Difference between revisions of "Documentation/4.1/Modules/MultiVolumeImporter"
From Slicer Wiki
(Created page with '{{documentation/underconstruction}} {{ambox | type = protection | image = 40px|alt=Work in progress | text = WARNING: This module is Work in Progress, …') |
|||
Line 53: | Line 53: | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|Panels and their use}} | {{documentation/{{documentation/version}}/module-section|Panels and their use}} | ||
+ | |||
+ | {|style="width: 100%" | ||
+ | | | ||
+ | * '''Basic settings''' | ||
+ | * '''Advanced settings''' | ||
+ | | align="right" | | ||
+ | {| | ||
+ | [[Image:Slicer4-MultiVolumeImporter_panel1.png|Basic settings panel with the "Input data type" dropbox expanded]] | ||
+ | | | ||
+ | [[Image:Slicer4-MultiVolumeImporter_panel2.png|Advanced settings panel]] | ||
+ | |} | ||
+ | |||
+ | |} | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> |
Revision as of 15:45, 1 May 2012
Home < Documentation < 4.1 < Modules < MultiVolumeImporterPage under construction. |
WARNING: This module is Work in Progress, which means:
|
Introduction and Acknowledgements
This work is supported by NA-MIC, NAC, NCIGT, and the Slicer Community. This work is partially supported by the following grants: P41EB015898, P41RR019703, R01CA111288 and U01CA151261. | |||||||||||
|
Module Description
This module provides support for importing multivolume (multiframe) data.
Use Cases
Most frequently used for these scenarios:
- importing a DICOM dataset that contains multiple frames that can be separated based on some tag (e.g., DCE MRI data, where individual temporally resolved frames are identified by Trigger Time tag (0018,1060)
- importing multiple frames defined in the same coordinate frame, saved as individual volumes in NRRD, NIfTI, or any other image format supported by 3D Slicer
Tutorials
- Sample datasets are available:
- anonymized prostate DCE MRI DICOM series
- File:Cardiac ECGg CT.tgz (ECG-gated contrast-enhanced cardiac CT) (use "User-defined non-DICOM" parameter option to load it into MultiVolumeImporter). Short movie
Panels and their use
|
|
Similar Modules
Once the multivolume dataset is loaded, it can be viewed and further explored using MultiVolumeExplorer module..
References
- Development of this module was initiated at the 2012 NA-MIC Project week at SLC (see http://wiki.na-mic.org/Wiki/index.php/2012_Project_Week:4DImageSlicer4)
Information for Developers
Section under construction. |
Known issues that won't be resolved
- bug 1841: multivolumes that contain less than 7 frames will not be saved correctly and the scene containing such objects will not be loaded correctly by Slicer (limitation of the NRRD IO for DWI)
Features to be implemented
- integrate MV importer as a DICOM module plugin
Features under consideration
- should DWI node be a child under the MV hierarchy?
- import multivolumes from ITK 4d images