Difference between revisions of "Documentation/Nightly/Modules/GelDosimetry"
From Slicer Wiki
m (Text replacement - "\[http:\/\/www\.slicer\.org\/slicerWiki\/index\.php\/([^ ]+) ([^]]+)]" to "$2") |
|||
(4 intermediate revisions by one other user not shown) | |||
Line 9: | Line 9: | ||
{{documentation/{{documentation/version}}/module-section|Introduction and Acknowledgements}} | {{documentation/{{documentation/version}}/module-section|Introduction and Acknowledgements}} | ||
− | Authors: <b> | + | Authors: <b>Csaba Pinter</b> (PerkLab, Queen's University), Kevin Alexander (KGH, Queen's University), Jennifer Andrea (PerkLab, Queen's University), Mattea Welch (University of Toronto)<br> |
− | Contributors: | + | Contributors: John Schreiner (Kingston General Hospital)<br> |
Contacts: | Contacts: | ||
* Csaba Pinter, <email>csaba.pinter@queensu.ca</email> | * Csaba Pinter, <email>csaba.pinter@queensu.ca</email> | ||
+ | * Kevin Alexander, <email>Kevin.Alexander@krcc.on.ca</email> | ||
* [[Documentation/SlicerRT/HowToReportAnError|How to report an error]] | * [[Documentation/SlicerRT/HowToReportAnError|How to report an error]] | ||
License: [http://www.slicer.org/pages/LicenseText Slicer license]<br> | License: [http://www.slicer.org/pages/LicenseText Slicer license]<br> | ||
Line 19: | Line 20: | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/extension-section|Extension Description}} | {{documentation/{{documentation/version}}/extension-section|Extension Description}} | ||
+ | |||
{| | {| | ||
− | | | + | |
− | [[Image:GelDosimetry_Logo_128x128.png]] | + | |[[Image:GelDosimetry_Logo_128x128.png]] |
+ | |||
| | | | ||
* Gel dosimetry analysis is a tool used in commissioning new radiation techniques and to validate the accuracy of radiation treatment by enabling visual comparison of the planned dose to the delivered dose, where correspondence between the two dose distributions is achieved using embedded landmarks. Gel dosimetry is based on imaging chemical systems spatially fixed in gelatin, which exhibit a detectable change upon irradiation. This chemical change is related to the amount of radiation received and can be probed by several imaging techniques, allowing 3D dose information to be obtained. | * Gel dosimetry analysis is a tool used in commissioning new radiation techniques and to validate the accuracy of radiation treatment by enabling visual comparison of the planned dose to the delivered dose, where correspondence between the two dose distributions is achieved using embedded landmarks. Gel dosimetry is based on imaging chemical systems spatially fixed in gelatin, which exhibit a detectable change upon irradiation. This chemical change is related to the amount of radiation received and can be probed by several imaging techniques, allowing 3D dose information to be obtained. | ||
Line 27: | Line 30: | ||
* The extension depends on the SlicerRT general radiation therapy extension | * The extension depends on the SlicerRT general radiation therapy extension | ||
− | |||
|} | |} | ||
− | |||
− | |||
− | |||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/extension-section|Use Cases}} | {{documentation/{{documentation/version}}/extension-section|Use Cases}} | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | {| | |
| | | | ||
+ | == Gel dosimetry analysis workflow: == | ||
+ | # Loading planning image (PLANCT) and a planned dose distribution (PLANDOSE) | ||
+ | # Load an on-board imager cone beam CT scan (OBI) | ||
+ | # Register OBI to PLANCT | ||
+ | # Transform PLANDOSE using result transform (to OBI coordinate frame) | ||
+ | # Load 3D optical CT scan of the gel, or a 2D scan of the film. (MEASURED) | ||
+ | # Register MEASURED to OBI using fiducial marks, using rigid transform | ||
+ | # Transform MEASURED using result transform (to OBI coordinate frame) | ||
+ | # Load Percent Depth Dose data (two-column spreadsheet) | ||
+ | # Load experimental CALIBRATION 3D optical CT scan from VFF file | ||
+ | # Get mean optical densities from the central cylinder of the CALIBRATION volume | ||
+ | # Align PDD curve with the curve resulting from previous step | ||
+ | # Calibrate PDD data using RDF and electron MU values input by the user | ||
+ | # Fit polynomial on the optical density vs. dose curve (resulting from the aligned calibration curves) | ||
