Difference between revisions of "Modules:DicomToNRRD-3.6"
(→Usage) |
|||
(9 intermediate revisions by 3 users not shown) | |||
Line 43: | Line 43: | ||
**Achieva 2.5.3.3 | **Achieva 2.5.3.3 | ||
**Achieva 2.6.1.0 | **Achieva 2.6.1.0 | ||
+ | **Acheiva 2.6.3.4 | ||
**Intera 2.1.3.6 | **Intera 2.1.3.6 | ||
**Intera 2.6.3.5 | **Intera 2.6.3.5 | ||
*Siemens | *Siemens | ||
− | ** | + | **Trio B13 |
+ | **Trio B15 | ||
+ | **Trio B17 | ||
+ | **Verio B15V | ||
*GE | *GE | ||
− | ** | + | **SIGNA HDx14.0 |
− | + | **SIGNA HDxt 15.0 | |
+ | **DVMR 20.0M4 | ||
+ | **DVMR 20.1 | ||
+ | ====Command Line Usage==== | ||
A command line example for running the module is: | A command line example for running the module is: | ||
d:\Builds\Slicer3\lib\Slicer3\Plugins\Release\DicomToNrrdConverter.exe --inputDicomDirectory MyDicomDir --outputVolume MyNrrdImage.nhdr | d:\Builds\Slicer3\lib\Slicer3\Plugins\Release\DicomToNrrdConverter.exe --inputDicomDirectory MyDicomDir --outputVolume MyNrrdImage.nhdr | ||
+ | |||
+ | The module is currently set to quit and alert the user of gradients whose magnitudes are unreasonably small (greater than 0 and less than the smallGradientThreshold) via the '''smallGradientThreshold''' flag (default value for smallGradientThreshold: 0.2). This flag was created after encountering gradient vectors whose magnitudes were unusually small in Siemens Trio Tim B13 data due to incorrect metadata for diffusion gradient vector coordinate entries in the DICOM header public element tags. | ||
+ | |||
+ | '''For Siemens data:''' In event of incorrect metadata for diffusion gradient vector coordinates in the DICOM header public element tags, please set the '''useBMatrixGradientDirections''' flag. When the useBMatrixGradientDirections flag is set, gradient direction coordinates and b values are derived from the '''bMatrix''' DICOM header private element tag for each gradient. In Siemens DWI data, the b matrix elements are the product of the b value and unit gradient direction vector (column vector) multiplied by the transpose of the unit gradient direction vector. Therefore, for a given gradient direction, the unit gradient direction vector coordinates are the first column of the 3x3 unitary matrix from a singular value decomposition of its b matrix, while the b value is the trace of its b matrix. | ||
===Quick Tour of Features and Use=== | ===Quick Tour of Features and Use=== | ||
− | [[Image: | + | [[Image:DicomToNrrdConverter_wiki.png|thumb|right|280px|Input/Output panels]] |
When this module is run from Slicer UI, simply select the directories for '''Input Dicom Data''' and '''Output Directory''', enter the filename (without path name, but '''with''' extension, such as '''mydti.nrrd''') in the '''Output Filename''' field, and press "Apply" button. | When this module is run from Slicer UI, simply select the directories for '''Input Dicom Data''' and '''Output Directory''', enter the filename (without path name, but '''with''' extension, such as '''mydti.nrrd''') in the '''Output Filename''' field, and press "Apply" button. | ||
Line 123: | Line 134: | ||
--echo | --echo | ||
Echo the command line arguments (default: 0) | Echo the command line arguments (default: 0) | ||
+ | |||
+ | --useBMatrixGradientDirections | ||
+ | Fill the nhdr header with the gradient directions and bvalues computed | ||
+ | out of the BMatrix. Only changes behavior for Siemens data. (default: | ||
+ | 0) | ||
--useIdentityMeaseurementFrame | --useIdentityMeaseurementFrame | ||
Line 134: | Line 150: | ||
purposes only, the format is not fixed, and will likely change as | purposes only, the format is not fixed, and will likely change as | ||
debugging of new dicom formats is necessary. (default: 0) | debugging of new dicom formats is necessary. (default: 0) | ||
+ | |||
+ | --smallGradientThreshold <double> | ||
+ | If a gradient magnitude is greater than 0 and less than | ||
