Difference between revisions of "Documentation/4.0/Modules/ChangeTracker"
(Created page with '<!-- ---------------------------- --> {{documentation/{{documentation/version}}/module-header}} <!-- ---------------------------- --> <!-- ---------------------------- --> {{doc…') |
(Prepend documentation/versioncheck template. See http://na-mic.org/Mantis/view.php?id=2887) |
||
(14 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
+ | <noinclude>{{documentation/versioncheck}}</noinclude> | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-header}} | {{documentation/{{documentation/version}}/module-header}} | ||
Line 7: | Line 8: | ||
{{documentation/{{documentation/version}}/module-introduction-start|{{documentation/modulename}}}} | {{documentation/{{documentation/version}}/module-introduction-start|{{documentation/modulename}}}} | ||
{{documentation/{{documentation/version}}/module-introduction-row}} | {{documentation/{{documentation/version}}/module-introduction-row}} | ||
− | This work is supported by NA-MIC, NAC, NCIGT, and the Slicer Community. This work is partially supported by NIH U01 CA151261<br> | + | This work is supported by NA-MIC, NAC, NCIGT, and the Slicer Community. This work is partially supported by Brain Science Foundation and NIH U01 CA151261.<br> |
− | Author: Andrey Fedorov, Ron Kikinis, SPL <br> | + | Author: Andrey Fedorov, Kilian Pohl, Peter Black, Ron Kikinis, SPL <br> |
Contact: Andrey Fedorov <email>fedorov@bwh.harvard.edu</email> <br> | Contact: Andrey Fedorov <email>fedorov@bwh.harvard.edu</email> <br> | ||
{{documentation/{{documentation/version}}/module-introduction-row}} | {{documentation/{{documentation/version}}/module-introduction-row}} | ||
{{documentation/{{documentation/version}}/module-introduction-logo-gallery | {{documentation/{{documentation/version}}/module-introduction-logo-gallery | ||
− | | | + | |{{collaborator|logo|namic}}|{{collaborator|longname|namic}} |
+ | |{{collaborator|logo|bsf}}|{{collaborator|longname|bsf}} | ||
+ | |{{collaborator|logo|ncigt}}|{{collaborator|longname|ncigt}} | ||
+ | |{{collaborator|logo|spl}}|{{collaborator|longname|spl}} | ||
}} | }} | ||
{{documentation/{{documentation/version}}/module-introduction-end}} | {{documentation/{{documentation/version}}/module-introduction-end}} | ||
− | |||
− | |||
− | |||
− | |||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|Module Description}} | {{documentation/{{documentation/version}}/module-section|Module Description}} | ||
+ | |||
+ | {| | ||
+ | | | ||
ChangeTracker is a software tool for quantification of the subtle changes in pathology. The module provides a workflow pipeline that combines user input with the medical data. As a result we provide quantitative volumetric measurements of growth/shrinkage together with the volume rendering of the tumor and color-coded visualization of the tumor growth/shrinkage. | ChangeTracker is a software tool for quantification of the subtle changes in pathology. The module provides a workflow pipeline that combines user input with the medical data. As a result we provide quantitative volumetric measurements of growth/shrinkage together with the volume rendering of the tumor and color-coded visualization of the tumor growth/shrinkage. | ||
− | ChangeTracker is not yet a generic tool for detecting small changes. It has been tuned specifically for meningioma growth analysis. Specifically, the assumptions made by ChangeTracker are | + | |
− | the analyzed images are roughly aligned | + | ChangeTracker is not yet a generic tool for detecting small changes. It has been tuned specifically for meningioma growth analysis. Specifically, the assumptions made by ChangeTracker are |
− | the pathology area is characterized by bright image intensities (contrast-enhanced meningioma MRI) | + | * the analyzed images are roughly aligned |
− | images have similar, close to isotropic, spacing | + | * the pathology area is characterized by bright image intensities (contrast-enhanced meningioma MRI) |
− | the change in pathology between the consequtive scans is small in relation to the total pathology volume | + | * images have similar, close to isotropic, spacing |
+ | * the change in pathology between the consequtive scans is small in relation to the total pathology volume. | ||
+ | |||
If you want to apply ChangeTracker on non-meningioma data, please let us know. The algorithm is likely to require tuning of the parameters for registration and other processing steps. | If you want to apply ChangeTracker on non-meningioma data, please let us know. The algorithm is likely to require tuning of the parameters for registration and other processing steps. | ||
+ | |||
+ | |[[Image:Slicer4_ChangeTracker_Ad.png|thumb|450px|ChangeTracker processing results visualization]] | ||
+ | |} | ||
+ | |||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
Line 38: | Line 47: | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|Tutorials}} | {{documentation/{{documentation/version}}/module-section|Tutorials}} | ||
− | + | ||
