Difference between revisions of "Documentation/4.1/Modules/PkModeling"
From Slicer Wiki
(Prepend documentation/versioncheck template. See http://na-mic.org/Mantis/view.php?id=2887) |
|||
(3 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
+ | <noinclude>{{documentation/versioncheck}}</noinclude> | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-header}} | {{documentation/{{documentation/version}}/module-header}} | ||
Line 47: | Line 48: | ||
{| | {| | ||
− | |[[Image: | + | |[[Image:PkModelingUI061912.png|thumb|340px|PkModeling]] |
| | | | ||
* '''IO''' | * '''IO''' | ||
Line 57: | Line 58: | ||
*** T1 Tissue Value | *** T1 Tissue Value | ||
*** Relaxivity Value | *** Relaxivity Value | ||
− | *** Hematocrit Value | + | *** Hematocrit Value. Volume percentage of red blood cells in blood. |
*** AUC Time Interval Value: Time interval for AUC calculation | *** AUC Time Interval Value: Time interval for AUC calculation | ||
** '''Acquisition''': | ** '''Acquisition''': | ||
Line 69: | Line 70: | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|Similar Modules}} | {{documentation/{{documentation/version}}/module-section|Similar Modules}} | ||
− | * [[Documentation/ | + | * [[Documentation/{{documentation/version}}/Modules/MultiVolumeExplorer|MultiVolumeExplorer]] |
− | * [[Documentation/ | + | * [[Documentation/{{documentation/version}}/Modules/MultiVolumeImporter|MultiVolumeImporter]] |
<!-- ---------------------------- --> | <!-- ---------------------------- --> |
Latest revision as of 07:28, 14 June 2013
Home < Documentation < 4.1 < Modules < PkModeling
For the latest Slicer documentation, visit the read-the-docs. |
Introduction and Acknowledgements
Extension: PkModeling | |||||
|
Module Description
PkModeling (Pharmacokinetics Modeling) calculates quantitative parameters from Dynamic Contrast Enhanced DCE-MRI images. This module performs two operations:
|
Use Cases
Tutorials
Panels and their use
|
Similar Modules
References
- Knopp MV, Giesel FL, Marcos H et al: Dynamic contrast-enhanced magnetic resonance imaging in oncology. Top Magn Reson Imaging, 2001; 12:301-308.
- Rijpkema M, Kaanders JHAM, Joosten FBM et al: Method for quantitative mapping of dynamic MRI contrast agent uptake in human tumors. J Magn Reson Imaging 2001; 14:457-463.
Information for Developers
Section under construction. |