Difference between revisions of "Documentation/4.1/Modules/OpenIGTLinkIF"
(Prepend documentation/versioncheck template. See http://na-mic.org/Mantis/view.php?id=2887) |
|||
(6 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | <noinclude>{{documentation/versioncheck}}</noinclude> | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-header}} | {{documentation/{{documentation/version}}/module-header}} | ||
Line 52: | Line 53: | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|Panels and their use}} | {{documentation/{{documentation/version}}/module-section|Panels and their use}} | ||
− | |||
{| | {| | ||
Line 67: | Line 67: | ||
***Status: Checkbox to turn on/off the server. | ***Status: Checkbox to turn on/off the server. | ||
***Hostname: The TCP/IP host name of the remote OpenIGTLink server (only available if the connector is client) | ***Hostname: The TCP/IP host name of the remote OpenIGTLink server (only available if the connector is client) | ||
− | ***Port: The TCP/IP port number of the remote OpenIGTLink (if the connector is configured as a client) or port number of this OpenIGTLink connector (if the connector is configured as a server). | + | ***Port: The TCP/IP port number of the remote OpenIGTLink (if the connector is configured as a client) or the port number of this OpenIGTLink connector (if the connector is configured as a server). |
| align="right"| | | align="right"| | ||
[[Image:Slicer4-OpenIGTLinkIF-Connectors.png|thumb|200px|Connector Properties]] | [[Image:Slicer4-OpenIGTLinkIF-Connectors.png|thumb|200px|Connector Properties]] | ||
Line 73: | Line 73: | ||
| | | | ||
* I/O Configuration panel: The list of nodes that are used to receive/send data through OpenIGTLink connectors. | * I/O Configuration panel: The list of nodes that are used to receive/send data through OpenIGTLink connectors. | ||
− | **IN: | + | **IN: The list of incoming data (node names) received through the connector node. |
− | **OUT: | + | **OUT: The list of outgoing data (node names) sent through the connector node. |
| align="right"| | | align="right"| | ||
[[Image:Slicer4-OpenIGTLinkIF-IOConfiguration.png|thumb|200px|I/O Configuration Tree interface]] | [[Image:Slicer4-OpenIGTLinkIF-IOConfiguration.png|thumb|200px|I/O Configuration Tree interface]] | ||
Line 89: | Line 89: | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|References}} | {{documentation/{{documentation/version}}/module-section|References}} | ||
− | # | + | #Tokuda J, Fischer GS, Papademetris X, Yaniv Z, Ibanez L, Cheng P, Liu H, Blevins J, Arata J, Golby A, Kapur T, Pieper S, Burdette EC, Fichtinger G, Tempany CM, Hata N, OpenIGTLink: An Open Network Protocol for Image-Guided Therapy Environment, Int J Med Robot 2009; 5(4):423-34. |
<!-- ---------------------------- --> | <!-- ---------------------------- --> |
Latest revision as of 07:23, 14 June 2013
Home < Documentation < 4.1 < Modules < OpenIGTLinkIF
For the latest Slicer documentation, visit the read-the-docs. |
Introduction and Acknowledgements
This work is supported by NA-MIC, NCIGT, and the Slicer Community. This work is partially supported by NIH 1R01CA111288-01A1 "Enabling Technologies for MRI-Guided Prostate Interventions" (PI: Clare Tempany), P01-CA67165 "Image Guided Therapy" (PI: Ferenc Joelsz) and AIST Intelligent Surgical Instrument Project (PI: Makoto Hashizume, Site-PI: Nobuhiko Hata). | |||||
|
Module Description
The OpenIGTLink Interface Module is a program module for network communication with external software / hardware using OpenIGTLink protocol. The module provides following features:
|
Supported Devices
See here for a list of supported devices.
Use Cases
- MRI-compatible Robotic Systems (BRP Project between BWH, Johns Hopkins University and Acoustic MedSystems Inc., "Enabling Technologies for MRI-Guided Prostate Interventions")
- The 3D Slicer was connected to an MRI-compatible Robot, using OpenIGTLinkIF to send target position from Slicer to the robot and to send the actual robot position (based on sensor information) from the robot back to Slicer. Slicer was also connected to the MRI scanner. Scan plane position and orientation were prescribed in Slicer and transmitted to the scanner for controlling real-time image acquisition and for transferring the acquired images from the MR scanner back into Slicer for display.
- Neurosurgical Robot Project(Nagoya Institute of Technology, Japan)
- The 3D Slicer was connected to the optical tracking system (Optotrak, Northern Digital Inc.) to acquire current position of the end-effector of the robot.
Tutorials
Please follow the OpenIGTLink IF Tutorial presentation file.
Panels and their use
|
|
|
Similar Modules
N/A
References
- Tokuda J, Fischer GS, Papademetris X, Yaniv Z, Ibanez L, Cheng P, Liu H, Blevins J, Arata J, Golby A, Kapur T, Pieper S, Burdette EC, Fichtinger G, Tempany CM, Hata N, OpenIGTLink: An Open Network Protocol for Image-Guided Therapy Environment, Int J Med Robot 2009; 5(4):423-34.
Information for Developers
Section under construction. |