+ | The test data can be downloaded automatically by pushing the "Load test data" in the panel of the first step (you will need the internet connection). | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|Panels and their use}} | {{documentation/{{documentation/version}}/module-section|Panels and their use}} | ||
− | + | ChangeTracker is organized as a workflow that consists of the following steps: | |
− | {| | + | * '''Step 1: Define input scans''' |
− | | | + | |
− | * | + | {| |
− | + | |Use drop-down controls to choose the two scans where you would like to measure pathology development. Currently, we support analysis of the images that correspond to two time points. | |
− | * | + | |
− | * | + | |[[Image:Slicer4_ChangeTracker_Step1.png|thumb|450px|Step 1: Scan selection]] |
− | + | |} | |
− | + | ||
− | + | * '''Step 2: Define volume of interest''' | |
− | + | ||
− | + | {| | |
− | * | + | |This step of wizard includes the following user controls to facilitate Volume of Interest (VOI) selection: |
− | | | + | * "Hide/show render" button: used to control visibility of volume rendering for the selected region |
− | [[Image: | + | * "ROI Widget Controls: RAS Space" frame: contains sliders to initialize VOI in RAS (physical) space |
− | | | + | "ROI Widget" refers to the three-dimensional selection box that appears in the 3d slice view once you begin to select VOI. You can define VOI by adjusting the colored handles of the ROI widget in the slice viewer or 3d viewer. |
− | | | + | |
− | * | + | |[[Image:Slicer4_ChangeTracker_Step2.png|thumb|450px|Step 2: ROI Widget controls in wizard GUI]] |
− | + | |} | |
− | + | ||
− | * | + | |
− | + | * '''Step 3: Segment the analyzed structure''' | |
− | + | ||
− | + | {| | |
− | * | + | |Use threshold control slider to find the intensity that most closely approximates tumor volume. Thresholded volume is rendered interactively in the 3D viewer as you are adjusting the threshold value, and is also visualized as semi-transparent label in the image slice viewers. |
− | * | + | |
− | * | + | Note, that currently ChangeTracker expects that the tissue you monitor is hyperintensive on the image. |
− | | | + | |
− | [[Image: | + | In the cases when threshold is not effective in segmenting the structure of interest, '''Advanced''' tab allows to prescribe the segmentation label image directly, instead of using threshold. (''this feature is currently disabled, under development'') |
+ | |||
+ | |[[Image:Slicer4_ChangeTracker_Step3.png|thumb|450px|Step 3: ChangeTracker ROI segmentation]] | ||
+ | |} | ||
+ | |||
+ | * '''Step 4: ROI Analysis''' | ||
+ | |||
+ | {| | ||
+ | |Choose the metric(s) you would like to use. ChangeTracker provides an extensible framework for developing and incorporating change quantification metrics into the workflow (see Information for Developers section). The metrics currently available are the following (follow the links for details and documentation): | ||
+ | * [[Documentation/4.0/Modules/IntensityDifferenceMetric | Intensity Difference Metric]] is based on intensity difference between the two ROIs | ||
+ | |||
+ | In some cases, the registration procedure that ChangeTracker is using may not be robust enough to align your data. If this happens and the baseline and followup ROIs are not aligned after this step, you can use the '''Advanced''' tab to register your data, and place followup volume under the transform. ChangeTracker will use the prescribed transform and will skip registration step. | ||
+ | |||
+ | |[[Image:Slicer4_ChangeTracker_Step4.png|thumb|450px|Step 4: ROI Analysis]] | ||
+ | |} | ||
+ | |||
+ | * '''Step 5: ROI Analysis Results''' | ||
+ | |||
+ | {| | ||
+ | |Results are reported as the change in tumor volume, separately for growth and shrinkage component. The quantitative results are reported in voxels, mL and percentage relative the the volume of the structure segmented in the baseline scan. | ||
+ | |||
+ | The visualization of the analysis results includes the following components upon the completion of analysis: | ||
+ | * Red slice view: resampled VOI for the second of the analyzed time-points | ||
+ | * 3d slice viewer: color-coded results of the change analysis. Red color corresponds to the estimated growth regions, Green corresponds to estimated shrinkage. | ||
+ | * Compare view: first row contains the resampled ROI corresponding to the first time-point as foreground, with the growth analysis results in the background. The second row contains resampled ROI corresponding to the second time-point. | ||
+ | |||
+ | |[[Image:Slicer4_ChangeTracker_Step5.png|thumb|450px|Step 5: ROI Analysis Results]] | ||
|} | |} | ||
+ | |||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|Similar Modules}} | {{documentation/{{documentation/version}}/module-section|Similar Modules}} | ||
− | + | N/A | |
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|References}} | {{documentation/{{documentation/version}}/module-section|References}} | ||