+ | smallGradientThreshold, then DicomToNrrdConverter will display an | ||
+ | error message and quit, unless the useBMatrixGradientDirections option | ||
+ | is set. (default: 0.2) | ||
--outputVolume <std::string> | --outputVolume <std::string> |
Latest revision as of 20:27, 14 March 2011
Home < Modules:DicomToNRRD-3.6Return to Slicer 3.6 Documentation
Module Name
DWI Dicom To NRRD
General Information
Module Type & Category
Type: Command line module
Category: Converters
Authors, Collaborators & Contact
- Author: Xiaodong Tao (with contribution from Vince Magnotta and Hans Johnson)
- Contact: taox @ research.ge.com
Module Description
This module converts diffusion weighted MR images in dicom series into Nrrd format for analysis in Slicer. This program has been tested on only a limited subset of DTI dicom formats available from Siemens, GE, and Phillips scanners. Work in progress to support dicom multi-frame data. The program parses dicom header to extract necessary information about measurement frame, diffusion weighting directions, b-values, etc, and write out a nrrd image.
Usage
Examples, Use cases & Tutorials
This module is typically used as the first step in diffusion weighted image analysis and tractography to convert diffusion weighted images in Dicom format into Nrrd format, which is recognized by Slicer3 as a legitimate diffusion weighted volume.
In the recent development, it is extended to act as a dicom series to nrrd file converted for non-diffusion-weighted images as well.
Supported DWI formats
- Philips scanner/software version combinations:
- Achieva 2.1.3.6
- Achieva 2.5.3.0
- Achieva 2.5.3.3
- Achieva 2.6.1.0
- Acheiva 2.6.3.4
- Intera 2.1.3.6
- Intera 2.6.3.5
- Siemens
- Trio B13
- Trio B15
- Trio B17
- Verio B15V
- GE
- SIGNA HDx14.0
- SIGNA HDxt 15.0
- DVMR 20.0M4
- DVMR 20.1
Command Line Usage
A command line example for running the module is:
d:\Builds\Slicer3\lib\Slicer3\Plugins\Release\DicomToNrrdConverter.exe --inputDicomDirectory MyDicomDir --outputVolume MyNrrdImage.nhdr
The module is currently set to quit and alert the user of gradients whose magnitudes are unreasonably small (greater than 0 and less than the smallGradientThreshold) via the smallGradientThreshold flag (default value for smallGradientThreshold: 0.2). This flag was created after encountering gradient vectors whose magnitudes were unusually small in Siemens Trio Tim B13 data due to incorrect metadata for diffusion gradient vector coordinate entries in the DICOM header public element tags.
For Siemens data: In event of incorrect metadata for diffusion gradient vector coordinates in the DICOM header public element tags, please set the useBMatrixGradientDirections flag. When the useBMatrixGradientDirections flag is set, gradient direction coordinates and b values are derived from the bMatrix DICOM header private element tag for each gradient. In Siemens DWI data, the b matrix elements are the product of the b value and unit gradient direction vector (column vector) multiplied by the transpose of the unit gradient direction vector. Therefore, for a given gradient direction, the unit gradient direction vector coordinates are the first column of the 3x3 unitary matrix from a singular value decomposition of its b matrix, while the b value is the trace of its b matrix.
Quick Tour of Features and Use
When this module is run from Slicer UI, simply select the directories for Input Dicom Data and Output Directory, enter the filename (without path name, but with extension, such as mydti.nrrd) in the Output Filename field, and press "Apply" button.
The module can also be run from command line to enable batch process. An example command line look like:
d:\Builds\Slicer3\lib\Slicer3\Plugins\Release\DicomToNrrdConverter.exe --inputDicomDirectory MyDicomDir --outputDirectory /scratch/Diffusion --outputVolume MyNrrdImage.nrrd
Development
Dependencies
This module depends only on the core "Volumes" module of slice for data IO.
