Difference between revisions of "Documentation/Nightly/Extensions/Igyne"

From Slicer Wiki
Jump to: navigation, search
(Created page with '<!-- ---------------------------- --> {{documentation/{{documentation/version}}/module-header}} <!-- ---------------------------- --> <!-- ---------------------------- --> {{doc…')
 
(Prepend documentation/versioncheck template. See http://na-mic.org/Mantis/view.php?id=2887)
 
(24 intermediate revisions by 3 users not shown)
Line 1: Line 1:
<!-- ---------------------------- -->
+
<noinclude>{{documentation/versioncheck}}</noinclude>
{{documentation/{{documentation/version}}/module-header}}
 
<!-- ---------------------------- -->
 
  
<!-- ---------------------------- -->
+
Moved to http://www.slicer.org/slicerWiki/index.php/Documentation/Nightly/Extensions/iGyne
{{documentation/{{documentation/version}}/module-section|Introduction and Acknowledgements}}
 
Author: Xiaojun Chen<br>
 
Contributors: Xiaojun Chen,Jan Egger,Tina Kapur,Akila N. Viswanathan(BWH), Steve Pieper(Isomics)<br>
 
Contact: Xiaojun Chen, <email>xiaojun@bwh.harvard.edu</email><br>
 
Website: https://github.com/xjchen/igyne<br>
 
License: [http://www.slicer.org/pages/LicenseText Slicer license]
 
 
 
 
 
 
 
<!-- ---------------------------- -->
 
{{documentation/{{documentation/version}}/extension-section|Extension Description}}
 
Igyne is an open source software for MR-Guided Interstitial Gynecologic Brachytherapy. It enables on-time processing of the intra-operative MRI data via a DICOM connection to the scanner followed by a multi-stage registration of CAD models of the template and the obturator to the patient images. This allows the virtual placement of interstitial needles during the intervention to assist the physician positioning decision.Software features include:
 
 
 
*Loading of Applicator CAD models and MR images
 
*Demons method for deformable image registration (GPU accelerated)
 
*ITK-based algorithms for translation, rigid, affine, demons, and B-spline registration
 
*Pipelined, multi-stage registration framework with seamless conversion between most algorithms and transform types
 
*Landmark-based deformable registration using thin-plate splines for global registration
 
*Landmark-based deformable registration using radial basis functions for local corrections
 
*Broad support for 3D image file formats (using ITK), including DICOM, Nifti, NRRD, MetaImage, and Analyze
 
*DICOM and DICOM-RT import and export
 
*XiO import and export
 
 
 
<!-- ---------------------------- -->
 
{{documentation/{{documentation/version}}/extension-section|Modules}}
 
*[[Documentation/{{documentation/version}}/Modules/PlmBSplineDeformableRegistration|Plastimatch Automatic deformable image registration]]
 
*[[Documentation/{{documentation/version}}/Modules/PlmDICOMRTImport|Plastimatch DICOM-RT import]]
 
*[[Documentation/{{documentation/version}}/Modules/PlmDICOMRTExport|Plastimatch DICOM-RT export]]
 
*[[Documentation/{{documentation/version}}/Modules/PlmDoseComparison|Plastimatch Dose Comparison]]
 
*[[Documentation/{{documentation/version}}/Modules/PlmDoseVolumeHistogram|Plastimatch Dose Volume Histogram]]
 
*[[Documentation/{{documentation/version}}/Modules/PlmLANDWARP|Plastimatch LANDWARP Landmark]]
 
*[[Documentation/{{documentation/version}}/Modules/PlmSyntheticImageGeneration|Plastimatch Synthetic Image Generation]]
 
*[[Documentation/{{documentation/version}}/Modules/PlmThreshBox|Plastimatch Threshold in a box]]
 
*[[Documentation/{{documentation/version}}/Modules/PlmXFORMWARP|Plastimatch XFORMWARP]]
 
 
 
<!-- ---------------------------- -->
 
{{documentation/{{documentation/version}}/extension-section|Use Cases}}
 
[http://plastimatch.org/data_sources.html Sample data] to use with modules.
 