− | + | * Konukoglu, E., Wells, W. M., Novellas, S., Ayache, N., Kikinis, R., Black, P. M., & Pohl, K. M. (2008). Monitoring slowly evolving tumors. 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro (pp. 812-815). IEEE. doi:10.1109/ISBI.2008.4541120 [http://www.spl.harvard.edu/publications/item/view/1958 URL] | |
− | + | * Pohl, K. M., Konukoglu, E., Novellas, S., Ayache, N., Fedorov, A., Talos, I.-F., Golby, A., et al. (2011). A new metric for detecting change in slowly evolving brain tumors: validation in meningioma patients. Neurosurgery, 68(1 Suppl Operative), 225-33. doi:10.1227/NEU.0b013e31820783d5 [http://www.spl.harvard.edu/publications/item/view/1958 URL] | |
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|Information for Developers}} | {{documentation/{{documentation/version}}/module-section|Information for Developers}} | ||
− | {{documentation/{{documentation/version}}/module-developerinfo | + | {{documentation/{{documentation/version}}/module-developerinfo}} |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
− | {{documentation/{{documentation/version}}/module-footer | + | {{documentation/{{documentation/version}}/module-footer}} |
<!-- ---------------------------- --> | <!-- ---------------------------- --> |
Latest revision as of 07:36, 14 June 2013
Home < Documentation < 4.0 < Modules < ChangeTracker
For the latest Slicer documentation, visit the read-the-docs. |
Introduction and Acknowledgements
This work is supported by NA-MIC, NAC, NCIGT, and the Slicer Community. This work is partially supported by Brain Science Foundation and NIH U01 CA151261. | |||||||||
|
Module Description
ChangeTracker is a software tool for quantification of the subtle changes in pathology. The module provides a workflow pipeline that combines user input with the medical data. As a result we provide quantitative volumetric measurements of growth/shrinkage together with the volume rendering of the tumor and color-coded visualization of the tumor growth/shrinkage. ChangeTracker is not yet a generic tool for detecting small changes. It has been tuned specifically for meningioma growth analysis. Specifically, the assumptions made by ChangeTracker are
If you want to apply ChangeTracker on non-meningioma data, please let us know. The algorithm is likely to require tuning of the parameters for registration and other processing steps. |
Use Cases
Most frequently used for these scenarios:
- Quantification of small changes in meningioma tumor volume from post-contrast MRI
Tutorials
The test data can be downloaded automatically by pushing the "Load test data" in the panel of the first step (you will need the internet connection).
Panels and their use
ChangeTracker is organized as a workflow that consists of the following steps:
- Step 1: Define input scans
Use drop-down controls to choose the two scans where you would like to measure pathology development. Currently, we support analysis of the images that correspond to two time points. |
- Step 2: Define volume of interest
This step of wizard includes the following user controls to facilitate Volume of Interest (VOI) selection:
"ROI Widget" refers to the three-dimensional selection box that appears in the 3d slice view once you begin to select VOI. You can define VOI by adjusting the colored handles of the ROI widget in the slice viewer or 3d viewer. |
- Step 3: Segment the analyzed structure
Use threshold control slider to find the intensity that most closely approximates tumor volume. Thresholded volume is rendered interactively in the 3D viewer as you are adjusting the threshold value, and is also visualized as semi-transparent label in the image slice viewers.
Note, that currently ChangeTracker expects that the tissue you monitor is hyperintensive on the image. In the cases when threshold is not effective in segmenting the structure of interest, Advanced tab allows to prescribe the segmentation label image directly, instead of using threshold. (this feature is currently disabled, under development) |
- Step 4: ROI Analysis
Choose the metric(s) you would like to use. ChangeTracker provides an extensible framework for developing and incorporating change quantification metrics into the workflow (see Information for Developers section). The metrics currently available are the following (follow the links for details and documentation):
In some cases, the registration procedure that ChangeTracker is using may not be robust enough to align your data. If this happens and the baseline and followup ROIs are not aligned after this step, you can use the Advanced tab to register your data, and place followup volume under the transform. ChangeTracker will use the prescribed transform and will skip registration step. |
- Step 5: ROI Analysis Results
Results are reported as the change in tumor volume, separately for growth and shrinkage component. The quantitative results are reported in voxels, mL and percentage relative the the volume of the structure segmented in the baseline scan.
The visualization of the analysis results includes the following components upon the completion of analysis:
|