===Module Description=== | ===Module Description=== | ||
− | Module performs pixel-wise addition of two images. | + | Module performs pixel-wise addition of two images. The module automatically handles different resolution of the input images. The module supports input images of any data type. |
== Usage == | == Usage == | ||
− | Load the input volumes(images). The default setting of the | + | Load the input volumes(images). The default setting of the parameter Interpolation Setting is 1. For input images of the same size, this setting will work correctly. In general, its best to use input images of the same size for the addition operation. |
===Examples, Use Cases & Tutorials=== | ===Examples, Use Cases & Tutorials=== | ||
− | This module can be used for producing intermediate results that can then be | + | This module can be used for producing intermediate results that can then be as inputs to other modules. |
===Quick Tour of Features and Use=== | ===Quick Tour of Features and Use=== | ||
− | *"Inputs/Outputs:" This module requires two input volumes(images), and the specification of an output volume(image). The module produces | + | *"Inputs/Outputs:" This module requires two input volumes(images), and the specification of an output volume(image). The module produces an output image of the same size as the first input image. |
− | *"Parameters:" The module uses one parameter ''Interpolation Order''. The interpolation order sets the degree of B-spline interpolation to be performed on the second input image for re-sampling it to the same size as the first input image. The default setting is 1 | + | *"Parameters:" The module uses one parameter ''Interpolation Order''. The interpolation order sets the degree of B-spline interpolation to be performed on the second input image for re-sampling it to the same size as the first input image. The default setting is 1. |
== Development == | == Development == |
Latest revision as of 13:22, 27 April 2010
Home < Modules:AddImages-Documentation-3.6Return to Slicer 3.6 Documentation
Module Name
Filtering:Add
General Information
Module Type & Category
Type: CLI
Category: Base or (Filtering, Registration, etc.)
Authors, Collaborators & Contact
- Author: Bill Lorensen
- Contact: bill.lorensen at gmail.com
- Documentation: Harini Veeraraghavan
- Contact: veerarag at ge.com
Module Description
Module performs pixel-wise addition of two images. The module automatically handles different resolution of the input images. The module supports input images of any data type.
Usage
Load the input volumes(images). The default setting of the parameter Interpolation Setting is 1. For input images of the same size, this setting will work correctly. In general, its best to use input images of the same size for the addition operation.
Examples, Use Cases & Tutorials
This module can be used for producing intermediate results that can then be as inputs to other modules.
Quick Tour of Features and Use
- "Inputs/Outputs:" This module requires two input volumes(images), and the specification of an output volume(image). The module produces an output image of the same size as the first input image.
- "Parameters:" The module uses one parameter Interpolation Order. The interpolation order sets the degree of B-spline interpolation to be performed on the second input image for re-sampling it to the same size as the first input image. The default setting is 1.
Development
Dependencies
This module uses the ITK libraries.
Known bugs
Follow this link to the Slicer3 bug tracker.
Usability issues
Follow this link to the Slicer3 bug tracker. Please select the usability issue category when browsing or contributing.
Source code & documentation
Source Code:
Test Code:
More Information
Acknowledgment
This work is part of the National Alliance for Medical Image Computing (NAMIC), funded by the National Institutes of Health through the NIH Roadmap for Medical Research, Grant U54 EB005149. Information on the National Centers for Biomedical Computing can be obtained from National Centers for Biomedical Computing.