912.png|thumb|340px|PkModeling]]
| |
− | |
| |
− | * '''IO'''
| |
− | ** '''Input:''' 4D DCE-MRI data; 3D mask showing the location of the arterial input function.
| |
− | ** '''Output:''' 4 volumes showing the maps of quantitative parameters: ktrans, ve, maximum slope, and area under the curve (AUC).
| |
− | * '''Parameters'''
| |
− | ** '''PkModeling''':
| |
− | *** T1 Blood Value
| |
− | *** T1 Tissue Value
| |
− | *** Relaxivity Value
| |
− | *** Hematocrit Value. Volume percentage of red blood cells in blood.
| |
− | *** AUC Time Interval Value: Time interval for AUC calculation
| |
− | ** '''Acquisition''':
| |
− | *** TR Value: Repetition time,
| |
− | *** TE Value: Echo time,
| |
− | *** FA Value: Flip angle,
| |
− | *** Time Axis: Time series.
| |
− | | |
− | |}
| |
− | | |
− | <!-- ---------------------------- -->
| |
− | {{documentation/{{documentation/version}}/module-section|Similar Modules}}
| |
− | * [[Documentation/{{documentation/version}}/Modules/MultiVolumeExplorer|MultiVolumeExplorer]]
| |
− | * [[Documentation/{{documentation/version}}/Modules/MultiVolumeImporter|MultiVolumeImporter]]
| |
− | | |
− | <!-- ---------------------------- -->
| |
− | {{documentation/{{documentation/version}}/module-section|References}}
| |
− | * Knopp MV, Giesel FL, Marcos H et al: Dynamic contrast-enhanced magnetic resonance imaging in oncology. Top Magn Reson Imaging, 2001; 12:301-308.
| |
− | * Rijpkema M, Kaanders JHAM, Joosten FBM et al: Method for quantitative mapping of dynamic MRI contrast agent uptake in human tumors. J Magn Reson Imaging 2001; 14:457-463.
| |
− | | |
− | <!-- ---------------------------- -->
| |