<gallery widths="200px" perrow="4">
 
Image:plastimatch_dicomrt_ss.png|DICOM-RT Structure Set
 
Image:plastimatch_dicomrt_dose.png|DICOM-RT Dose
 
Image:plastimatch_image_1.png|Before Registration
 
Image:plastimatch_image_2.png|After Registration
 
Image:before_reg.png|Before Registration
 
Image:after_reg.png|After Registration
 
</gallery>
 
 
 
<!-- ---------------------------- -->
 
{{documentation/{{documentation/version}}/extension-section|Tutorials}}
 
 
 
<gallery widths="200px" perrow="4">
 
Image:plastimatch_tutorial_ppt.png|[http://forge.abcd.harvard.edu/gf/download/frsrelease/110/1023/3D_Slicer_Plastimatch_Registration_Tutorial.ppt Download tutorial]
 
Image:plastimatch_tutorial_data.png|[http://forge.abcd.harvard.edu/gf/download/frsrelease/85/1004/rider-lung-images.tar.gz Download tutorial data]
 
Image:plastimatch_dicomrt_tutorial_ppt.png|[http://forge.abcd.harvard.edu/gf/download/frsrelease/110/1568/3D_Slicer_Plastimatch_DICOM_RT_Tutorial_2010_12_28.pdf Download tutorial (PDF)]
 
Image:plastimatch_dicomrt_ss.png|[http://forge.abcd.harvard.edu/gf/download/frsrelease/85/934/chest-phantom-dicomrt-xio-4.33.02.tar.gz (Download tutorial data)]
 
Image:3D_Slicer_Plastimatch_Landmark_Registration_Tutorial.png|[http://forge.abcd.harvard.edu/gf/download/frsrelease/110/1622/3D_Slicer_Plastimatch_Landmark_Registration_Tutorial.ppt Download tutorial]
 
Image:fixed.png|[http://forge.abcd.harvard.edu/gf/download/frsrelease/85/1619/synthetic_img.zip Download tutorial data]
 
</gallery>
 
 
 
<!-- ---------------------------- -->
 
{{documentation/{{documentation/version}}/extension-section|Similar Extensions}}
 
N/A
 
 
 
<!-- ---------------------------- -->
 
{{documentation/{{documentation/version}}/extension-section|References}}
 
* G Sharp, N Kandasamy, H Singh, M Folkert, "GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration," Physics in Medicine and Biology, 52(19), pp 5771-83, 2007.
 
* V Boldea, G Sharp, SB Jiang, D Sarrut, "4D-CT lung motion estimation with deformable registration: Quantification of motion nonlinearity and hysteresis," Medical Physics, 33(3), pp 1008-18, 2008.
 
* Z Wu, E Rietzel, V Boldea, D Sarrut, G Sharp, "Evaluation of deformable registration of patient lung 4DCT with sub-anatomical region segmentations," Medical Physics, 35(2), pp 775-81, 2008.
 
* G Sharp et al. "Plastimatch - An open source software suite for radiotherapy image processing," Proceedings of the XVIth International Conference on the use of Computers in Radiotherapy, May, 2010.
 
* N. Shusharina, G. Sharp "Landmark-based image registration with analytic regularization", IEEE Trans. Med. Imag., submitted, 2011.
 
 
 
<!-- ---------------------------- -->
 
{{documentation/{{documentation/version}}/extension-section|Information for Developers}}
 
{{documentation/{{documentation/version}}/extension-developerinfo}}
 
 
 
<!-- ---------------------------- -->
 
{{documentation/{{documentation/version}}/extension-footer}}
 
<!-- ---------------------------- -->
 

Latest revision as of 07:50, 14 June 2013

Home < Documentation < Nightly < Extensions < Igyne