Difference between revisions of "Documentation/4.2/Extensions/PkModeling"
From Slicer Wiki
(Nightly -> 4.2) |
|||
Line 1: | Line 1: | ||
− | |||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
− | {{documentation/{{documentation/version}}/ | + | {{documentation/{{documentation/version}}/module-header}} |
+ | <!-- ---------------------------- --> | ||
+ | |||
+ | <!-- ---------------------------- --> | ||
+ | {{documentation/{{documentation/version}}/module-section|Introduction and Acknowledgements}} | ||
+ | {{documentation/{{documentation/version}}/module-introduction-start|{{documentation/modulename}}}} | ||
+ | {{documentation/{{documentation/version}}/module-introduction-row}} | ||
+ | Extension: [[Documentation/{{documentation/version}}/Extensions/PkModeling|PkModeling]]<br> | ||
+ | Acknowledgments: | ||
+ | This work is part of the National Alliance for Medical Image Computing (NA-MIC), funded by the National Institutes of Health through the NIH Roadmap for Medical Research.<br> | ||
+ | Implementation of the pharmacokinetics modeling was contributed by Yingxuan Zhu and Jim Miller from GE Research.<br> | ||
+ | Author: Yingxuan Zhu, Jim Miller ({{collaborator|name|ge}})<br> | ||
+ | Contact: Yingxuan Zhu, <email>zhuyi@ge.com</email><br> | ||
+ | {{documentation/{{documentation/version}}/module-introduction-row}} | ||
+ | {{documentation/{{documentation/version}}/module-introduction-logo-gallery | ||
+ | |{{collaborator|logo|ge}}|{{collaborator|longname|ge}} | ||
+ | |{{collaborator|logo|namic}}|{{collaborator|longname|namic}} | ||
+ | }} | ||
+ | |||
+ | {{documentation/{{documentation/version}}/module-introduction-end}} | ||
+ | |||
+ | <!-- ---------------------------- --> | ||
+ | {{documentation/{{documentation/version}}/module-section|Module Description}} | ||
+ | {| | ||
+ | | | ||
+ | PkModeling (Pharmacokinetics Modeling) calculates quantitative parameters from Dynamic Contrast Enhanced DCE-MRI images. This module performs two operations: | ||
+ | # Converts signal intensities to concentration values. The concentration values are used to calculate quantitative parameters. | ||
+ | # Calculates quantitative parameters from concentration values. These parameters include: | ||
+ | ;Ktrans: Volume transfer constant between blood plasma and EES (extracellular-extravascular space) at each voxel | ||
+ | ;Ve: Fractional volume for extracellular space at each voxel | ||
+ | ;MaxSlope: Maximum slope in the time series curve of each voxel | ||
+ | ;AUC: Area under the curve of each voxel, measured from bolus arrival time to the end time of interval, normalized by the AUC of the AIF | ||
+ | |||
+ | |} | ||
+ | |||
+ | <!-- ---------------------------- --> | ||
+ | {{documentation/{{documentation/version}}/module-section|Use Cases}} | ||
+ | {| | ||
+ | |} | ||
+ | |||
+ | <!-- ---------------------------- --> | ||
+ | {{documentation/{{documentation/version}}/module-section|Tutorials}} | ||
+ | |||
+ | <!-- ---------------------------- --> | ||
+ | {{documentation/{{documentation/version}}/module-section|Panels and their use}} | ||
+ | |||
+ | {| | ||
+ | |[[Image:PkModelingUI061912.png|thumb|340px|PkModeling]] | ||
+ | | | ||
+ | * '''IO''' | ||
+ | ** '''Input:''' 4D DCE-MRI data; 3D mask showing the location of the arterial input function. | ||
+ | ** '''Output:''' 4 volumes showing the maps of quantitative parameters: ktrans, ve, maximum slope, and area under the curve (AUC). | ||
+ | * '''Parameters''' | ||
+ | ** '''PkModeling''': | ||
+ | *** T1 Blood Value | ||
+ | *** T1 Tissue Value | ||
+ | *** Relaxivity Value | ||
+ | *** Hematocrit Value. Volume percentage of red blood cells in blood. | ||
+ | *** AUC Time Interval Value: Time interval for AUC calculation | ||
+ | ** '''Acquisition''': | ||
+ | *** TR Value: Repetition time, | ||
+ | *** TE Value: Echo time, | ||
+ | *** FA Value: Flip angle, | ||
+ | *** Time Axis: Time series. | ||
+ | |||
+ | |} | ||
+ | |||
+ | <!-- ---------------------------- --> | ||
+ | {{documentation/{{documentation/version}}/module-section|Similar Modules}} | ||
+ | * [[Documentation/{{documentation/version}}/Modules/MultiVolumeExplorer|MultiVolumeExplorer]] | ||
+ | * [[Documentation/{{documentation/version}}/Modules/MultiVolumeImporter|MultiVolumeImporter]] | ||
+ | |||
+ | <!-- ---------------------------- --> | ||
+ | {{documentation/{{documentation/version}}/module-section|References}} | ||
+ | * Knopp MV, Giesel FL, Marcos H et al: Dynamic contrast-enhanced magnetic resonance imaging in oncology. Top Magn Reson Imaging, 2001; 12:301-308. | ||
+ | * Rijpkema M, Kaanders JHAM, Joosten FBM et al: Method for quantitative mapping of dynamic MRI contrast agent uptake in human tumors. J Magn Reson Imaging 2001; 14:457-463. | ||
+ | |||
+ | <!-- ---------------------------- --> | ||
+ | {{documentation/{{documentation/version}}/module-section|Information for Developers}} | ||
+ | {{documentation/{{documentation/version}}/module-developerinfo}} | ||
+ | |||
+ | <!-- ---------------------------- --> | ||
+ | {{documentation/{{documentation/version}}/module-footer}} | ||
+ | [[Category:Documentation/{{documentation/version}}/Modules/Quantification]] | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> |
Revision as of 19:51, 2 November 2012
Home < Documentation < 4.2 < Extensions < PkModeling
Introduction and Acknowledgements
Extension: PkModeling | |||||
|
Module Description
PkModeling (Pharmacokinetics Modeling) calculates quantitative parameters from Dynamic Contrast Enhanced DCE-MRI images. This module performs two operations:
|
Use Cases
Tutorials
Panels and their use
|
Similar Modules
References
- Knopp MV, Giesel FL, Marcos H et al: Dynamic contrast-enhanced magnetic resonance imaging in oncology. Top Magn Reson Imaging, 2001; 12:301-308.
- Rijpkema M, Kaanders JHAM, Joosten FBM et al: Method for quantitative mapping of dynamic MRI contrast agent uptake in human tumors. J Magn Reson Imaging 2001; 14:457-463.
Information for Developers
Section under construction. |