+ | # Perform a gamma, chi, etc. test between MEASURED and PLANDOSE, yielding another 3D volume COMPARISON | ||
+ | # Extract statistics from COMPARISON | ||
+ | |||
+ | | | ||
+ | [[File:GelDosimetryAnalysis_DataFlow_v06.png|thumb|720px|Gel dosimetry data flow diagram]] | ||
+ | |||
+ | |} | ||
+ | |||
+ | <br> | ||
+ | |||
{| | {| | ||
− | | | + | |[[File:20150605_Gamma_98percent.png|thumb|920px|Gel dosimetry screenshot]] |
− | + | ||
|[[File:GelDosimetryAnalysis_0.1.2_PddCurveAlignment_Small.png|thumb|400px|Pdd aligment curve screenshot]] | |[[File:GelDosimetryAnalysis_0.1.2_PddCurveAlignment_Small.png|thumb|400px|Pdd aligment curve screenshot]] | ||
− | + | <br> | |
− | + | [[File:GelDosimetryAnalysis_0.1.2_OdVsDoseCurve_Small.png|thumb|400px|Calibration curve screenshot]] | |
|} | |} | ||
Line 66: | Line 73: | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/extension-section|Tutorials}} | {{documentation/{{documentation/version}}/extension-section|Tutorials}} | ||
− | * | + | * [[File:WC2015_Gel_slicelet_tutorial_final.pdf|World Congress 2015 Gel Dosimetry Tutorial]] |
+ | ** [http://slicer.kitware.com/midas3/download/item/205391/WC2015_Gel_Slicelet_Dataset.zip Dataset] | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
Line 74: | Line 82: | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/extension-section|References}} | {{documentation/{{documentation/version}}/extension-section|References}} | ||
+ | * Alexander, K. M., et al. "Implementation of an efficient workflow process for gel dosimetry using 3D Slicer." Journal of Physics: Conference Series. Vol. 573. No. 1. IOP Publishing, 2015. | ||
+ | ** Please cite this when you refer to Gel Dosimetry in your publication | ||
+ | * Pinter, C., et al. "Performing radiation therapy research using the open-source SlicerRT toolkit." World Congress for Medical Physics and Biomedical Engineering, 2015 | ||
+ | * C. Pinter, A. Lasso, A. Wang, D. Jaffray and G. Fichtinger, [http://perk.cs.queensu.ca/sites/perk.cs.queensu.ca/files/Pinter2012_0.pdf "SlicerRT – Radiation therapy research toolkit for 3D Slicer"], Med. Phys., 39(10) pp. 6332-6338, 2012 | ||
+ | ** Please cite the following paper when referring to SlicerRT in your publication | ||
<!-- | <!-- | ||
− | |||
− | |||
− | |||
<pre> | <pre> | ||
@ARTICLE{Pinter2012, | @ARTICLE{Pinter2012, | ||
Line 90: | Line 100: | ||
</pre> | </pre> | ||
--> | --> | ||
− | |||
− | |||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/extension-section|Information for Developers}} | {{documentation/{{documentation/version}}/extension-section|Information for Developers}} |
Latest revision as of 02:31, 27 November 2019
Home < Documentation < Nightly < Modules < GelDosimetry
For the latest Slicer documentation, visit the read-the-docs. |
Introduction and Acknowledgements
Authors: Csaba Pinter (PerkLab, Queen's University), Kevin Alexander (KGH, Queen's University), Jennifer Andrea (PerkLab, Queen's University), Mattea Welch (University of Toronto)
Contributors: John Schreiner (Kingston General Hospital)
Contacts:
- Csaba Pinter, <email>csaba.pinter@queensu.ca</email>
- Kevin Alexander, <email>Kevin.Alexander@krcc.on.ca</email>
- How to report an error
License: Slicer license
Download/install: install 3D Slicer, start 3D Slicer, open the Extension Manager, install SlicerRT extension, restart, install the GelDosimetry extension
Extension Description
Use Cases
Gel dosimetry analysis workflow:
|
|
Tutorials
Similar Extensions
- SlicerRT: GelDosimetry uses several modules from the SlicerRT extension
References
- Alexander, K. M., et al. "Implementation of an efficient workflow process for gel dosimetry using 3D Slicer." Journal of Physics: Conference Series. Vol. 573. No. 1. IOP Publishing, 2015.
- Please cite this when you refer to Gel Dosimetry in your publication
- Pinter, C., et al. "Performing radiation therapy research using the open-source SlicerRT toolkit." World Congress for Medical Physics and Biomedical Engineering, 2015
- C. Pinter, A. Lasso, A. Wang, D. Jaffray and G. Fichtinger, "SlicerRT – Radiation therapy research toolkit for 3D Slicer", Med. Phys., 39(10) pp. 6332-6338, 2012
- Please cite the following paper when referring to SlicerRT in your publication
Information for Developers
- N/A