Known Bugs
Usability Issues
Because different vendors used different private tags to store information related to diffusion weighting and documentation on how to interoperate this information is scarce, the current version support diffusion weighted images from GE, Siemens, and Philips scanners. For Siemens, both mosaic and split formats are supported. For Philips, both multi-slice and signal-slice formats are supported.
The current version also support non-diffusion weighted images from any vendors (that GDCM supports), in which case, the module acts as a dicom series to nrrd volume converter.
Source Code and Documentation
Source Code: DicomToNrrdConverter.cxx
XML Description: DicomToNrrdConverter.xml
Test: DicomToNrrdConverterTest.cxx
./lib/Slicer3/Plugins/DicomToNrrdConverter --help USAGE: ./lib/Slicer3/Plugins/DicomToNrrdConverter [--returnparameterfile <std::string>] [--processinformationaddress <std::string>] [--xml] [--echo] [--useIdentityMeaseurementFrame] [--writeProtocolGradientsFile] [--outputVolume <std::string>] [--outputDirectory <std::string>] [--inputDicomDirectory <std::string>] [--] [--version] [-h] Where: --returnparameterfile <std::string> Filename in which to write simple return parameters (int, float, int-vector, etc.) as opposed to bulk return parameters (image, geometry, transform, measurement, table). --processinformationaddress <std::string> Address of a structure to store process information (progress, abort, etc.). (default: 0) --xml Produce xml description of command line arguments (default: 0) --echo Echo the command line arguments (default: 0) --useBMatrixGradientDirections Fill the nhdr header with the gradient directions and bvalues computed out of the BMatrix. Only changes behavior for Siemens data. (default: 0) --useIdentityMeaseurementFrame Adjust all the gradients so that the measurement frame is an identity matrix. (default: 0) --writeProtocolGradientsFile Write the protocol gradients to a file suffixed by '.txt' as they were specified in the procol by multiplying each diffusion gradient direction by the measurement frame. This file is for debugging purposes only, the format is not fixed, and will likely change as debugging of new dicom formats is necessary. (default: 0) --smallGradientThreshold <double> If a gradient magnitude is greater than 0 and less than smallGradientThreshold, then DicomToNrrdConverter will display an error message and quit, unless the useBMatrixGradientDirections option is set. (default: 0.2) --outputVolume <std::string> Output filename (.nhdr) --outputDirectory <std::string> Directory holding the output NRRD format --inputDicomDirectory <std::string> Directory holding Dicom series --, --ignore_rest Ignores the rest of the labeled arguments following this flag. --version Displays version information and exits. -h, --help Displays usage information and exits. Description: Converts diffusion weighted MR images in dicom series into Nrrd format for analysis in Slicer. This program has been tested on only a limited subset of DTI dicom formats available from Siemens, GE, and Phillips scanners. Work in progress to support dicom multi-frame data. The program parses dicom header to extract necessary information about measurement frame, diffusion weighting directions, b-values, etc, and write out a nrrd image. For non-diffusion weighted dicom images, it loads in an entire dicom series and writes out a single dicom volume in a .nhdr/.raw pair. Author(s): Xiaodong Tao Acknowledgements: This work is part of the National Alliance for Medical Image Computing (NAMIC), funded by the National Institutes of Health through the NIH Roadmap for Medical Research, Grant U54 EB005149. Additional support for DTI data produced on Philips scanners was contributed by Vincent Magnotta and Hans Johnson at the University of Iowa.
More Information
Acknowledgement
Acknowledgements: This work is part of the National Alliance for Medical Image Computing (NAMIC), funded by the National Institutes of Health through the NIH Roadmap for Medical Research, Grant U54 EB005149. Additional support for DTI data produced on Philips scanners was contributed by Vincent Magnotta and Hans Johnson at the University of Iowa.
References
More information on Dicom format for diffusion weighted images on NA-MIC Wiki.